Get complete information related to latest Gi Pipe Bracket Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gi Pipe Bracket Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gi Pipe Bracket Tenders.
Tender For supply of civil materials for day to day maintenance under postal civil enquiry, meghdoot bhawan, new delhi. - putty for glass pans , m seal (60 gm packet) , 3mm thick transucent white acrylic plastic , cpvc solvent 200 ml per pack , ptmt-waste coupling 38/40 mm , 15 mm ptmt bib cock with flange (fancy) make of prayag of equilent. , ptmt ball cock 15mm complete with epoxy coated aluminium rod & h.d. ball , anodised aluminium hanging type door stopper. , ply wood 5 ply with commercial ply on both faces 6mm thick. , ptmt angle stop cock with flange 15mm. , u-pvc pipes (working pressure 4 kg/cm2) single socketed pipe 110mm dia. , upvc bend 87.5 75mm bend 110mm. , upvc socket 110mm. , oxidised mild steel screws 30 mm. , polyethylene water storage tank with cover and suitable locking arrangement , stainless steel kitchen sink without drain board 610x460 mm bowl depth 200 mm. , rectangular shape 5 mm thick mirror of size 600x450 mm with plastic moulded frame. , 15 mm nominal bore and 600 cm length pvc connection pipe with nozzle make of prayag or equilent. , c.p. brass bib cock 15 mm , c.p. brass long body bibcock 15 mm , c.p. brass angle valve 15 mm , flushing cistern p.v.c. 10 litre capacity (low level) (white) (with fittings, accessories and flush pipe) , 15 mm ptmt bib cock , 15 mm dia ptmt stop cock (male thread) , ptmt pillar cock , ptmt-waste coupling 31/32 mm , nails without head , u-pvc pipes (working pressure 4 kg/cm2) single socketed pipe 50 mm dia. , upvc bend 87.5 75 mm bend 50 mm. , upvc socket 50 mm. , upvc tee 50x50x50 mm. , upvc 50 mm dia pipe clamp. , ptmt 20 mm dia tank nipple., towel rack (size: 24x10x5 inches) is made of stainless steel material. wall mount with swivel towel bar and (4x28) towel hook and with 3 no. rod of approved quilty etc. , stainless steel towel ring of approved quilty etc. , stainless steel towel rod of approved quilty etc. , aluminium sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per 15: 1868) 250x16 mm. , chlorinated polyvinyl chloride (cpvc) pipe 20 mm nominal dia , godrej mortice lock (6 lever decore brass handle code unspsc 461715985000423). , ptmt floor grating , 4 mm glass pane sheet , magnetic catcher double strip horizontal type , stainless steel wire guage (grade-304) aperture 1.4 mm and 0.50mm dia wire
Tender For supply of nq core lifter , nq core lifter case with ring , t-6 bearing , t-8 bearing , nq overshot latches with spring , water swivel packing -81 mm , wash pipe 81 mm , nq barrel head with guide coupling , nq shut of valve
Tender For corrigendum : 21/2024-25 purchase of laqshya instrument - purchase of instrument ( laqshya), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, fetoscope - technical specification of infant fetoscope should be 135 75mm weight should be up to 350gm should be 40cm h20 presser limiting valve inspiratory resistance should be 5cmh2o (at 50l/min), delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on
Tender For supply of hydraulic hose pipe and end fittings - double wire braided high pressure hydraulic hose size 3 by 8 inch , double wire braided high pressure hydraulic hose size 1 by 4 inch , double wire braided high pressure hydraulic hose size 1 by 2 inch , double wire braided high pressure hydraulic hose size 3 by 4 inch , flexible rbr hose pipe with synth water hose pipe bore size 1 by 2 inch , bsp female swivel end fitting size 3 by 8 inch , bsp female swivel end fitting size 1 by 4 inch , bsp female swivel end fitting size 1 by 2 inch , bsp female swivel end fitting size 3 by 4 inch
Tender For corrigendum : supply of spare parts n services required to ensure aner catiiib h6013 deployed at cpu thondi operation - both side engines swivel brackets need to be checked if require the same to be repaired or replaced , both gear boxes overhauling to be carried out , engine gasket kit need to replaced and water line need to cleaned , fly wheel damaged need to be repaired or replaced , starter motor servicing nee to carried out
Tender For corrigendum : supply of spare parts n services required to ensure purna catiii bh 6014 deployed at cpu mandapam operation - controle cables need to be replaced , batteries are not holding charge and same need to be replaced , battery are not holding charge due to the battery cables need to be check if require the same to be rectified or replaced , battery switch is not working to be repaired or replaced , fuel hoses from main tanks to ru tank need to be check if require the same to be rectified or replaced , water separator are not working to be repaired or replaced , prime bulb is not working to be replaced , navigation lights need to be checked , if require the same to be repaired or replaced , cabin light need to be checked , if require the same to be repaired or replaced , bilge pump is not working to be repaired or replaced , toggle switch is not working to be rectified or replaced , electric wires are damaged and need to be replaced , battery leg and terminals are damaged and need to be replaced , controle box set is not working to be repaired or replaced , antifouling paint work need be carried out to enhance a vessels performance and durability , both engines overhauling to be carried out , both gear boxes overhauling to be carried out , both side engines swivel brackets need to be checked , if require the same to be repaired or replaced , fuel tanks need to be cleaned