Tender For repair/replacement galvalume sheets, ceiling and certain joinery related items in permanet and temporary bldgs of n-4, narendra ground and rama devi at afs chakeri , kanpur - taking down chowkats or frames not exceeding 1.5 sqm each but with shutters (without taking off shutters from the frame), and removing from site complete all as specified and directed., ditto all as per item no.01 above but exceeding 1.5 sqm but not exceeding 4sqm each., dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed., framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to fe.290.gde-e-165, s&f solid pvc door frame of size 50mmx 47 mm made out of 5 mm plain colour pvc sheet reinforced with ms square tube all as per specification and drawing., s&f factory made solid panel factory made solid pvc moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded pvc sheet on the front face & 2mm plain colour pvc sheet on back face, supplying & fixing in frame at site as per specification & drawing, s&f pvc butt hinges medium weight, 100 mm long, complete all as specified and directed., s&f 150 mm size aluminum, anodised, barrel tower bolts of extruded section., s & f 125 mm long aluminum anodised bow handle fabricated type extruded section complete all as specified and directed., s&f 300mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate complete., factory made single extruded wpc (wood polymer composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 45 x 85 mm comprising of virgin pvc polymer of k value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying pvc solvent cement and screwed with full body threaded star headed ss screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 n (face) & 1100 n (edge), minimum comp ressive strength of 58 n/mm2, modules of elasticity 900 n/mm2 and resistance to spread of flame of class a category with property of being termite/borer proof, water/ moisture proof and fire retardant note: for wpc solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made., factory made single extruded wpc (wood polymer composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 50 x 125 mm for double shutter door comprising of virgin pvc polymer of k value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying pvc solvent cement and screwed with full body threaded star headed ss screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 n (face) & 1100 n (edge), minimum comp ressive strength of 58 n/mm2, modules of elasticity 900 n/mm2 and resistance to spread of flame of class a category with property of being termite/borer proof, water/ moisture proof and fire retardant note: for wpc solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made., factory made single extruded wpc (wood polymer composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of k value 58-60 (s
Tender For supply of refilling of water co2 type , refilling of dcp type , refilling of acb type , refilling of co2 type , refilling of foam afff type , refilling of dcp type , firefightingequipments 1 , firefightingequipments 2 , firefightingequipments 3 , firefightingequipments 4 , firefightingequipments 5 , firefightingequipments 6 , firefightingequipments 7 , firefightingequipments 8 , firefightingequipments 9 , firefightingequipments 10 , firefightingequipments 11 , firefightingequipments 12 , firefightingequipments 13
Tender For providing of custom bid for services - tender for carrying out preventive/predictive maintenance of firefightingequipments and shed equipments at lalru lpg plant
Tender For repair replacement and improvement of mcc panel starter pump moters earthing of plant em assets at stp dg lift firefighting etc at mil stn gandhinagar
Tender For annual maintenance for firefightingequipments, smoke detectors, refilling of existing fire extinguishers and other allied works at karnataka public service commission building, bengaluru.( period from(01/08/2026 to 31/07/2027)
Tender For corrigendum : jp/b862-000-mf-mr-8007/104 - chassis mounted firefightingequipment for pdh pp plant with ethane and propane handling facilities project at dahej, gujarat
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments firefighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of firefighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit firefighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all firefighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire