Get complete information related to latest Fire Bitter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Bitter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Bitter Tenders.
Tender For repair, replacement and maint of water disinfectors for fire fighting system, jockey pump, diesel engine driven pump, starter panel, soft starter, star delta starters with other miscellaneous items and comp maint/repair of fmr type stp at af stn digaru.
Tender For repair, maintenance, and installation of plant/ systems/equipments (version 2) - npcil office cum transit accom at noida; as per scope of work; as per scope of work- operation and maintenance of various systems, equipment and fittings and supply of items at npcil office cum transit accommodation at noida - 1.1 providing supervisory services for operation & maintenance activity of office cum transit accommodation for o&m work of 11 kv/415v/240v systems, domestic water / fire water/ r.o. water/, air conditioners, water coolers, d.g sets, lighting systems, earth pits, , telephone. lines distribution systems, maintenance of lawns, flowerpots, rectification of deficiencies related to civil work like plumbing, carpentry / masonry work and office work etc. cleaning of underground water tanks, and overhead water tanks. regular check of lighting system of the building and repair and replacement of bulb, choke, holder starter and office work etc. one activity shall be considered completed by deputing one highly skilled manpower as per qualification given in tech. spec. for 9 hours in a day as per work requirement. due to sensitivity of nature of work required round the clock 1.1 highly skilled supervisor will be available round the clock for any instance and requirement as the case may be. 1.2 providing services of technician in skilled category round the clock for o & m activity at noida office cum transit accommodation for following activities :- (i) operation & maintenance of 11 kv system/equipment & transformer:- cleaning and area up keeping of 11 kv switch gear panel and transformer and replacement of silica gel in 315 kva transformer if colour changes. ht drop out fuse and condition monitoring of complete switch gear area, 315 kva transformer oil level in conservator will be checked in one month. the oil level must be maintained between 25%-75%, if it reduces it should be topped up by new tested insulating oil of hv grade per is-335. bushing are to be examined for crack and dirt deposit and are to be cleaned or replaced as necessary once in six months or earlier if required. noise/humming sound, temperature rise (over heating) and crack in bituminous compound once in a month, general cleaning of the transformer to keep it free from dust and soot s quarterly or as required. (ii) preventive maintenance of two (02) nos. 415 volts air circuit breaker, 11 kv vcb (01 nos.) and switch gear area up keeping. the contractor is also responsible for maintaining 230 volts ac distribution systems in healthy condition. the scope of work includes maintenance of db s panels, & switchgear to ensure the functioning of fan, light, distribution of electricity within noida office cum transit accommodation building. the required spares shall be provided by npcil however consumables & hard wares e.g. lubricant, petroleum jelly, tb nut bolt, lugs etc shall be provided by contractor. (iii) operation & maintenance of domestic water/fire water system: the scope of work includes operation of bore well to maintain fire water tank level. preventive maintenance of domestic and fire water system, routine testing of fire water hydrants/pumps both diesel operated and electrical pumps. dewatering and cleaning of underground fire water tank and domestic water tank six monthly. (iv) cleaning of 2 no s of overhead fire tank of 5000 liter capacity and one no. domestic water overhead tank of capacity 5000 liter and one number of solar water tank six monthly, servicing and lubrication of 2 number of domestic water pump, 3 no. sump pump. servicing and lubrication of jockey pump, main hydrant pump, fire engine pump. the required all spares parts, hardware s e.g. lubricant, petroleum jelly nut bolt, gasket etc. shall be provided by contractor. (v) operation and maintenance of solar water heating system will require weekly cleaning of solar water panel, heater replacement and maintaining temperature with heater, repair and replacement of rubber
Tender For maintenance painting steel structural of hup buildings(old and new) for the year 2024-25 - painting the steel structural works such as columns, trusses, purlins, tie beams, bracings, vg clamps, grattings etc with two coat enamel paint (two different colours) over a coat of marine primer of approved quality after through surface preparation at all heights & levels including all cost and conveyance of materials, labour charges, loading unloading charges, hire charges for tools and plants, providing necessary scaffolding & covered of machinery with tarpalin , etc complete as per standard specification. (paint make: berger/ asian/nerolac/ ici or equivalent make ) (all the materials, tools & plants, tarpaulin etc required for the above shall be supplied by the contractor), supply fabrication and erection of steel structures by welded or bolted in built up /single sections for trusses, latice beams , purlins,ties, bracings etc for repair/maintenance/petty new works with ms angles, chanels, joists,plates etc including conveyance of all materials, loading & unloading charges, all labour charges, cost of consumables, applying one coat of marine primer , hire charges for tools and plants,providing temporary support for adjoining structures, dismantling and removing damaged structures etc complete as per standard specification. ( ms items vizaku, jindal,sale , tata or equivalent make with isi mark), supplying and fixing ac corrugated roofing / side clading sheet fixed with suitable size zinc phosphated galvanised and polymer coated j or l bolts and nuts and washers with necessarty overlap of 150mm at ends including cost and conveyance of all materials, loading & unloading charges, all labour charges, hire charges for tools and plants, dismantling and removing existing damaged roof sheets, dismantling and replacing the sheets of nearest bay for easiness of the work if necessary, providing necessary scaffolding / safety arrangement equipments for the work etc complete as per standard specification. (ac sheet make: everest/ ramco or equivalent with isi mark and roof bolts aargee/ katalyst make), supplying and fixing poly carbonate fully corrugated sheet clear / uv stabilised diffuser type having minimum thickness 1.80 mm with width of 1050 mm & length of 3.00 m to suit with fully corrugated asbestos cement roofing sheet for roof & side clading, fixed with suitable size zinc phosphated galvanised and polymer coated j or l bolts, nuts & washers with necessarty overlap of 150mm at ends including cost & conveyance of all materials , loading & unloading charges, all labour charges, hire charges for tools and plants, dismantling and removing existing damaged roof/ side clading sheets, providing necessary scaffolding / safety arrangement equipments for the work etc complete as per standard specification. (polycarbonite sheet make lotus/everest/tufflite), supplying and fixing ac corrugated ridge with zinc phosphated galvanised and polymer coated j or l bolts, nuts, washer & cap at all heights and levels including cost and,conveyance of all materials, loading & unloading charges ,all labour charges, hire charges for tools and plants, providing necessary scaffolding/ safety arrangement equipments for the work etc complete as per standard specification. (ac corrugated ridge make:- everest, vishka, ramco make ), mssupplying and fixing of moulded / pultruded frp grttings panel using isophthailic fire retardent grade resin, grattings shuld be square mesh size 35-50mm, height / depth 35- 50mm, rib thickness 5-8 mm with necessary accessories like ss clamps with nuts & bolts of pannel size 1000mm x 1000 mm including cost and conveyance of materials, loading unloading charges, hire charges for tools & plants, dismantling and removing damaged gi gratings , making nearest structures to suit for fixing new gratings, etc.complete as per standard specifications, supply and fixing zinc phosphated galvanised a