Get complete information related to latest Flap Board Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flap Board Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flap Board Tenders.
Tender For replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the energizer without
Tender For providing of customized annual maintenance contract/cmc for pre-owned products - annual maintenance contract annual maintenance contract of passenger information display system pids public address system pas software; oem ms simpleway solutions; annual maintenance contract (amc); quarterly; no
Tender For corrigendum : supply of electronic chart display information system , gps (global positioning system) with accessories , ais (automatic identification system) class b with accessories
Tender For purchase of equipment - purchase of equipment, 1. general description single stand-alone system should dispense all three types of water (type i, type ii, type iii) from a tap water feed system should be compact requiring less space. system should be supplied with 5 micron, 1 micron and activated carbon pre filter with boost pump to remove particulates in water. system should have an internal storage tank of 7 litres (or better) with complete recirculation. the system should incorporate graphic colour lcd display to provide information on system status and performance parameters such as conductivity, resistivity, temperature and storage volume and also alarm notification for troubleshooting. system should have dual wavelength uv lamp. system should have a completer recirculation facility which can able to re-circulate water through purification components to maintain high purity. the system should have a water quality sensor at the dispense point to ensure water quality. system should have volumetric dispensing options from 50 ml to 7 litres. system should have data capture using usb to keep track of water quality and software upgrades. type iii water production rate 10 litres per hour (or better).2. ultrapure (type i) water specifications resistivity: 18.2 m .cm @ 25 c dispense flow rate: up to 1.2 l/min toc: 5 ppb bacterial tvc: 0.1 cfu/ml endotoxin: 0.001 eu/ml rnases: 1 pg/ml dnases: 5 pg/ml ph: effectively neutral particulates: 0.2 m filtration3. feed water specifications water source: portable water source conductivity: 2000 s/ hardness: 350 ppm as caco free chlorine: 0.05 ppm cl chloramine: 0.02 ppm cl total chlorine: 0.05 ppm cl silica: 30 ppm sio carbon dioxide (co2): 30 ppm fouling index: 10 iron/manganese: 0.5 ppm fe/mn toc (total organic carbon): 2ppm4. warranty one + optional two years5. general terms and conditions the installation should be done at free of cost. hands-on training must be provided on operation, maintenance and troubleshooting to two-three persons at the site of installation. additional features and features in the quoted equipment which are better than those in the indent may be clearly explained.
Tender For supply of central duct cooling system , information kiosk , 3 seater chrome finish waiting chair with cushion , token display machine , crash trolley , mo bag , inverter with tubular battery , heavy duty tv stand , partition channel track with curtain