Tender For bid to ras corrigendum : providing of custom bid for services - manning, operation, maintenance and technical management of (pwyhs) inclusive of automatic smoke detection and fire alarm and (hvwss) for transformers installed at muss for providing electric power supply to fourth containe..,custom bid for services - manning, operation, maintenance and technical management of (pwyhs) inclusive of automatic smoke detection and fire alarm (hvwss) for transformers sub- station for installed at two different locations providing power supply ..
Tender For corrigendum : supply of hydraulic power pack unit 2 hp 20 liters oil tank capacity (without oil) flow 1.0 l/min@ max. pressure 700 bar, consisting of single stage radial piston pump with bell housing directly driven by 2 hp/single phase, 230v/50 hz. electric motor, hydraulic elements- hand lever operated directional control valve, pressure relief valve, 100 dia. pressure gauge, all mounted on top of the oil tank. tank accessories - filter breather, suction strainer, oil level indicator etc. hydraulic elements will be indigenous reputed make :- polyhydron/ prism and hydroline make, model:-mpu-2m-20-hs
Tender For supply of hydraulic power pack unit 2 hp 20 liters oil tank capacity (without oil) flow 1.0 l/min@ max. pressure 700 bar, consisting of single stage radial piston pump with bell housing directly driven by 2 hp/single phase, 230v/50 hz. electric motor, hydraulic elements- hand lever operated directional control valve, pressure relief valve, 100 dia. pressure gauge, all mounted on top of the oil tank. tank accessories - filter breather, suction strainer, oil level indicator etc. hydraulic elements will be indigenous reputed make :- polyhydron/ prism and hydroline make, model:-mpu-2m-20-hs
Tender For supply of cab ac compressor circuit breaker for hvac /rs-9. model: gv2me14 make-schneider , top insulator & mechanism assy-vcb. part no: 5520000 make: schneider electric. , power cb/cab hvac current rating-10a voltage rating-415v operating temp-25 to 75 c mcb 3 pole model
Tender For sale of incubator (memmert type) model: pew-60m (b) s. s. , axioscope h microscope with photoghrapetic accessories , horizontal laminar flow clean air workstation with s.s. table, uv light model 1500c-48-24-24 , electroquip' autoclave vertical laboratory: - size 35 x 55 cm complete unit model s.s. eq 141 , lab hot air oven, size 24" x 24" x 24" with air circulation and digital temperature controller , electric loop sterilizer , sartorius make semi micro balance, model: bp 210 d , pcr thermal cycler, model: ptc-1152 , vortex mixture vx 100, 200-300 rpm , heat sealer no. 5390000024 230w/50 hz film no. 0030127650 , -white light trans illuminator 25 x 25cm, code 107172 , ph meter, ph test 10 water prof, ph tester, 10 tester , microcentrifuge (m.c.i.) cat no. 107110 of bangalore genei , remi make magnitic stirrer with hot plate model 1 mlh , remi make research centrifuge pr-24, microprocessor-controlled centrifuge with standard accessories , spinwin micro centrifuge-tarson 6 x 1.5 , spiner mini micro centrifuge , ups 500 va (hi-safe) , protek make line interactive offline ups 2.5 kva input dc 24, vdc with 45-50 minimum backup , power ware ups 6 kva , elite power supply 300-230 v, output range 10-30, 4-400 ma, code no. 1001004 , suvik make automatic servo stabilizer 75 kva , refrigerator (godrej)-165 liter model: 165l gc , samsung ref 230 ltr, rt-23 fvd bi/xtl, (freedge) , mini magic super water cooler voltas make sr. no. , 6210009m08 +114770 , l. g. make double door refrigerator, model 325 tm , blue star storage water cooler, model sdlx15 stainless steel 15 ltr. cooling & 15 ltr. storage , l. g. refrigerator 280 ltr., model ref 298 lng4 super ino , lg silver ultima 305 vvs refrigerator ff 290 liter , 30 gdp airbat five-star r. o. system , lg refrigerator 360 ltr. model d-402rshm (sv) , amtrex shizuka window a.c. 2.0-ton, item code-a1bj10cs , lg air conditioner lsa11851 rae1 (split a.c) , l.g. ac split 2.0 tons lsa 2481 , l.g. make split a.c. 2.0-ton b24xwasi-83 dvi , l.g. make split a.c. 1.5-ton 18xwas-1-ae , lg multi split a.c. 2 ton, lna-24 twasia , lg make split a.c. 2.0 ton, model - 6vb1vf1 , voltas vertis split air conditioner 2.0 ton , easy chair wooden with nylon wire neated seat & back , steel cabinet chandan (minor) , a) wooden class-ii table-01 nos. , b) writing table size 4.6' * 2.8' * 2.5' - 1 nos. , godrej steel shelving rack, size 7.3 ^ prime prime *36^ prime prime *18 , eagle steel cup board:- size 78 "*36"*19" with 4 shelves , steel file rack , godrej navtal pad lock , a) 6 lever-2 nos. , b) 7 lever-2 nos. , c) 7 lever-1 nos. , chandan rack om-40 , chandan steel table (office table) ot-60 g2l2r1 wooden with veener , top , chandan paper tray om-10 , chandan office chair 25 , steel tray without cover size 350 * 250cm , vaccum filter holder, stainless steel, 47 mm dia cap. 250 ml , (a) white board writing system, size 1.5' * 2' - 1 nos, , (b) white board writing system, size 3^ prime prime * 4' - 1 nos. , rotor head + adapter, , (a) tc 453, 4 x 50 swing out rotor head suitable for tc 450 centrifuge, , (b) tc 476: set of reduction adpeter to carry 30 glass tubes suitable for tc 453 rotor head , bunsen burner with stop cock , slotted angel adjustable rack , revolving high push chair , fix visitor's chair (blue gadi), model no. 5vh-101 , ken star microwave oven, 20 acf , wooden table , 3 kva single phase servo stabilizers , fix visitor chair , crompton acgic crest induction cooktop 1500-watt, model: crest
