Tender For jp/b862-000-mf-mr-8007/104 - chassis mounted firefightingequipment for pdh pp plant with ethane and propane handling facilities project at dahej, gujarat
Tender For supply of firefightingequipments at municipal board chirawa - fire balls , co2 extinguisher (4.5 kg) , fire blankets (4x3 mtr) , fireman axe , fire gum boot , fire helmate with fibre , fire safety net , fire glaves , electric glaves , tool box with jack , fire proximity suit kit asbestos 3 layer (with radium patti) 1000° c
Tender For repair and comprehensive maintenance of swimming pool plant and equipments firefighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of firefighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit firefighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all firefighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and directed., supply
Tender For auction sale of others - scrap, cond, unserviceable pick up van (mahindra) vehicle in dilapidated condition. quantity=1 number, vehicle number ap29 v 0749 , approximately weight of vehicle=1.735 mt, total nominal weight of lot =1.735 mt location: diesel loco shed premises, moula ali secunderabad. custodian: sse dsl mly, note: chassis & engine number and number plates of vehicle should be remove and handed over to the custodian before effecting delivery. delivery by actual weighment basis only. ds-8 no.073611-25-09123 dated 20.01.2026 and state: telangana. plno.98050011 hsn code 72044100, refer to depot conditions for gstin of state railways, list of holidays and other conditions and special conditions [1] in order to make assessment the purchaser may visit the lot location and inspect the lot and satisfy themselves before bidding [2]post auction no representation shall be entertained.[3] picking & choosing of material is not allowed while taking delivery.[4] cutting is permitted and chassis & engine number of vehicle should be cut and returned to the custodian before effecting delivery. [5] purchaser has to make his own arrangements such as tools, lifting tackles, lifting equipment's such as crane, cutting equipment's and necessary trained men for cutting & loading [6] the purchaser is responsible for providing adequate safety firefightingequipment's on the location at the time of cutting and delivery. [7]. the purchaser shall be liable to make good any damage loss caused to railway property during cutting and delivery.
Tender For bid to ras bid to ras supply of supply-firefightingequipment as per technical specification tb-434-552-01,clause-8-a,annexure-boq sl no 1 to 70 for pgcil barmer-i new , spares-firefightingequipment as per technical specification tb-434-552-01,clause-8-a,annexure-boq sl no 71 and 72 for pgcil barmer-i new , etc- firefightingequipment as per technical specification tb-434-552- 01,clause-8-a,annexure-boq sl no 1 to 70 and 73 to 78 for pgcil barmer-i new , supply-firefightingequipment as per technical specification tb-434-552- 01,clause-8-b,annexure-boq sl no 1 to 35 for pgcil sirohi extn , etc-firefightingequipment as per technical specification tb-434-552-01,clause-8- b,annexure-boq sl no 1 to 41 for pgcil sirohi extn , supply-firefightingequipment as per technical specification tb-434-552-01,clause-8-c,annexure-boq sl no 1 to 7 for pgcil fatehgarh-iii extn , etc-firefightingequipment as per technical specification tb-434-552-01,clause-8-c,annexure-boq sl no 1 to 8 for pgcil fatehgarh-iii extn
Tender For bid to ras corrigendum : providing of repair and overhauling service - uninterruptible power supply (ups); l 1639 aft fire and sprinkler motor not working 415 v 3 ph 30 kw suspect defect on control panel; yes; buyer premises,repair and overhauling service - uninterruptible power supply (ups); l 1641 battery charger 24v 25a of emergency da starting batteries is not working; yes; buyer premises,repair and overhauling service - uninterruptible power supply (ups); l 1595 port qrib system not working; yes; buyer premises,repair and overhauling service - uninterruptible power supply (ups); l 1637 forward engine room ventilation system motor es 1 22kw not working in all modes; yes; buyer premises,repair and overhauling service - uninterruptible power supply (ups); l 1628 02 in nos ships galley hotplates not working in high medium range of operation; yes; buyer premises
Tender For corrigendum : supply of life saving and firefightingequipment for bangladesh dredger yard 2121 - life buoys with vessel name and home port , life buoys_vessel and home prt,lght and smk sgnl , life buoys_vessel name and home port_light , life line _l_equal to_30m, dia8mm, orange colour_ , life jackets with retro reflective matl , immersion suits_number as solas_stored , emergency breathing app.,sabre elsa-b-15 , work vests , safety harness , boat hook , stretcher , first aid kit,contain mca,english stickr , rocket parachute flares_set of 12pieces_ , emergency flashlight , line-throwing devices each _ 250m line , distress signals consist_following items , safety plan storage tube,a0size,red , fire blanket,180x120cm,fiberglass , wheeled foam extinguisher _45l_ , spare charges for foam extinguisher_45l_ , co2 extinguisher _5kg_, b, mc5 , spare charges_co2 extinguisher _5kg_,mc5 , powder extinguisher_6kg__stowage arrgt. , spare charges_powder extinguisher _6kg_ , stowage bracket_wheeled foam extinguishr , stowage bracket_co2 extinguisher _5kg_ , stowage bracket_powder extinguisher_6kg_ , portable foam applicator unit , fire locker for fireman outfit , protective suit medium,dark blue_reflctr , protective boots for fireman , protective gloves for fireman , protective helmet with visor for fireman , firemans torch,bright star 2217 ledat , firemans axe _ss with insulated handl , self-contained breathing apparatus , safety harness,protecta first ab17711uni , firemans belt with line,1.5m line , spare oxygen cylinder 6 ltr, 300 bar , valid type approval certificate , certificate_conformity and guarantee certi. , class inspection certificates , warranty extension charge for 1st year , warranty extension charge for 2nd year
Tender For supply and installation of aerosol based firefightingequipment at indoor ward, eye ward, blood bank, admin building of sdh, gunupur rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including al
Tender For supply and installation of aerosol based firefightingequipment at new chc building muniguda rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofeng