Tender For supply, installation and commissioning of water filtration unit for use at centre for biodiversity and conservation studies, osmania university
Tender For supply of transformer oil filtration machine of capacity 1000 lph for service and esp transformers of unit 1 to 7 &amp chp area at kstps, kota
Tender For self contained water cooler. construction of self contained water cooler: self contained water cooler as per is 1475 (isi marked) of cooling capacity - 60 lph at rated conditions and storage capacity 120 liters (i,e 60/120 water cooler.), construction ro frame: ss304 or better, mounting type: freestanding, filtration capacity (in lph): above 50 lph and upto100 lph, storage water tank (inclusive in the scope of supply), yes, storage tank material: stainless steel or same as body material, guaranteed output water quality: as per is 10500 or better, comprehensive warranty for complete unit: 1 year from the date of satisfactory commissioning of the machine, minimum free services during comprehensive warranty / cmc / annual maintenance contract for complete unit: 4 nos. per year, installation and commissioning inclusive in the scope of supply: yes, training and demonstration: the installation and demonstration of the machine at the consignee place shall be carried out as part of installation and commissioning. make . aquaguard,kent,real water or similar.
Tender For supply of portable type loco fume extraction unit 2.2 kw, suction air flow 2200 m3/hr, ? 200 mm suction point, prefilter, activated carbon filter, electrostatic filtration, filtration efficiency 99%, suction hose 2.5 meter self supported 360 degree rotating spring loaded suction arm.
Tender For corrigendum : empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20
Tender For nctps - ii- mi circle – mpm-iii – ventilation system – unit i ab row – carrying out up keeping, routine and continuous monitoring of the unit i ab row & esp i & ii uaf (unitary air filtration) system to improve ventilation effect in tg floors of unit-i ab row and esp i & ii switchgear rooms & cable vault rooms for a period of one year from 01.04.206 to 31.03.27