Tender For corrigendum : tender for execution of sweeping cleaning work of the various areas floors of larji power house such as main access tunnel floor, gis floor service bay floor machine hall floor generatortransformer floor turbine floor miv floor etc all th
Tender For corrigendum : enquiry for the testing of various protection relays of generator, generatortransformers and 132 kv feeders etc. installed at 3x20 mw mhps mppgcl shivpuri
Tender For bid to ras providing of custom bid for services - receipt handling storage erection testing commissioning and handing over of 1 nos of 310 mva400 kv 1 generatortransformer at mundara thermal power station gujrat
Tender For corrigendum : spares for power transformer of various ratings - relay,buchholz ,gor3,size-80nb contact rating:the contacts should make,break and carry continuesly 2amps at 250v dc or ac should make carry 10amps for 0.5secs at 250v ac or dc,for power transformers(290mva,16.5kv/235kv), valve,pressure relief ,model-t6, specifications:liquid in tank:t/foil,operating pressure:0.42,0.49,0.56,0.7kgs,operating tolerence:+or-0.07kgs, operating time:instant,valve resetting:automatic, switch resetting:manual, visualindicator resetting:manual, operating temperature:0 to100 deg.c,environment:indoor or outdoor, switch:micro switch dpdt, port opening:150pie nominal,1no,1nc, for power transformers (290mva,16.5kv/235kv), gas collecting device for buckholtz relay,290mva generatortransformer (16.5kv/235kv). gauge; type: conservator magnetic oil. for power transformers, (290mva,16.5kv/235kv)
Tender For corrigendum : design, manufacturing and replacement of hv and lv windings of 48.33mva, single phase generatortransformer of unit no. 2 r-phase-s.no.217620-02 and repair as per scope of work
Tender For supply of supply of on-line insulating oil drying system for generatortransformer of teesta low dam-iv , installation & commissioning of on-line insulating oil drying system for generatortransformer tldiv
Tender For brief scope of work covers annual maintenance of generator,and their auxiliaries including ody equipments a)removing cleaning painting and assembling back floor plates and stator cover plates & its support assembly b) inspection & cleaning of stator core assembly and rotor rim assembly, checking core tightness c) cleaning air coolers, checking the dampers etc. and auxiliaries d)checking and cleaning ody equipments like generatortransformer,cts etc. commissioning of the unit after completion of works.
Tender For work of arresting oil leakage from various locations of station transformer, generatortransformer, ict & unit auxiliary transformer through on-line leak proof system on as & when required basis.
Tender For purchase of various material to repair failed distribution transformers at in-house transformer repairing center(trc) at dabhan under nadiad circle office.
Tender For corrigendum : purchase of pipes, bends and flanges for generatortransformer cooling pipeline for mahi ph-i, banswara and mahi ph-ii, bagidora.