Get complete information related to latest Fuel Tanker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuel Tanker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuel Tanker Tenders.
Tender For repair /overhauling of fire-fighting service pump, water and foam tank leakage, pto gear box, main propeller shaft and electrical spare with all wheels hub greasing of vehicle no. up64 bt/2467 (fire-tender) of make ashok leyland.
Tender For repair, maintenance, and installation of plant/ systems/equipments (version 2) - npcil office cum transit accom at noida; as per scope of work; as per scope of work- operation and maintenance of various systems, equipment and fittings and supply of items at npcil office cum transit accommodation at noida - 1.1 providing supervisory services for operation & maintenance activity of office cum transit accommodation for o&m work of 11 kv/415v/240v systems, domestic water / fire water/ r.o. water/, air conditioners, water coolers, d.g sets, lighting systems, earth pits, , telephone. lines distribution systems, maintenance of lawns, flowerpots, rectification of deficiencies related to civil work like plumbing, carpentry / masonry work and office work etc. cleaning of underground water tanks, and overhead water tanks. regular check of lighting system of the building and repair and replacement of bulb, choke, holder starter and office work etc. one activity shall be considered completed by deputing one highly skilled manpower as per qualification given in tech. spec. for 9 hours in a day as per work requirement. due to sensitivity of nature of work required round the clock 1.1 highly skilled supervisor will be available round the clock for any instance and requirement as the case may be. 1.2 providing services of technician in skilled category round the clock for o & m activity at noida office cum transit accommodation for following activities :- (i) operation & maintenance of 11 kv system/equipment & transformer:- cleaning and area up keeping of 11 kv switch gear panel and transformer and replacement of silica gel in 315 kva transformer if colour changes. ht drop out fuse and condition monitoring of complete switch gear area, 315 kva transformer oil level in conservator will be checked in one month. the oil level must be maintained between 25%-75%, if it reduces it should be topped up by new tested insulating oil of hv grade per is-335. bushing are to be examined for crack and dirt deposit and are to be cleaned or replaced as necessary once in six months or earlier if required. noise/humming sound, temperature rise (over heating) and crack in bituminous compound once in a month, general cleaning of the transformer to keep it free from dust and soot s quarterly or as required. (ii) preventive maintenance of two (02) nos. 415 volts air circuit breaker, 11 kv vcb (01 nos.) and switch gear area up keeping. the contractor is also responsible for maintaining 230 volts ac distribution systems in healthy condition. the scope of work includes maintenance of db s panels, & switchgear to ensure the functioning of fan, light, distribution of electricity within noida office cum transit accommodation building. the required spares shall be provided by npcil however consumables & hard wares e.g. lubricant, petroleum jelly, tb nut bolt, lugs etc shall be provided by contractor. (iii) operation & maintenance of domestic water/fire water system: the scope of work includes operation of bore well to maintain fire water tank level. preventive maintenance of domestic and fire water system, routine testing of fire water hydrants/pumps both diesel operated and electrical pumps. dewatering and cleaning of underground fire water tank and domestic water tank six monthly. (iv) cleaning of 2 no s of overhead fire tank of 5000 liter capacity and one no. domestic water overhead tank of capacity 5000 liter and one number of solar water tank six monthly, servicing and lubrication of 2 number of domestic water pump, 3 no. sump pump. servicing and lubrication of jockey pump, main hydrant pump, fire engine pump. the required all spares parts, hardware s e.g. lubricant, petroleum jelly nut bolt, gasket etc. shall be provided by contractor. (v) operation and maintenance of solar water heating system will require weekly cleaning of solar water panel, heater replacement and maintaining temperature with heater, repair and replacement of rubber
Tender For corrigendum : repair/maint to street light junction boxes, overhead tank, pump sets and fire fighting equipments at 10 compo, csa and 427 fd hosp area at sevoke road mil stn under ge sevoke road
Tender For repair of compressor tank, battery box, lock system, telescopic cylinder, blade with electrodes filling, fire extinguisher holder, ladder and cabin, new glass fitting, bonnet cabinet, control lever and light box, diesel tank cap fabrication of mg3134
Tender For corrigendum : camc of qty twenty four machineries and ndt equipments at component repair shop - upstroke hydraulic press with hyd tank and motor pt no indimech hydraulic press sl no 7193 , extruder with machine pt no indimech extruder sl no nayg crs ewm 01 , rubber mixing machine pt no indexpell rubber mixer sl no nayg crs rmm 02 , stand for test acceptance of air system unit pt no c 3757 ue 82 sl no 01 , stand for test gen purpose hydraulic rig pt no c 3390ue 82 sl no 02 , stand for test fuel rig pt no c 3869mue 82 sl no 03 , hydraulic callibration set pt no 63b 0001na sl no 512 , pneumatic calibration set pt no 63b 0001na sl no 513 , climatic chamber minus 40 degree to 20 degree pt no climatic chember minus 40 deg sl no nayg crs cc 03 , charging unit of fire extinguisher system pt no zssp sl no 1 , sonic bond master 1000 multimode with accessories pt no 9020342 reve sl no 1000c12465079107 , ultrasonic plant pt no uzu 2 kor u sl no 169 , ultrasonic filter cleaning rig pt no uc 500w sl no 10541 , magnetic particle flaw detector pt no ferro test gwh 15 sl no 1548752 , bond testing flaw detector pt no bond master 600 sl no 60002161046 , ultrasonic flaw detector pt no epoch 650 sl no 160164102 , eddy current flaw detector pt no nortech 600 sl no 60002161072 , ultrasonic thickness meter pt no 38 dl plus sl no 161265703 , high pressure compressor pt no revell tc3 1 by 2 mk 7 compressor sl no nayg crs hpc 04 , electronic weighing machine capacity 300 kgs pt no ds 415 sl no g415028098 , oven rane 0 degree celceius to minus 300 degree celceius pt no oven 330 deg sl no nayg crs oven 05 , tu hydraulic trolley tu0014 sl no 001 , installation set for checking and pressing hp vessels pt no upos 1 sl no 28 1018107 1 , halon gas filling system pt no jj 2023 point 02 sl no lf 57
Tender For corrigendum : additional / alternation and special repair to certain building no. p-63 (sub fire station), p-47 (guest room), p-49 (e/m substation) and p-14, p-15 (static tank) at hq 31 weu