Web Analytics Made Easy - StatCounter

Hbc Fuse Tenders

Get complete information related to latest Hbc Fuse Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hbc Fuse Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hbc Fuse Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39179914 Due date: 11 Feb, 202511 Feb, 2025 10.00 Lacs
Tender For repair / maint of apfc panel, acb panel, lt panel and connected works at mil stn kanasar

CTN :39221995 Due date: 17 Feb, 202517 Feb, 2025 19.96 Lacs
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - coal mines; electrical system or installation, providing and fixing testing lt control panel consisting 1 nos 1600 amp 01 800 amp acb at lalmatia substation of rajmahal..

Central Government/Public Sector

CTN :39196032 Due date: 13 Feb, 202513 Feb, 2025 NA
Tender For tender for supply of fuses din ns t type as per specification - 125 amp hrc/hbc fuse din type size 00 as per specification , 16 amp ns type fuse link as per specification , 80 amp din type fuse link size 00 as per specification , 63 amp t type fuselink as per specification , 100 amp fuse t type as per specification

Central Government/Public Sector

CTN :39199884 Due date: 22 Feb, 202522 Feb, 2025 30.17 Lacs
Tender For cwe/kas-104/2024-25 repair/ maint of ht electric installation and distributions tranformers, rmu, acb panels, joints and other connected items at subathu mil station under ge kasauli

CTN :39148871 Due date: 06 Feb, 202506 Feb, 2025 14.49 Lacs
Tender For repair of ht/lt acb panel along with other allied works for smooth running of public health services under maintenance booth sector 12, l-39, chandigarh (ch. to 2215 non plan)

State Government

CTN :39156161 Due date: 07 Feb, 202507 Feb, 2025 1.34 Lacs
Tender For supply of electrical items as per annexure-d at sonari lignite project, rsmml, ceu lignite office, barmer - providing & fixing of 240/415 v residual current circuit breaker (rccb) conforming to (is:12640-1)/ iec 61008 -1 , rated 4 kv impulse withstand voltage truly current operated and shall operate on cbct mechanism, provision for pad lock, min. operation 10,000 up to 63 a rating and 5000 for 100 a rating and minimum phase termination capacity of 35 sq.mm. rigid wire, ip 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. rccb 63 amp, 4 pole rccb 100 amp, 4 pole, providing & fixing of iso certified company made tp&n, 415 v ac-23a front handle operated switch disconnector fuse unit, cubical type, without metallic enclosure (for panel mounting), as per pwd specification for electrical works conforming to is/iec 60947-3 : 1999 in existing panel with hbc fuses including making connections with lugs, testing etc as required sfu (switch fuse unit), 63 amp, 3 pole with handle, providing & fixing of 240/415 v ac mcb with positive isolation of 10ka breaking capacity (8/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, lsi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947- 2, low watt losses, trip free mechanism, energy limiting of class 3 as per iec, minimum phase termination capacity of 35 sq.mm. conductor line load reversibility, ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 up to 20 a rating and 10,000 up to 63 a, 5000 for 80 a & above rating including making connections, testing etc. as required. single pole mcb 6a to 32 amp double pole mcb 6a to 32 amp, lightening arrester, sis heavy duty 9 kv, 10 ka, pipe earthing as per is:3043- 1987 with 3.0 mtr. long, 40 mm dia. ' b ' class g.!. pipe is: 1239 (part-1) 2004, equivalent to bs : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof polypropylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal. all as per pre approved by engineer in charge., providing and fixing 180 cm high fencing with angle iron post size 50x50x6mm placed at every 3 meters apart and 45cm in ground embedded in cement concrete 1:3:6 (30x30x60cm) corner and every 10th.post to the strutted with sox50x6 mm angle iron provided with 6 horizontal lines and 2diagonals of g.l. barbed wire between two post fitted and fixed with g.i. staples including each works in excavation etc. complete., supply & laying following size earth strip in horizontal or vertical run in surface by means of earth strip dmc insulator including riveting/ soldering/ welding, jointing shall be done by overlapping and with 2 set of brass (for cu strip) / gi (for gi strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. all as per pre approved by engineer in charge. 25x3 mm copper strip 30mm x 6mm alum. strip, providing & fixing of iso certified company made lightning conductor finial as per pwd specification for electrical works as per is 2309-1989 made out of 25 mm dia.,300 mm long copper solid rod having single prong at top with 85 mm dia., 3 mm thick copper base plate including holes etc. complete as required. all as per pre approved by engineer in charge.