Tender For special repair of existing 02 nos rtcc panels oltcs 02 nos of power transformers including wti oti sys dc battery bank alongwith protection system electric supply by networking with connected items at 66 kv mrs at patiala under ge n patiala
Tender For tender for supply of sitc of lt panel as per item specification document item no 1 at page no 237 , sitc of feeder pillar as per item specification document item no 2 at page no 237 , sitc of smps based float cum boost charger as per item specification document item no 3 at page no 237 , supply of 3.5c x 120 sq.mm. power cable as per item specification document item no 4 at page no 237 , laying of power cable direct in ground as per item specification document item no 5 at page no 237 , laying of power cable of in the existing rcc/ hume/ metal pipe as per item specification document item no 6 at page no 237 , laying of power cable of 1.1 kv grade in the existing masonry open duct as per item specification document item no 7 at page no 237 , laying and fixing power cable on wall surface as required as per item specification document item no 8 at page no 238 , supplying and making end termination as per item specification document item no 9 at page no 238 , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick as per item specification document item no 10 at page no 238 , earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick as per item specification document item no 11 at page no 238 , providing and fixing 25mmx5 mm copper strip as per item specification document item no 12 at page no 238 , providing and fixing 25mmx5 mm g.i. stripas per item specification document item no 13 at page no 238 , supply and laying of 25mm x 5mm copper strip as per item specification document item no 14 at page no 238 , supply and laying of 25mm x 5mm g.i. strip as per item specification document item no 15 at page no 238 , supplying of electric insulated mat of class b as per item specification document item no 16 at page no 238 , supplying of electric insulated mat of class aas per item specification document item no 17 at page no 238
Tender For comprehensive operation and maintenance of the project mainly different class, type and diameter pipes, sluice valves, flow meters, non-return valve, incl.scada system installed at package-1 to 9. work includes replacement of spares for all equipment and maintenance of all civil structures and all electro mechanical installation etc. complete. including submission of periodic mis reports on software. supply of potable water in accordance, all type operations, preventive maintenance, overhauls and repair / break down maintenance for civil / mechanical(incl.pumping machinery) & electrical works. providing nos. of qualified and experienced staff for overall management of o&m work as per detailed specification & obligatory requirement for 60 months. excluding electric power, raw water cost under dist.chhotaudepur& dahod& as per tender.narmada river basin(nr.hafeshwar) based ddsa bulk water pipeline scheme (package-1 to 3) at villages of taluka: devgadhbaria,dhanpur,limkheda,garbada,dahod&chhotaudepur,district: dahod &chhotaudepur.for five years (60 months) o&m (civil+mechanical)(pl see detailed scope of work)
Tender For supply of repair of fire fighting system at telephone bhavan ahmedabad c c -repair and service 100 hp main fire pumpset , repair and service 30 hp jockey fire pumpset , repair and service 105 hp diesel driven fire pumpset , replacement of faulty pressure switches of wet riser system , repairing and servicing of ci body sluice valve size 200mm , repairing and servicing of ci body sluice valve size 150mm , repairing and servicing of ci body sluice valve size 100mm , repairing and servicing of ci body sluice valve size 50mm , replacement faulty length of 150 mm ug c class ms pipe , supply fixing 20mm dia 40mtr long hose reel gm or stainless steel , sitc stainless steel hydrant lugs , replacement fauly branch pipe nozzle 63mm dia stainless steel , painting of valves and fire pipe lines , providing 63 mm dia dia ss delivery hose coupling as per is 903 , providing 2 mm suitable size glass with ss grill on existing housing of 63 mm dia fire hose pipe , refilling of existing 4. 5 kgs. co2 type fire extinguishers , replacement supply of 12v 20 ah sealed maintenance free battery , replacment supply of photo electric type smoke detector in existing fire detection system , replacment supply of ionisation type smoke detector in existing fire detection system , replacment supply of control card in existing fire detection system , replacment supply of zone card in existing fire detection system , replacment supply of power card in existing fire detection system , replacment supply of electronic hooter in existing fire detection system , replacement of 1 mtr long hose pipe for existing fire extinguishers , conducting of fire drill of existing fire detection and alarm system as per bsnl norms , conducting of fire drill of existing fire fight wet riser down comer system as per bsnl norms and fire clearance noc ) /bid number: gem/2025/b/7004304 * /dated: 15-12-2025 & & / bid document1 / 27