Get complete information related to latest Fuse Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuse Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuse Panel Tenders.
Tender For providing and fitting of essential items and allied material for snow clearance operation at nathatop sanasar road - supply, testing and commissioning of 48v smps float cum boost automotive battery charger with moveable trolley stand for snow operation at nathatop - sanasar roadgeneral technical requirements for battery charger suitable for 48v vrla type battery1.) type -float & float cum boost charger for vrla type, full wave, full controlled type. 2. ) ratings- 15 a float cum boost for 48v, 150 ah vrla type battery 3. ) ac input- i) voltage 415 vac 10%ii) frequency 50hz 5% iii) phase 3 - phase 4.) d.c.output voltage settings -nominal float fc 48/54.5v (adj. by + 20%, - 5% bc 48/66.5v (adj. by + 2%, - 5%) 5.) output current limit 15a 15a 6. ) power conversion ac to dc by means of three phase full wave, half controlled bridge rectifier consisting of thyristors and diodes. 7.) voltage regulation at bridge output. + 1% of set value for + 10% input voltage variations, 0-100% load variation. 8. ripple voltage less than 3% rms without battery connected. 9. efficiency more than 80% at full load 10. protections (a) input side ac input mccb & elbs with input on/off switch and fuses, contactor (b) output side dc output mccb with output on/off switch and fuses. (c) protection current limit protection, soft start feature, surge suppressor. fast semiconductor fuses for rectifier bridge. (d) control circuit fuses (e) capacitor circuit rectifier hrc fuses. (f) over-voltage cut-back (g) charger over load / short circuit (h) blocking diode 11. controls and switches followings controls and switches are provided in the system 1 ac input source mccbs with interlocking 2 dc output mccb 3 auto/manual float/boost mode selector switch. 4 float and boost voltage variable potentiometers. 5 manual voltage adjustment potentiometer 6 test push button 7 reset push button 8 battery current adjustment potentiometers 9 heater s power supply switch 12. features the following features are provided in the systems: 10 soft start on dc side 11 class-f insulation for all magnetic 12 automatic voltage regulation. 13 automatic changeover from float to boost and vice versa based on current, drawn by battery. 14 filter circuit to eliminate ripple. 15 charger current limit 16 separate battery path current limit. 17 built-in auto phase reversal of operation. 13. meters f.c. b.c. (i)input voltmeter (i) common (ii) input ammeter (ii) input ammeter (iii) output voltmeter (iii) output voltmeter (iv) output ammeter (iv) output ammeter. battery volt meter battery ammeter earth leakage ammeter 14. indications phase on lamps (ii) output on lamp a)phase on lamps (ii) output on lamp. (iii) charger on float led (iv)charger on boost led. 15. annunciation with audiovisual alarms. (i) ac input mains failure (ii) input phase failure (iii) ac under voltage iv) input phase failure v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped xiii) charger over load xiv) earth leakage xv) dc earth fault xvi) alarm supply fuse failure xvii)battery low condition. v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped. note : all the alarms shall be provided through electronic display cards. audio alarm through buzzer, visual indication through 10 mm leds & alarm ackn. / reset and led provision is through push buttons. 16. operating ambient temperature surrounding the panel 00 to 500 c 17. surrounding the panel relative humidity. 0-95% non-condensing 18. panel (i) protective grade (ii) cooling (iii)paint ip 42 natural air-cooled smoke grey of iss-692 shade a) average winding temperature rise over ambient temperature b) insulation class c) insulation breakdown voltage. as per relevant iss. f 3 kv for 1 min withstand. 19. cables 1100 v
Tender For corrigendum : supply of spares for jyoti make 33kv circuit breaker - rectifier unit, part no. - j9574194 , spring chargingmotor, part no. - 3vc40001007 , thermal overloadrelay, part no. - 4vc680319 , lower pole assemblycomplete with all in, part no. - j71715099 , upper poleassembly complete with all in, part no. - j71715199 ,vacuum interrupter, part no. - 3vc200014 , contactmultiplication relay for 110dc, part no. - j9574187 ,ac-dc control fuse - breaker side, part no. - j9574185, breaker control switch 1 pole trip - neu, part no. -j9574183 , anti pumping relay, part no. - j479653 , h. t.connector set p.t. side, part no. - j94736722 , h. t.connector set breaker side - incom, part no. - j94736731 , closing coil assembly, part no. - 4vc49110, h. t. connector set c.t. side, part no. - j94736721 ,timer aux supply 220 v dc, part no. - j9574215 ,tripping coil assembly, part no. - 4vc590189 ,insulating stud assembly, part no. - 3vc690073 ,winding temperature relay, part no. - j479751 , master triprelay, part no. - j479744 , idmt relay for 3 o-c and 1e-fbroken cndctr, part no. - j573694 , oil temperaturerelay, part no. - j479477 , control cable connectioncomplete set , part no. - j94735371 , breaker controlswitch, part no. - j579721 , panel space heater, part no. -j479654 , thermostat setting 30-80 c, part no. - j479656
