Web Analytics Made Easy - StatCounter

Fire Detector Tenders

Get complete information related to latest Fire Detector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Detector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Detector Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39437100 Due date: 19 Mar, 202519 Mar, 2025 90.00 Lacs
Tender For comprehensive maintenance of automatic fire detector, fire alarm and fire fighting system complete including control wiring, pipelines, valves, hydrants, pumps and motors at various otm and techinical accommodations under ge nw kunjali

State Government

CTN :39285787 Due date: 03 Mar, 202503 Mar, 2025 6.09 Lacs
Tender For corrigendum : providing and fixing of fire detector and smoke detector with alarm at 132 kv substation malwan under electy. trans. division - fatehpur

Central Government/Public Sector

CTN :39403505 Due date: 12 Mar, 202512 Mar, 2025 NA
Tender For supply of remote controlled water cum foam monitor

CTN :39403462 Due date: 03 Mar, 202503 Mar, 2025 NA
Tender For supply of regulator sub-assy,stl brs,161kg cm2,ctr , fire detector assy,141degc,ctr,nifps , valve assy,stemactd,ss,3 8in,0-21bar,ctr , valve,non rtrn,brs,g1 2,10bar,ctr,nifps , lamp,indctng,led,220vdc,grn,ctr,nifps , lamp,indctng,led,220vdc,red,ctr,nifps , hose pipe assembly,pvc,1 4inx1.25m,ctr , hose pipe assembly,pvc,3.8inx0.9m,ctr , switch assy,prsr mntr,ss,ctr,nifps , cable,fire srvl,1.5mm2,4c,shld,cu,ctr , limit switch asy set,16a,g02,g03,g04,ctr

Central Government / Public Sector

CTN :39383731 Due date: 04 Mar, 202504 Mar, 2025 NA
Tender For supply of port. oscillating water cum foam monitor , medium expansion foam generator, portable

Central Government/Public Sector

CTN :39370335 Due date: 10 Mar, 202510 Mar, 2025 NA
Tender For supply of triple purpose hand controlled branch , trolley foam , monitor cum foam water , the evacuation rescue chairs (carrying/transport chair) , hand held forcible entry tools (crow bar) , battery operated combitool

State Government

CTN :39360037 Due date: 22 Feb, 202522 Feb, 2025 NA
Tender For aqua foam monitor

CTN :39069622 Due date: 21 Feb, 202521 Feb, 2025 NA
Tender For corrigendum : supply of trailer mounted water cum foam monitor , water cum foam monitor

CTN :39336670 Due date: 07 Mar, 202507 Mar, 2025 84.51 Lacs
Tender For supply of supply of (e&m) item-, supplying of one number 3.5c x 300 sq.mm pvc insulated and pvc sheathed/xipe al. armoured conductor power cable of 1.1 kv grade of following ways complete etc as reqd., supplyof 2 kg hfc 227 ca/fk-5-1-12 with 10 mtr minimum heat sensing tube fire suppression system. clean agent hfc 227 ca/fk-5-1-12 dlp (direct low pressure) with zero ozone depletion potential. container along with valve assembly: clean agent hfc 227 ca/fk-5-1-12 direct complete as reqd operating pressure is 15 bar at 20 degree. sensor tube automatic fire suppression system, made by special modified polyamide double layered color blue/black/red, high grade hr quality, stabilized, inner diameter 4mm.outer diameter 6mm, sensor tubing hr blue/black/red in mtr. senso tube uv resistance with pressurization of tube using nitrogen gas. the hst conductive, non-corrosive and flexible. operating pressure: 15 bar end of line plug-maximum working pressure 20 bar. t connections., pressure switch. pressure valve - direct low pressure type with inbuilt pressure gauge, integrated ball valve for open/ close within the valve body. reed switch to monitor the valve position using the reed switch relay to indicate valve open/close position. power back up for monitoring panel- 12v, 7.2 ah smf batteries (2 nos) end line adopter. 2x1.5 sq. mm pvc insulated pvc seethed copper conductor single core cable wire in meter. required compelete system certification that is equivalent to lpcb standard equivalent to lps 1666: issue 1.0 with indian nabl. lab report., supply of low pressure is 16018 45 itr trolley mounted water mist & caf fire extinguisher with following specifications: water mist & caf fire extinguisher having fire rating 204, 2338 and dielectric test on is: 16018: 2012 (c1.6.8) 36kv at 1 meter distance, with standard afff 3% compound, confirming to is 4989. extinguishing gun stainless steel 1-2 kg approx weight with nabl test report. dual nozzle jet mode to spray mode by twisting of nozzle. suitable for all classes of fire a. b and e. pressure vessel with 45 liter nilling capacity. compressed air cylinder 6 liter 300 bar cylinder which can be inounted on universal air cylinder holder capable of holding these cylinders, length of hose 5 meter, the cylinder should be of red color with powder coating as per is standards the paint should confirm to is: 5:2007 shade 538., cylinders. lancing distance of gun 3-15 meter, flow rate 42 to 50 liter per second. system test: tested from nabl lab/erda, 1) content-water, foam, 2) gun mode jet and spray., supply & foxing of 100 watt led highway light suitable for 120 to 300v of cct(k) $700 lumen efficacy >130, cri minimum 70, mech, impact protection code above ik.08 having pic housing luminaire for enhanced uniform illumination and with ip66/65 protection i/c connection ete complete as reqd.,

Central Government/Public Sector

CTN :39341698 Due date: 07 Mar, 202507 Mar, 2025 20.00 Lacs
Tender For special repairs cum addition alteration to fire detectors and fire alarm system in building no p19 and p 232 in technical area at npol kochi
 Loading, Please wait...

Connect us via What's Up