Get complete information related to latest Ftir Instrument Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ftir Instrument Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ftir Instrument Tenders.
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - rota-evaporator the rota-vapour should have a vertical condenser for standard applications with cooling surface area of 1500 cm2 or better with a protection class of ip20 or better. the rotation speed of the instrument should be 20-280 rpm or better. the water bath should have controlled temperature range of heating within a range of 0-90oc or better with a capacity to accommodate evaporating flask from 50-4000 ml with same joint. all glass components should be made of borosilicate 3.3 glass. digital interface of 4 inches or better to facilitate monitoring of temperature, speed and vaccum. there should be a provision of power cut off when actual temperature exceeds set temperature or by rapid temperature increase. the system should have timer function to regulate the time of the process and automatic aeration when pressure reaches above 1400 mbar. the entire system should have ce/csa approvals. the vaccum pump should be made up of chemically resistant ptfe diaphragm vacuum pump with a suction capacity of 1.5m3/h or better with 2(2) number of steps(heads). the final vaccum should be 7-10 mbar. the recirculating chiller should be of 3l capacity with a working temperature range of room temperature to -10oc and a cooling capacity of 500 w at 15oc., ft-irthe ftirinstrument should have transmission interface which provides classic infrared sampling for the measurement of solids, liquids or gases. the transmission module is purgeable and preferable to come with a standard cardholder. the scan range should be from 8000-350 cm-1 with a spectral resolution of 0.5cm-1 or better. the signal to noise ratio: 35000:1 or better. the system should have michelson type/ rock solid/self-compensating, dynamically aligned interferometer which removes any tilt and shear scanning error with 10 years warranty on interferometer. the system should have temperature stabilized or dtgs detector/ temperature control dlatgs detector. kbr/ znse beam splitter to meet complete spectral range. the system should be operable through a windows 10 compatible software with self-diagnostic after initialization, provision for creation of library. the software should have spectral, peak and text search function. the software should be capable of comparing spectrum, quantification and photometric data. there should be a provision of digital humidity level monitoring in internal optics through software and customized template. the system should be supplied with following accessories.hydraulic press for kbr pellet preparation software recognize diamond atr accessory with force monitoring for quick analysis of different sample) solid, liquid, paste and gels) of food, raw material, packaging material etc.installation, familiarization at installationpccorei5, 4gb ram, 1 tb hdd, 18.5 led/lcd, windows 10 , uv visible spectrometer microprocessor based wavelength range: 190 to 1100 nm with 7-8 inch led display. the system must have pre-programmed methods for water parameters which should be compatible with available reagents for the water testing. system should be true double beam uv-visible spectrophotometer with 8-cell changer the monochromator should be blazed czerny-turner type with 1200 lines/nm blazed grating. the detector should have si-diodes/ccd. system should have wavelength range from 190 to 1100 nm or better system spectral bandwidth should be 1 nm (190 to 1100 nm) wavelength setting should be 0.05 nm wavelength accuracy should be 0.3 nm wavelength repeatability should be 0.1 nm or better scan speed max 6,000 nm/min or better photometric range absorbance : -4 to 4 abs transmittance range should be : 0 % to 400 % photometric accuracy should be less than 0.005 abs at 1.0 abs light source tungsten halogen lamp & deuterium lamp photometric repeatability 0.0002 at 0.5 abs baseline stability: 0.0003 abs/h operating system (os): system should have to
Tender For e-tender for purchase of lab equipments/apparatus - lab equipments/apparatus, steel ball (3kg) 20 cm diameter, steel chain 5 meter and 1cm diameter, newton s ring apparatus, michelson interferometer, fresnel biprism, optical bench kit, radio active sources kit (brit/barc)1. gamma source kit - 4nos2. beta source kit - 4 nos, hall probes and sample, four probes and sample(temperature upto 300 c), curie temp kit, ics for electronics (2input) ic number 1 - 7408, ics for electronics (2input) ic number 2 - 7400, ics for electronics (2input) ic number 3 7402, ics for electronics (2input) ic number 4 7432, ics for electronics (2input) ic number 5 7486, ics for electronics (2input) ic numbe 6 - 7404, ics for electronics (2input) ic numbe 7 - 747266, cutting pliers and wire cutters, quinckes tube, lattice dynamics kit, dielectric constant kit, scientific tuning forks kit , frequency 256 to 512 hz, with hammer & wooden case, cro cables bnc to bnc, magnetic plotting compass, deflection magnetometer, rectangular post office box for resistance measurement, diffraction grating, glass prism, nand gates (ic 7400 (2 o/p), nor gates (ic 7402 (2 o/p), not gates (ic 7404), and gates (ic 7408), or gates (ic 7432), leds (5mm with any colour), fecl3, cathode ray tube, b.g. lamp & scale arrangement, plancks constant setup, photodiode characteristics setup, polarimeter - sugar, multi strand copper wire, with different coating colours(black,red,green,yellow), angle measurement protractor 0 to 180 degree, steel wire, 5 mm diameter, bundle 100 m, tungsten filament lamp, lamp or bulb-is:418, 60 w, incandescent bulb 100w, high pressure mercury vapour lamps (hpmv lamps), 400 watt, male