Get complete information related to latest Gas Cylinder Sale Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gas Cylinder Sale Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gas Cylinder Sale Tenders.
Tender For enquiry for work contract for dismantling the empty co2 cylinder and n2 cylinder after refilling and assembling of co2 and n2 cylinder at 3 x 105 mw thps sirmour
Tender For corrigendum : open tender for co2 cylinder hydrotesting at cng stations in gandhinagar%2c sabarkantha%2c aravali%2c patan and mehsana districts of gujarat
Tender For bid to ras providing of cylinder maintenance and handling service - hydraulic pressure test(hpt)and refilling of 2kg co2 extinguisher; domestic; 2 kg
Tender For supply of abc fire extinguisher 9 kg , co2 fire extinguisher 4. 5 kg , co2 fire extinguisher 2 kg , dcp fire extinguisher 25 kg bc type , co2 cartridge 200gm , dcp powder , safety helmet , hand held metal detector , dfmd , fire proximity suit , scba set with one spare cylinder , stretcher with blanket , resuscitator , electric mat , electrical hand gloves mt , safety cones , electrical siren 3 km range , safety harness belt , non-sparking tools 16 pc set , mirror trolley , wind sock with stand , eye wash , flp torch , water gel blanket , multi gas detector , fire extinguisher 75 kg wheeled , electrical hand gloves mt 650 v , wind sock , fire extinguisher 75 kg , electrical hand gloves up to 1 kv , 1 kg clean agent extinguisher
Tender For purchase of equipments - purchase of equipment:chromatographic workstation with capillary injector, packed injector, and auto-sampler should be quoted. chromatography workstation instruments should be built with self-diagnostic features and active-time management tools for better productivity, general features of chromatography workstation: column oven can accommodate two columns with maximum temperature range up to 400 c with set point resolution of 0.1 c. it should support 20 ramps & maximum temperature ramp rates of 100 c /min. cool down of oven from 400 c to 50 c in less than 5 min. fully automated with electronic pneumatic control afc / ppc / epc (digital control) for injector gas afc/epc/ppc should provide optimum performance with all types of capillary columns. system should have the capability to install a minimum of three injection and four detector ports. capable of detecting h and o across 0.01% 100% ranges (i.e., both trace in a matrix and bulk near-pure streams) column oven: operational temperature range: ambient +10 to 400 c overheat protection: programmable up to 420 c injector port: split/spitless injector 1 no packed injector 1 no, maximum temperature: 400 c, pressure setting range 0 100 psi with control setpoint of 0.01psi for specified pressure range., carrier gas flow control should have constant flow, constant pressure modes and constant linear velocity. auto injector: automatic sample injector up to 15 vials 2 ml vial with crimp set 100 nos, detector: flame ionisation detector (fid) 1 no, minimum detectable quantity: 3 pgc/s or more liner dynamic range: 1 107, maximum acquisition rate: 4 ms (250hz), thermal conductivity detector, sensitivity: >40000 mv maximum acquisition rate: 4 ms, maximum operating temp: 400 cgascylinders & fittings, gas sampling: zero air, h2, n2 and helium gascylinder with 2-stage regulators, each 1 no. four-stage gas purification panel and gas tubing. quote a suitable gas sample injector apparatus for the analysis of co2 gas, gas standards and a suitable packed column quote a 6-port gas sampling valve suitable for both manual (through syringe) and auto injection (online) quote sample line, sample loop, heated lines, filters, safety hydrogen purging, and flow control of gas. calibration gasses: suitable gas standards such as ar, he, h2, o2, co and ch4 should be providedpc and ups: pc i5 (or higher), 8gb ram, 1tb hdd, 22-inch led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. laser printer b/w, online ups sine wave capacity of 5 kva with battery power backup of 1 hour should be provided by the supplier general terms and conditions:warranty: 3 years manufacturer s warranty certificate. vendor should be an authorised provider of sophisticated high-precision chromatograph workstation systems for the past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. the installation should be done at free of cost. hands-on training for 1 day for two trainees (faculty and scholars) must be provided on operation, maintenance and troubleshooting to two to two-three persons at the site of installation. if required, hands-on training must also be given to our faculty/scholars at a later stage, without any financial commitment to university. the technical details of the quoted instrument must be available on the official website of the principal supplier. the vendor should provide the list of end-users (recent) with contact details. the vendor must submit the latest reference letters from their previous users. trained service engineers in india (with suitable certificates) for the quoted model must be readily available to resolve the technical problems. a list of recent scientific publications in reputed journals from the user institutions where the quoted mode