Web Analytics Made Easy - StatCounter

Fire Fighting Equipment Tenders

Get complete information related to latest Fire Fighting Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Fighting Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Fighting Equipment Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government / Public Sector

CTN :39513413 Due date: 27 Mar, 202527 Mar, 2025 NA
Tender For corrigendum : supply of chassis mounted fire fighting equipment trailer trolley mounted fire fighting equipment

State Government

CTN :39733658 Due date: 25 Mar, 202525 Mar, 2025 12.21 Lacs
Tender For construction of urban health and wellness centre under abhim at school line new pahargaon under cd-ii apwd under eandm division apwd, prothrapur sw providing iei, fire fighting equipments and solar photo voltaic power generation system

Central Government/Public Sector

CTN :39751894 Due date: 07 Apr, 202507 Apr, 2025 30.00 Lacs
Tender For repair/replacement and maintenance of fire fighting equipments including fire alarm at hospital building under age (i) asvini, colaba, mumbai

Central Government/Public Sector

CTN :39686446 Due date: 04 Apr, 202504 Apr, 2025 15.00 Lacs
Tender For annual comprehensive maintenance of dg sets, glow sign board, fire fighting equipments and other miscellaneous works under ge i r and d kanpur

Central Government/Public Sector

CTN :38048681 Due date: 24 Mar, 202524 Mar, 2025 NA
Tender For bid to ras corrigendum : supply of fire suppression foam (afff concentrate for fire fighting) as per is 4989 (q3)

CTN :39724243 Due date: 15 Apr, 202515 Apr, 2025 NA
Tender For rate contract for the year 2025-26 for supply of electrical spares hardware material tand p fire fighting equipment and accessories required for maintenance and construction works in grid sub station and transmission lines

CTN :39713931 Due date: 24 Mar, 202524 Mar, 2025 19.86 Lacs
Tender For operation and maintenance of sub-station equipment i/c dg sets, maintenance of electrical installation and fans, fire fighting equipment, ups system at incp, south block, new delhi. (sh: comprehensive maintenance and operation of cctv, access control system and fire alarm system.)

CTN :39767801 Due date: 27 Mar, 202527 Mar, 2025 4.14 Lacs
Tender For annual plan-fire fighting equipments to alissery ,alappuzha mcf amp allied electrical works,-under alappuzha municiplity.-general electrical work

CTN :39574379 Due date: 25 Mar, 202525 Mar, 2025 NA
Tender For corrigendum : supply of fire suppression foam (afff concentrate for fire fighting) as per is 4989 (q3)

CTN :39361727 Due date: 26 Mar, 202526 Mar, 2025 11.83 Lacs
Tender For corrigendum : tn-23018 supply of fire fighting equipment and spares, kstps, kota. - supply of fire-fighting equipments and spares for kstps, kota, discharge tube for dcp 5kg. fire extinguisher (18" ft. hose length) cartridge type, discharge tube for dcp 10kg. fire extinguisher (24" ft. hose length) cartridge type, hose with horn for co2 extinguisher 22.5 kg (5 mtr. hose length) hose is connected with end connection on both side. co2 gas is discharged through this hose. one end is connected to discharge horn., hose with horn for co2 extinguisher 4.5 kg (1 mtr. hose length) hose is connected with end connection on both side. co2 gas is discharged through this hose. one end is connected to discharge horn., discharge tube for 25 kg dcp wire braided hose (3 meter length), supply of ss304 seat valve assembly with rubber washer for 63mm hydrant valve , as base plate sheet (metallic) with base plate check nut, with neoprene rubber wash- er for spindle., supply of c.i is: 210 hand wheel for 63mm hydrant valve, supply of q.b detector 1/2" size 79deg it operates as a valve by allowing the flow of water contained in a fire qbd system when the heat sensitive element (glass bulb or fusible link) is operated., supply of ss304 63mm female outlet for 63mm hydrant valve, supply of ss304 63mm bonnet for 63mm hydrant valve, supply of ss304 63mm spindle for 63mm hydrant valve, discharge tube with nozzle for foam 9 ltr. fire extinguisher (1.5 mtr. hose length), insulated hand gloves with working voltage of 17000 volts and proof voltage 25000 volts as per is 4770, gumboot with steel toe cap moulded pvc to protect against oil acid and alkalie re- sistance confirming to is 15298, 63mm rubber washer for female outlet of hydrant valve, supply of s.s-304 63mm single headed fire hydrant valve as per is: 5290, vtype-a, isi marked. having pvc male blank cap with chain., ceramic wool fire blanket white density: 128 kg/m3, size : 610x7100 mm; thick- ness =25 mm. weight : 3130 gsm thisckness test metod : astm d 1777& weight test metod : astm d 3776 tensile strength in kgs (1 x4 ) = 10 to 16 psi, potassium based aerosol ; first responder produces an exceptionally effective, ultra fine aerosol that provides extremely fast knockdown and rapid sup-pression of fires. aerosol mass 0.5 kg. length 142.9mm with actuator 174.6 mm.;diameter 80.98 mm.; delay time 3.5 seconds &discharge time 20 sec.operating temp. -29 c to +60 c; classification code : 1.4s potassium based aerosol ; first responder produces an exceptionally effective, ultra fine aerosol that provides extremely fast knockdown and rapid sup-pression of fires. aerosol mass 0.5 kg. length 142.9mm with actuator 174.6 mm.;diameter 80.98 mm.; delay time 3.5 seconds &discharge time 20 sec.operating temp. -29 c to +60 c; classification code : 1.4s, high velocity spray nozzles 80 , nicalchorme plated, ul listed, 3/4 bspt, high velocity spray nozzles 90 nicalchorme plated, ul listed, 3/4 bspt, high velocity spray nozzles 120 nicalchorme plated, ul listed, 3/4 bspt, hose reel with horn for co2 length : 15 mtr. hose reel made of ms having unique ball valve shut of devise with breaded hose & nozzle. drum red/ hose pipe black.drum length 15 mtr. , hose pipe length and diaas per requirement. test pressure 10 kg./cm.sq of hose pipe. control nozzle at the end is attached to control flow & direction., discharge tube with nozzle for foam 45 ltr. fire extinguisher ( 4.5 mtr. hose lenght)
 Loading, Please wait...

Connect us via What's Up