Get complete information related to latest Heater Blower Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Heater Blower Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Heater Blower Scrap Tenders.
Tender For supply and installation of medium fish feed mill machineries in hojai district under ridf xxvi - bucket elevator with accessoriesms body (min 5 m ht) powered by 1 hp motor connected to a tank hoper (no 1) (size 1250*1250*1600 mm thickness 2 mm) above with iron stagging (min 3.50 m ht) for storage of raw materials upto 300 kg capacity., pulverizer machine/ crusher/ grinder machine with accessoriespulverizer machine/crusher machine (no 1) ms body powered by 15 hp motor with 200-250 kg per hour crushing capacity with cyclone provision., siever machine with accessoriessiever machine: siever machine/vibro separator run by 3hp with screw conveyor (no 1) run by 1 hp motor carrying finely sieved powder to mixture machine inlet and another screw conveyor (no 2) run by 1 hp motor carrying coarse powder turn to fine powder by a finer pulverizer machine (no 2) run by 15 hp motor to mixture machine inlet., bucket elevator with accessoriesbucket elevator (no 2) for mixture machine made of ms body (min 5.40 mt ht) powered by 2hp motor lifting pulverizer material to mixture machine via a hoper., tank/hoper for mixture with accessoriestank/hoper for mixture (tank no 2) made of 2mm thick plate of size 1250*1250*1500 mm fixed above an iron stagging (min 3.3 m ht) for feeding into mixture machine., feed mixture(horizontal/vertical) machine with accessoriesfeed mixture (horizontal/vertical) machine attached with reducing gear box mixer machine powered by 2 hp motor of min size 1200*600*800 mm., elevator for extruder machine with accessorieselevator for extruder machine: bucket elevator (no3) made of ms body (min 6 m ht) powered by 2 hp motor lifting mixed material to a tank for feeding into extruder machine., tank/hoper with accessories for feeding extruder pellete machinetank/ hopper for extruder : (no-3) made of 2mm thick plate of size 1250 x 1250 x 1500 fixed above an iron staging ( min 3.3m ht.) for feeding into mixture machine., extruder pellete machine with accessories to produce floating pelletsextrude pellet machine: powered by 45 hp motor with twin screw for producing floating pellets with 200kg per hour production capacity., steam boiler with accessoriesboiler of appropriate capacity with necessary blower pipe line for boiler ( internal/ external), air conveyor (no.1) made of ms body ( min 6 m ht.) run by 3hp motor for sending pellet to counter flow cooler fan ( cooler cum dryer) run by 5 hp motor over a iron staging of min 2.5m ht, then to 4 layer grader cooler ( size 1.5 x 1 x 1 m) run by 1hp motor for drying & cooling towards the inlet of air conveyor (no. 2) in flavoring section, blower pipe line for boiler(external) with accessoriesboiler of appropriate capacity with necessary blower pipe line for boiler ( internal/ external), air conveyor (no.1) made of ms body ( min 6 m ht.) run by 3hp motor for sending pellet to counter flow cooler fan ( cooler cum dryer) run by 5 hp motor over a iron staging of min 2.5m ht, then to 4 layer grader cooler ( size 1.5 x 1 x 1 m) run by 1hp motor for drying & cooling towards the inlet of air conveyor (no. 2) in flavoring section, coller cum dryer with accessoriesboiler of appropriate capacity with necessary blower pipe line for boiler ( internal/ external), air conveyor (no.1) made of ms body ( min 6 m ht.) run by 3hp motor for sending pellet to counter flow cooler fan ( cooler cum dryer) run by 5 hp motor over a iron staging of min 2.5m ht, then to 4 layer grader cooler ( size 1.5 x 1 x 1 m) run by 1hp motor for drying & cooling towards the inlet of air conveyor (no. 2) in flavoring section, blower pipe line(internal) with accessoriesboiler of appropriate capacity with necessary blower pipe line for boiler ( internal/ external), air conveyor (no.1) made of ms body ( min 6 m ht.) run by 3hp motor for sending pellet to counter flow cooler fan ( cooler cum dryer) run by 5 hp motor over a iron staging of min 2.5m ht, then to 4 layer grader cooler ( size 1.5 x 1 x 1 m) run by 1hp motor for dr
Tender For supply of self starter motor assy 12v , engine head gasket , sleeve piston ring assy , blower fav for cooling , valve set , carburator assy , fan belt
Tender For corrigendum : replacement of em items against ber held with ge i rnd east bangalore - supply, installation, testing & commissioning of double skin horizontal air handling unit of fully capacity, complete with double skin insulated with cfc free foam (puf) panels of 25mm thick, 42 kg/cum density. sandwitched between 0.6 mm thick g.i. sheets. outer skin shall be pre coated g.i. sheet pre coated off white. ahu frame works shall be of pre cast vertical and horizontal extruded aluminium profile with three way corner frame sections. frame construction should bear the load of structure and load of the frame structure shall be uniformly distributed along the entire housing of the ahu. food grade self adhesive coated neoprene gasket to be provided between panels and structure of the ahu to ensure the entire housing is airtight., backward curved blower to be supplied along with motor (kruger/nicotra). filter will be of 10 mic as pre filter, 3 mic as fine filter. cfm as below with 60-80mm sp complete all as specified and directed., note: rate quoted to be deemed to include civil works for hvac like breaking and opening for entry and exit of supply ducts from ahu room, exhaust ducts into shafts for exiting copper pipes / drain pipes also. fire rated material of 25mm thick phenotherm to be used near civil closures for fire resistant properties., a) 13200 cfm, 60mm static ahu capacity 33 tr., 11 tr dx outdoor ac unit complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a minimum capacity.note: rate quoted to be deemed to erection of condenser unit platform (ms angle frame with 02 coats of red-oxide and 01 coat of enamel black paint) with ms works for duct support., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 22 tr ducted packaged ac unit with 8800cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 11 tr ducted packaged ac unit with 4400cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 8.5 tr ducted packaged ac unit with 3500cfm complete all as specified and directed., supply, installation, testing & commissioning of air cooled ducted split air conditioners of capacity 8.5 tr with r2 series: r 407c eco friendly refrigerant, nominal cooling capacity 1,02,000 btu/hr, nominal air flow 3400 cfm, microprocessor based with lcd display controller and hermetically sealed scroll type compressor, all necessary connections with suitable size of copper cables and initial gas charging, provision of necessary pcc platform / iron angle frame for outdoor unit complete all as specified and directed by engineer-in-charge., dismantling / taking down / transporting carefully old acs outdoor & indoor unit with all connected acessories and to be deposited in mes store complete all as specified and directed., dismantling / taking down / transporting carefully old unserviceable ducting items off any size and capacity with all connected accessories and to
Tender For supply of set of items for 30kw oil cooling blower motor for cgl make suitable for 6412 c3 single row deep groove ball bearing. a set consist of 05 items in 05 nos. set details are as annexure -a and as per drawing attached of 3 phase locomotive.
Tender For rubber gasket having length 3.5 mtrs each nos. for oil cooling blower (ocb) dome as per ref.10 of clw drg.no. clw/es/3/sk-6/0023 alt-j. test certificate to be provided with supply.
Tender For supply of oil cooling blower motor of continuous rating 30 kw (centrifugal design) for three phase locomotive as per rdso's spec. no. e-10/3/09 (motor) amendment no.01 to 06 as per rdso's letter no.el/3.2.176/1 dt.22.12.2021.