Tender For tender for supply of electrical spares - contactor as per tech specs serial no 1 , ammeter as per tech specs serial no 2, holder as per tech specs serial no 3, earth lekage relay as per tech specs serial no 4, pilot relay as per tech specs serial no 5, pilot relay as per tech specs serial no6, kit contact as per tech specs serial no 7, bolt as per tech specs serial no 8, cbt as per tech specs serial no9, kit contact as per tech specs serial no1 0, power contactor as per tech specs serial no11, thermal over load relay as per tech specs serial no12, ht hrc fuse as per tech specs serial no13, cnctr lug as per tech specs serial no14, cnctr lug as per tech specs serial no15, wrench set as per tech specs serial no16, cable asw per tech specs no 17, bolt as per tech specs serial no18, bolt as per tech specs serial no19, bolt as per tech specs serial no20, bolt as per tech specs serial no21, contactor as per tech specs serial no22, clamp grinding as per tech specs serial n.23, earth bus bar as per tech specs serial no24, tester as per tech specs serial no25, switch as per tech specs serial no26, relay cntrl as per tech specs serial no27, pliers as per tech specs serial no28, switch as per tech specs serial no29, contactor as per tech specs serial no30, isolator as per tech specs serial no31 , pilot relay as per tech specs serial no 32, power transformer as per tech specs serial no 33, auxulary contact as per tech specs serial no 34, kit contact as per tech specs serial no 35, start stop microswitch as per tech specs serial no 36, shunt trip coil assy as per tech specs serial no 37, kit contact as per tech specs serial no 38
Tender For corrigendum : supply of 11 kv 24 panel switch board - design engineering manufacturing shop testing inspection packing delivery to site of 11 kv switchboard , spare incomer breaker with trolley and 3 phase line pt mounted , spare outgoing breaker with trolley of each size and rating , numerical feeder protection and control relay of each type , numerical transformer differential protection and control relay of each type , single phase current transformer for each type and rating , single phase current transformer for differential protection for each type and rating , pt primary fuse of each rating , pt secondary fuse mcb , spring charging motor , surge arresters , tnc control switch , closing coil , tripping coil , ammeter selector switch , voltmeter selector switch , bus support insulator used in bus bar compartment of each type , bus support insulator used in cable compartment of each type , anti pumping relay , dc failure relay , master trip relay , 24 window annunciator , 10 window annunciator , hooter , led indication lamps 110v dc for each colours red yellow biue green clear white amber , led indication lamps 110v ac for each colours red yellow and biue , service test limit switches of each type and rating , limit switches used in vcb of each type and rating , electrical contact grease , installation and commissioning support as per engineering specification cd css 11kv sb es.
Tender For supply of spares for ece make ocb - cartridge fuse 2a part no bd5412 , hv fuse part no bd4104 , fixed contact assembly 400a part no bd4510 , moving contact assembly part no bd5551 , auxiliary plug assly part no bd4851 , operating mechanism complete set part no bd4911 , push trip assy part no bd4920 , shunt trip coil assy part no 1650ts , isolator spout assly part no bc9976 , earth leakage relay with digital leakage part no ea6610c , idmt rely set w 2 o c and 1 e fault set part no ea5116561 , high speed tripping relay part no ea6890 , under and over voltage relay part no ea6591 , complete wiring set for ocb ece part no bd5988 , power pack unit 110v dc part no bd5999 , instrument chamber box complete with int part no bdw7771 , epoxy resin cast current transformer r part no ba1134 , digital amper meter 200 5a part no dgm200 , voltmeter 33 kv 110 v digital part no dgv3300 , potential transformer 3point3kv 110v part no bd4102 , pt connector copper part no bd7788 , nv auxiliary switch part no bd1871 , panel jaw contact for ocb 3point3kv 400 bd40 part no bd4040 , bushbar connection r y b part no bd8818 , trolley complete with all accessories part no bd8268