Get complete information related to latest Gas Cartridge Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gas Cartridge Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gas Cartridge Tenders.
Tender For supply of 45000 - eto sterisecure cartridges ( 100% ethylene oxide gascartridge net weight 100gm (height 6 inch )compatible with eto sterilizer - b. s. surgical model - bss/2k24-001-eto ]
Tender For srphc82281210-coronary drug eluting stents (1) single wire technology on cobalt based alloy platform (2) stent with coating of biolinx polymer carrier for active drug zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.25 mm to 4 mm and length of the stent from 12mm to 38 mm. (4) the strut thickness should be 81 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) five years long term efficacy and safety of the stent in terms of target vesselrevascularisation (tvr) and in-situ thrombosis (ist) should be documented / published inpeer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For srphc82281280-des-pt/cr : coronary drug eluting stents (1) on platinum chromium platform (2) stent with coating of polymer carrier for active drug everolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter shouldbe from 2.5mm to 4mm and length of the stent from 12mm to 38 mm. (4) the strutthickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved bydcgi . the copy of dcgi approval should be enclosed in the tender bid. (9) the long termefficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For srphc82281246-coronary drug eluting stents with (1) cobalt chromium alloy and with coating of polymer carrier for active drug everolimus. (2) crossing profile less than or equal to 0.0425 inch and mid marker stent placement. (3) stent diameter should be from 2.0 mm to 4 mm and length of the stent from 8 mm to 38 mm. (4) the strut thickness should be 81 micron. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guidingcatheter (7) stent design should be open cell type. (8) stent should be approved by dcgi.the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus, everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval shouldbe enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent toa major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For srphc82281215-coronary drug eluting stents (1) with single wire design with cobalt alloy shell and platinum iridium core (2) stent with coating of biolinx polymer carrier for active drug zotarolimus shown to be effective in preventing neo-intimal hyperplasia (3) stent diameter should be from 2 mm to 5mm and length of the stent from 8 mm to 38 mm. (4) the strut should be round with thickness ranging from 81 to 91 microns (5) stent delivery system should be monorail (single operator exchange or rapidexchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) five years efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute. ]
Tender For supply of micro catheter braided two tip marker steam shapeable tip, distal tip of at least 2.1 f, , 3 d self detachable neuro embolisation coils 5to8mm 5 to 20 cm length for framing , soft tip intracranial 6f guiding catheter for distal smooth navigation like neuron penumbra , stent neuro, self expandable for intracranial aneurysm neck remodeling, , flow diversion embolisation device for intracranial aneurysm like silk vista surpass pipeline derivo , micro guide wire with hydrophilic coating floppy tip, of at least 180 cm length and 0.014 diameter , micro guide wire steel construction hydrophilic coating shapeable tip 0.008 inch diameter at least 180 cm length , micro catheter lto110 130 cm, od distal 2.4 2.7f for peripoheral intervention, glide m coating, preloaded with 0.021 , haemostatic sponge gelatin 80 mm long, 50mm broad, 10 mm thick. , semiautomatic core biopsy gun set with 02 throw lengths of 10mm and 20 mm in a single device , stent carotid self expendable , dual layered , oepn cell with outer prfe mesh such as ctoguard from inspired md , percutaneous angioseal vascular access closer system based on intra vascular collagen plug , polyvinyl alcohol particles 150to250 microns , polyvinyl alcohol particles 250to350 microns , polyvinyl alcohol particles 350to500 microns , polyvinyl alcohol particles 500to750 microns , guidewire, amplatz ultra stiff, 0.035 inch diameter, 260 cm or more length, available with 1cm, 3cm and 6 cm floppy tip segment , cobra 1 c1 visceral braided torque control catheter 5.0 french 65 cms long permitting 0.035 inch guide wire. , kampa accepss catheter 5f 65 cm length , micro catheter braided two tip marker steam shapeable tip, distal tip of at least 2.1 f, suitable for neurointervention , 3 d self detachable neuro embolisation coils 5to8mm 5 to 20 cm length for framing of ruptured aneurysm like target 360 stryker , stent neuro, self expandable for intracranial aneurysm neck remodeling, 4.5 x 20 mm such as lvis from microvention. , micro catheter lto110 130 cm, od distal 2.4 2.7f for peripoheral intervention, glide m coating, , polyvinyl alcohol particles 150 to250 microns