Get complete information related to latest Gas Mixture Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gas Mixture Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gas Mixture Tenders.
Tender For purchase of equipments - purchase of equipment:chromatographic workstation with capillary injector, packed injector, and auto-sampler should be quoted. chromatography workstation instruments should be built with self-diagnostic features and active-time management tools for better productivity, general features of chromatography workstation: column oven can accommodate two columns with maximum temperature range up to 400 c with set point resolution of 0.1 c. it should support 20 ramps & maximum temperature ramp rates of 100 c /min. cool down of oven from 400 c to 50 c in less than 5 min. fully automated with electronic pneumatic control afc / ppc / epc (digital control) for injector gas afc/epc/ppc should provide optimum performance with all types of capillary columns. system should have the capability to install a minimum of three injection and four detector ports. capable of detecting h and o across 0.01% 100% ranges (i.e., both trace in a matrix and bulk near-pure streams) column oven: operational temperature range: ambient +10 to 400 c overheat protection: programmable up to 420 c injector port: split/spitless injector 1 no packed injector 1 no, maximum temperature: 400 c, pressure setting range 0 100 psi with control setpoint of 0.01psi for specified pressure range., carrier gas flow control should have constant flow, constant pressure modes and constant linear velocity. auto injector: automatic sample injector up to 15 vials 2 ml vial with crimp set 100 nos, detector: flame ionisation detector (fid) 1 no, minimum detectable quantity: 3 pgc/s or more liner dynamic range: 1 107, maximum acquisition rate: 4 ms (250hz), thermal conductivity detector, sensitivity: >40000 mv maximum acquisition rate: 4 ms, maximum operating temp: 400 cgas cylinders & fittings, gas sampling: zero air, h2, n2 and helium gas cylinder with 2-stage regulators, each 1 no. four-stage gas purification panel and gas tubing. quote a suitable gas sample injector apparatus for the analysis of co2 gas, gas standards and a suitable packed column quote a 6-port gas sampling valve suitable for both manual (through syringe) and auto injection (online) quote sample line, sample loop, heated lines, filters, safety hydrogen purging, and flow control of gas. calibration gasses: suitable gas standards such as ar, he, h2, o2, co and ch4 should be providedpc and ups: pc i5 (or higher), 8gb ram, 1tb hdd, 22-inch led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. laser printer b/w, online ups sine wave capacity of 5 kva with battery power backup of 1 hour should be provided by the supplier general terms and conditions:warranty: 3 years manufacturer s warranty certificate. vendor should be an authorised provider of sophisticated high-precision chromatograph workstation systems for the past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. the installation should be done at free of cost. hands-on training for 1 day for two trainees (faculty and scholars) must be provided on operation, maintenance and troubleshooting to two to two-three persons at the site of installation. if required, hands-on training must also be given to our faculty/scholars at a later stage, without any financial commitment to university. the technical details of the quoted instrument must be available on the official website of the principal supplier. the vendor should provide the list of end-users (recent) with contact details. the vendor must submit the latest reference letters from their previous users. trained service engineers in india (with suitable certificates) for the quoted model must be readily available to resolve the technical problems. a list of recent scientific publications in reputed journals from the user institutions where the quoted mode
Tender For supply of h2s gas cylinder , c s cylinder methane , gas hydrogen 2.02% h2+ bal. n2 , calibration gas 2.5% methane cylinder. 5 lt , aerosol smoke detector tester
Tender For supply of spares- refrigerant gas r407c with cylinder qty: 07 kg per cylinder shaft seal cover, part no.- , ac926100076, make voltas por ac plant compressor model no. 05066-s , shss. assly with ring, part no ac926101800, make voltas for ac plant compressor model no. 05066-5 , pillow block bearing for ahu of service building ac plant , cleaning chemical (copper safe) for chiller/condenser of ac plant , pillow block bearing model-ucp 205 for ahu of switch yard control room ac package , v belt a-28 , seal cover plate , p.no:ac926100076 make: voltas for ac plant compressor model no. 05086 , shaft seal assembly , p.no:ac926101800 make: voltas for ac plant compressor model no. 05086 , charging hose 1/4" connecting (set of 3) for central ac plant , 1/4" charging nrv valve for central ac plant , liquid line filter, make voltas for ac plant compressor model no:05086 , v belt b 85 , , v belt a-30 , liquid line filter model-165 for uniflair and blue star make package ac unit and hydrogen gas dryer unit , dryer model dcl-083. code.0232500s for blue star make package ac.5.5 ton. , tyre element for fenner make f-80 tyre coupling , refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , connecting valve for refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , 3-way manifold gauge set with 3 charging hoses for r22, r134a, r407c for central ac plant , gas cylinder valve spindle key , gas cylinder adaptor for r-22 gas cylinder , gas cylinder adaptor for n2 gas cylinder , air cooled condenser model no: dohss, capacity: 8.5 tr make voltas for 132kv switch yard control room ac package , pedstal bearing size-ucp209d1 for cooling tower of contol room ac plant , brass float valve size: 20 mm (3/4??) , ratchet wrench (4-size: 1/2-inch hex, 9/16-inch hex and 1/4-inch square, 3/16-inch square) , fenner make v belt size b-98
Tender For supply of precision aneroid barometer complete with accessories model 103pm or 103 cr or equivalent , dry bulb thermometers mercury complete with accessories , wet bulb thermometers mercury complete with accessories , aneroid barometer complete with accessories , whirling psychrometer complete with accessories , mobile met kit model kestrel 5500 or equivalent , hand held anemometer complete with accessories , digital barometer reference complete with accessories , marine bucket with sea thermometer complete with accessories , empty cylinder for hydrogen gas 50kgs , technical documentation as per sotr
Tender For supply of a set of standard gasmixture for calibration of dga, 10 ltr capacity aluminum can with nozzle and screw fine control valve on to outlet valve on top of the can to obtain required gas flow with regulator consisting of :- 1) gas concentration of gases as methane 1000 ppm, ethylene 1000 ppm, ethane 1000 ppm, acetylene 1000 ppm, hydrogen 1000 ppm carbon dioxide 5000 ppm, carbon monoxide 5000 ppm and nitrogen balance - 02 nos/set. 2) methane 500 ppm, ethylene 500 ppm, ethane 500 ppm, acetylene 500 ppm, hydrogen 500 ppm carbon di oxide 500 ppm, carbon monoxide 500 ppm and nitrogen balance - 01 no/set. shelf life 12 months. canister capacity 0.5 ltr, filling pressure 20 kg/sq.cm with test certificate and suitable septa as spares.
Tender For filling up of hydrogen gas - mtps –ii-tgm & ca –hydrogen gas generation plant-filling up of hydrogen gas in the hydrogen gas cylinders and shifting to storage room and transporting of hydrogen gas filled cylinders to main tg building unit gas room from hydrogen gas plant storage room and empty hydrogen gas cylinder from main tg building unit gas room to hydrogen gas plant storage room for a period of six months (180 days) from the date of commencement of work or completion of the estimated quantity of hydrogen gas cylinders whichever is earlier and complete overhauling of high pressure reciprocating hydrogen gas compressor.