Get complete information related to latest Hex Nipple Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hex Nipple Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hex Nipple Tenders.
Tender For replacement of u.g cable, terminal box and related accessories for median led tubular pole located at b.h road and hassan road coming under arsikere cmc limits
Tender For supply of g.i. hexnipple 40 mm., is:1879 (material used in icf coaches for water pipeline connection) [ warranty period: 30 months after the date of delivery ]
Tender For supply of taking down of light fittings of any type size and model complete all as specified , taking down of brackets of any type size and model complete all as specified , m and l in repair steel tubular swaged poles complete with cast iron base plate finial taper plug , m and l in repair steel tubular swaged poles complete with cast iron base plate, finial taper plug , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , s and f in repair led street light fitting 120 watt 230 v ac outdoor type with high pressure die cast aluminum hosing , supply and fixing in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics and equipped , s and f in repair led flood light 150 watt 230 v ac outdoor type with thermal management in multiple optics and equipped , s and f cable junction box 155x210x92 mm in size, made out of thermoplastic having ip 66 protection for outdoor installation fixed with 4 way , supply and passing through steel tubler pole service connection 1100 volts grade multicore fr round insulated copper conductor , s and f single arm bracket made of 40mm dia 1.0mtr long for security light with mounting ms clamp , s and f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all , m and l for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , taking down out unservicable or servicable ug cable of any cross section area and connection etc. , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth , returning filling in including spreading, levelling watering and well ramming in layers not exc. , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. , m and l sand cushioning dry in trenches for protection of ug cables below above and around the ug cable , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable , s and l for cable in trenches or passing through pipe, xlpe insulated 25 sqmm 4 core. , s and l for cable in trenches or passing through pipe, xlpe insulated, heavy duty, galvanised steel strip or wire armoured electric lt cable 10 sqmm 4 core. , re laying fixing or passing through xlpe insulated armored electric power ug cable etc. , s and f 40 mm high density polyethylene pipe hdpe of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. complete all as specified and directed . , s and f galvanised iron pipe 40mm bore dia light grade for protection of ug cable laid in floors , labour only for horizontal boring for passing protection pipe up to 80mm bore dia under road foot path, not exc. 10.00 mtr , m and l for pcc 1.2.4 type b1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces , m and l for pcc 1.3.6 type c2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed. , s and f hdpe dwc double walled corrugated of diameter 25 mm including disconnection and connection of cable. , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn , wrecking crow bar or claw bar as per is 706 (q3)
Tender For supply of taking down of light fittings of any type size and model complete all as specified , taking down of brackets of any type size and model complete all as specified , m and l in repair steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts and screws as specified , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , s and f in repair led street light fitting 120 watt 230 v ac outdoor type with high pressure die cast aluminum hosing. , s and f in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics and equipped , s and f in repair led flood light 150 watt 230 v ac outdoor type with thermal management in multiple optics and equipped with ip66 protection , s and f cable junction box 155x210x92 mm in size made out of thermoplasti having ip 66 protection for outdoor installation fixed with 4 way bakelite cable terminals , supply and passing through steel tubler pole service connection 1100 volts grade multicore fr round insulated copper conductor , s and f single arm bracket made of 40mm dia 1.0mtr long for security light with mounting ms clamp , s and f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all tees bends elbows , m and l for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , taking down out unserviceable or serviceable ug cables of any cross sectional area and connections including bricks , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth taking out and laying of cables etc. , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above , m and l sand cushioning dry in trenches for protection of ug cables , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable , s and l for cable in trenches or passing through pipe xlpe insulated wire armoured electric lt cable 25 sqmm 4 core. , s and l for cable in trenches or passing through pipe xlpe insulated heavy duty galvanised steel strip or wire armoured electric lt cable a 10 sqmm 4 core. , relaying fixing or passing through pipe xlpe insulated armoured electric power ug cable heavy duty , s and f 40 mm high density polyethylene pipe hdpe of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. , s and f galvanised iron pipe 40mm bore dia light grade for protection of ug cable laid in floors , labour only for horizontal boring for passing protection pipe up to 80mm bore dia , m and l for pcc 1.2.4 type b1 using 20 mm graded aggregate as in coping for pole including form work and finishing , m and l for pcc 1.3.6 type c2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed. , s and f hdpe dwc double walled corrugated of diameter 25 mm including disconnection and connection of cable , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground , wrecking crow bar or claw bar as per is 706 (q3)
Tender For supply of taking down of light fittings of any type size and model complete all as specified. , taking down of brackets of any type size and model complete all as specified and directed. , m and l in repair steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts , m and l in repair steel tubular swaged poles complete with cast iron base plate , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , supply and fixing in repair led street light fitting 120 watt 230 v ac outdoor type , supply and fixing in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics , supply and fixing in repair led flood light 150 watt 230 v ac outdoor type with thermal management , s and f cable junction box 155x210x92 mm in size made out of thermoplastic aving ip 66 protection , supply and passing through steel tubler pole service connection 1100 volts grade multicore fr round insulated copper conductor , s and f single arm bracket made of 40mm dia 1.0mtr long for security light with mounting ms clamp , s and f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes junction terminal , m and l for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs , taking down out unserviceable or serviceable ug cables of any cross sectional area and connections including bricks gi pipe etc. , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth taking out and laying of cables etc. , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm in soft loose soil complete all as specified , removing excavated materials soils not exc. 50.00 mtr , m and l sand cushioning dry in trenches for protec tion of ug cables , m and l for fly ash bricks locally available laid dry width wise across the line of cable , supply and laying for cable in trenches or passing through pipe xlpe insulated heavy duty , supply and laying for cable in trenches or passing through pipe xlpe insulated 10 sqmm 4 core. , re laying fixing or passing through pipe xlpe insulated armoured electric power ug cable 10 sqmm 2 core to 25 sqmm 4 core , s and f 40 mm high density polyethylene pipe hdpe of pressure rating 6 kgf cm2 fixed complete to walls , s and f galvanised iron pipe 40mm bore dia light grade for protection of ug cable laid in floors , labour only for horizontal boring for passing protection pipe up to 80mm bore , m and l for pcc 1.2.4 type b1 using 20 mm graded aggregate , m and l for pcc 1.3.6 type c2 using 40 mm graded aggregate as in foundation for pole etc complete , s and f hdpe dwc double walled corrugated of diameter 25 mm including , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground , crimping tools (q3)
Tender For supply of m.s reducer hexnipple 55mm bsp thread for 3-phase memu, as per attached drg. no. mem u/cnb/g/2025/02. [ warranty period: 12 months after the date of delivery ]
Tender For supply of m.s reducer hexnipple 41 mm bsp thread for 3-phase memu, as per attached drg. no.- me mu/cnb/g/2025/01. [ warranty period: 12 months after the date of delivery ]