dual alligator clips for oscilloscope, stefan constant kit, 400 w high pressure sodium vapour lamps (hpsv lamps), meter bridge, solar cell kit, microscope(with digital screen led screen display), herbarium press, digital microscope fluorescence laboratory microscope with pc and hd camera, electronic balance - readability 324g, accuracy-0.0001repeatability 0.0001, main body dimension 213wx356dx338h mm, pan-91mm, molecular model kit-standard - large, lightweight molecular models for classroom demonstration of organic and inorganic structures. for building models to scale of 20 cm/ and 8 cm/ . bond lengths range from 5.5 to 27 cm. atomic centers are 5 cm in diameter, finished in standard atom colors, and have a reinforced vinyl receptor at each bond position for insertion of connecting rods (bonds)., potentiometer - 4 electrodes for different titrations resolution:0.1 mvdigital led displayaccessories electrode:pt-electrodeglass electrodesilver electrode range 2v to 2vmagnetic stirrer in built, conductometer - 5 ranges0.0-20.0 s/cm ;20-200 s/cm200-2000 s/cm;2-20ms/cm20-200 ms/cmresolution 1.01 s/cmoscillator 1kh2 inbuiltcell constant 0.2-1.41accessory electrode- conductivity electrodemagnetic stirrer in-built, fume hood - velocity control of approximately 80-100 feet per minute. semi close ventilated exposures. outer construction of thick pcrc, pre coated corrosion resistant gi sheet. inner construction of high grade ss-304 provided with sliding sash made out of special grade shatter proof glass duly framed in wooden/aluminum frame with sliding motion and counter weight balanced mechanism. illumination level of approx. 800 lux on the work table. heavy duty exhaust system, comprising of dynamically balanced centrifugal impeller with high speed motor suitable frp ducting of required dimension as per the individual requirements low noise level. energy efficient., digital oil bath with magnetic stirrer - stainless steel, sensor pt, temperature 300 c, high speed rotation 3l, digital oil bath with magnetic stirrer - oil bath 230 x 130 mm 3l, uv chamber - uv viewing cabinetcabinet with removable, combination uv light source (365nm/254nm); 4-watt tubes, lightweight aluminum minicabinet, long- and shortwave irradiation for viewing tlc plates, and for uv fluorescence or absorption,
Tender For retender for supply of laboratory equipments and research equipments under idp 2023-24 - ultrasonic sonicator, abbe refractometer (digital), ice making machine/ice chillar (20kg per 24 hr), kbr pellet making machine (automatic 15 tons) , programmable high performance temperature muffle furnace 1200 degree c , magnetic stirrer , centrifuge , glass electrode for ph meter, ph meter, colorimeter , monocular self illuminating microscope magnus or equivalent, weighing balance 3 decimals wensar or equivalent, electroblotting unit brand techno or equivlent , apparatus for the study of b h curve of ferromagnetic materials, mscw - energy gap of semiconductor experimental set-up, gamma radioactive sources set nucleonix or equivalent), beta radioactive sources set (nucleonix or equivalent), mscw - power supply (transformer) for sodium vapour lamp, uv vis spectrophotometer, ph electrode, digital conductivitymeter model eq-660b ( equittronics or equivalent), digital potentiometer model eq-606( equiptronics or equivalent) , uv chamber , rotary microtome , rotary vacuum evaparatour , mscwa- colorimeter, digital tds, labomed microscope , ph meter- digital, centrifuge remi or equivalent 10000 rpm , gel electophoresis verticle, electrophoresis power pack unit, gel electophoresis horizantal, mscw -binocular microscope, homogenizer, haemoglobinometer, glucometer, centrifuge with timer, led digital microscope with battery backup, digital personal weighing balance, digital high precision weighing scale kerro or equivalent, compound microscope with 10x 45x 100x and 5x objectives, tri ply splender tadka pan 13 cm 550ml ss cookware prestige or equivalent, ss 1ltr deep frying vessle borosil, ss 1ltr cooking utensil borosil or equivlaent, paper electrophoretic unit, sahlis hemoglobinometer, neubeur blood counting chamber, hair dryer, micropipette, triple beam balance, electrophoretic unit(horizontal), microwave oven, mscw - digital colorimeter, compound microscope, centrifuge (remi r-8c), uv-visible spectrophotometer (200-1200nm), mscw - colorimeter, mscw - mini centrifuge, mscw - pressure cooker 20 litres, mscw - pressure coocker 10 litres , weighitng mechine 2 decimal digital, colorimeter wavelength range 400-700 nm labotronics or equivalent, electroporesis power pack (50-300v 200ma) tarsons or equivalent, electroblotting unit techno or equivaent, ic regulated power supply, 0-5 1a, ic regulated power supply 0-30v 1a, power supply (transformer) for sodium vapour lamp, cathode ray oscilloscope dual channel 20mhz, mscw - travelling microscope bridge type, spectrometer , quantum efficiency of photodiode study kit, verification of stefan - boltzmann law kit, meterbridge, energy gap of semiconductor experimental set-up, fermi energy of copper kit, function generators digital (upto 1mhz), digital balance upto 3 digits., refractometer , conductivity cell, calomel electrode, platinum electrode, electric oven , elctrical centrifuge machine, electric bunsen burner, digital potentiometer, digital conductometer, digital colorimeter, mscw - analog cro dual channel 20 mhz make aplab or systronics or retrack, digital dc milliammeter (with at least one decimal point reading) (atleast 100 ma), digital dc/ac voltmeter (with at least one decimal point reading), microcontroller als 8051 trainer kit, function generator (upto 1 mhz that generates sine/square/triangular wave), decade capacitance box (5 or 6 dials) (1 pf to 10 micro f), decade resistance box (5 or 6 dials) (1 ohm to 1 m ohms)