Tender For provn of dry ration stores under ge 881 ews - sch a part-i (building work):-this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., construction of block of storage shed complete all as shown on drawings and as specified., total amount of sch a part - ii (site clearance/development work), total amount of sch a part - iii (internal electric supply work), total amount of sch a part - iv (protective work), total amount of sch a part - v (area drainage work), total amount of sch a part -vi (road, path and culvert work), total amount of sch a part -vii (external electric supply work), total amount of sch a part -viii (demolition/dismantling work), sch a part - ix (misc items of work) note : this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., double walled corrugated (dwc) pipe for cable protection with outer dia 50mm and inner dia 38mm including suitable size of coupler for connection of pipe complete all as specified and directed., point wiring for one light/fan point/call bell point controlled by one way switch 5 amp with 1.5 sqmm single core multi standed copper conductor frlsh insulated and unsheathed heavy duty cable in colour code including earth wire with cable of size 1.5 sqmm copper conductor frlsh insulated, drawn into and including concealed in pvc conduit of not less than 20mm dia and 1.5mm wall thickness (isi marked) terminated into annealed steel terminal boxes including modular plate and cover for mounting modular switch/ socket switches, sockets, fan regulators etc complete all as specified and directed., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on same board., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on independent board., earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia gi light grade protection pipe, 20mm dia gi medium grade watering pipe with funnel including charcoal, dust, salt, pcc m-15 type b1 in pit with angle iron (25x25x3)mm frame work with precast rcc 1:2:4 type b-1 cover reinforced with 8mm dia tmt bars @ 150mm c/c both ways and 12mm dia ms fabricated handle, test point etc. in and including light grade gi protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate no. 3 of ssr part-i complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.note:- on testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction., inverter led light fittings batten type, 1x20w led, 230v, complete with all accessories internally per wired including lithium lon battery with charging time 8 to 10 hours and back up time up to 4 hours and connecting up with pvc insulated and sheathed, 1100 v grade, flexible, multistranded copper conductor three core cable complete all as specified and directed., led street light/ security light fitting 35 watt, 230 v, ac, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 66 protection, including provision of gi bracket made of 40mm dia, gi pipe, 1.5m long, bend to shape, complete all as specified., mcb, spn, 240 volts, 40 to 63 amps,10ka, breaking capacity, complete all as specified., mcb, spn, 240 volts, 6 to 32 amps,10ka, breaking capacity,
Tender For surface dressing of the ground/ land for plantation at r and r site at village kanwa under mkd-i oc mine of umrer sub area. (site clearance and preparatory work for mprvvn plantation work of mkd -i oc of umrer sub area).
Tender For bid to ras supply of rcc precast box , site preparation and excavation1 , site preparation and excavation2 , site preparation and excavation3 , site preparation and excavation4 , engagement of plant and machinery , rcc works , cement , sand , chips , water proofing , water and damp proofing , joining of cells1 , joining of cells2 , joining of cells3 , joining of cells4 , joining of cells5 , perforated pipes , stair case , surface of wall and painting , ventilation system , internal water supply system1 , internal water supply system2 , accessories1 , accessories2 , accessories3 , accessories4 , sewage1 , sewage2 , doors1 , doors2 , doors3 , drainage system , electrical fittings1 , electrical fittings2 , electrical fittings3 , electrical fittings4 , electrical fittings5 , flooring , fire extinguisher , furniture , air ventilation system , misc items , shed above stair case precast rcc structure box m50 grade., site preparation, clearance and hire charges for excavator with operator in green field area, cost of muck dumping from site location, cost of wbm material 350 mm thick after compaction, cost of compaction and leveling of bottom ground before rcc, hire charges for hydra with operator for placement of cells, compactor with operator, ajax mixture machine with operator., rcc works 1 2 4 250mm thick along with waterproofing compound. 50 cum,cement,sand, chips, laying of geo textile membrane of 200 gsm above rcc work, laying of waterproofing outside and inside layer and bituminous based water proofing layer outside, cost of application of epoxy resin based putty to prepare the surface for application of epoxy based adhesive, cost of application of layer of mortar above joints, cost of application of water based coating for damp proofing material both interior and exterior, cost of application of bituminous based chemical water proof on exterior side, ) /bid number : gem/2026/b/7107297 * /dated: 13-01-2026 & & / bid document 1 / 37
Tender For site clearance, earthwork,protection work(retainingwall, toewall and ccblock pitching),drainage works,granular sub-bases,bases(non-bituminous) and shoulders,bases and surfacecourses(bituminous), trafficsign,markings and other appurtenances,boxculvert
Tender For site clearance, earthwork, protection work (retaining wall and toe wall), drainage works, granular sub-bases, bases (non-bituminous) and shoulders, bases and surface courses (bituminous), traffic sign, markings and other appurtenances, box culvert.