State Government

CTN :39156162 Due date: 07 Feb, 202507 Feb, 2025 1.15 Lacs
Tender For supply of electric items as per annexure-d at giral lignite project, rsmml, ceu lignite office, barmer. - p & fixing powder coated crca sheet enclosures on existing angle iron frame by means of nuts and bolts and making holes, din rail etc. as required 2.5 mm thick., providing & fixing of 240/415 v residual current circuit breaker (rccb) conforming to (ls:12640-1)/ iec 61008 -1 , rated 4 kv impulse withstand voltage truly current operated and shall operate on cbct mechanism, provision for pad lock min. operation 10,000 up to 63 a rating and 5000 for 100 a rating and minimum phase termination capacity of 35 sq.mm. rigid wire, ip 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. rccb 63 amp, 4 pole, providing & fixing of iso certified company made tp&n, 415 v ac-23a front handle operated switch disconnector fuse unit, cubical type, without metallic enclosure (for panel mounting), as per pwd specification for electrical works conforming to is/iec 60947-3 : 1999 in existing panel with hbc fuses including making connections with lugs, testing etc as required sfu (switch fuse unit), 63 amp, 3 pole with handle, providing & fixing of 240/415 v ac mcb with positive isolation of 10ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, lsi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947- 2, low watt losses, trip free mechanism, energy limiting of class 3 as per iec, minimum phase termination capacity of 35 sq.mm. ,conductor line load reversibility, ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 up to 20 a rating and 10,000 up to 63 a, 5000 for 80 a & above rating including making, connections, testin~ etc. as re_quired., single pole mcb 6a to 32 amp, double pole mcb 6a to 32 amp pipe earthing as per is:3043- 1987 with 3.0 mtr. long, 40 mm dia . ' b ' class g.!. pipe is: 1239 (part-1) 2004, equivalent to bs : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof polypropylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal. all as per pre approved by engineer in charge., providing and fixing 180 cm high fencing with angle iron post size 50x50x6mm placed at every 3 meters apart and 45cm in ground embedded in cement concrete 1:3:6 (30x30x60cm) corner and every 10th.post to the strutted with 50x50x6 mm angle iron provided with 6 horizontal lines and 2diagonals of g.!. barbed wire between two post fitted and fixed with g.!. staples including each works in excavation etc. complete., supply & laying following size earth strip in horizontal or vertical run in surface by means of earth strip dmc insulator including riveting/ soldering/ welding, jointing shall be done by overlapping and with 2 set of brass (for cu strip) / gi (for gi strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. all as per pre approved by engineer in charge. 25x3 mm copper strip 30mm x 6mm alum. strip, providing & fixing of iso certified company made lightning conductor finial as per pwd specification for electrical works as per is 2309-1989 made out of 25 mm dia.,300 mm long copper solid rod having single prong at top with 85 mm dia ., 3 mm thick copper base plate including holes etc. complete as required. all as per pre approved by engineer in charge. providing & fixing of recessed/surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is-8623-1 & 3 / iec 61439- 1 & 3. powder painted complete with din rail making i

CTN :39168388 Due date: 10 Feb, 202510 Feb, 2025 NA
Tender For supply of 6 amp. hbc fuse link with off set tag (2 hole fixing bolted), as per gec list no. tsa-6, conforming to is: 13703-(part 2/ sec.2) of 1993 or latest.

Central Government/Public Sector

CTN :38801490 Due date: 07 Feb, 202507 Feb, 2025 15.36 Lacs
Tender For corrigendum : providing of custom bid for services - overhauling including repair and complete servicing of 250 to 500 kva 11kv433v oil immersed outdoor type power distribution tap changing transformer qty13nosand 16 nos air circuit breakers acb at various substations in sai n..

State Government

CTN :39111716 Due date: 06 Feb, 202506 Feb, 2025 NA
Tender For dagwadi upsa irrigation scheme deulgaon raja distt. electrical maintenance and repair works of electrical system (acb, mccb panel board bus bar chamber switch fuse sdf terminal spreader etc) at buldhana
 Loading, Please wait...

Connect us via What's Up