Get complete information related to latest Hrc Fuse Base Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hrc Fuse Base Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hrc Fuse Base Tenders.
Tender For supply of brake liner, size 0.375 inch x 2.5 inch , brake liner, size 0.375 inch x 3 inch , brake liner, size 0.5 inch x 3 inch , brake liner, size 0.5 inch x 4 inch , g.i.eart clamp, 35 mm2 in pairs , g.i.eart clamp, 50 mm2 in pairs , g.i.eart clamp, 70 mm2 in pairs , coppert rivet, flat,6mmx50mm , coppert rivet, flat,8mmx50mm , coupling bolt with nut,13mmx70mmxm10 , hrcfusebase,32a,415v , pvc cable,1.1kv,1c,cu,1.5mm2
Tender For annual preventive / breakdown maintenance of equipments at 220/132/33kv substations under 220kv oandm division rishikesh - 220 kv switchyardtightening of 220 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 160 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 220 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work, overhauling of mechanism of 220 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 220 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 220 kv take-off assembly/ moving head assembly/rotary head devive etc. (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer, topping up of sf-6 gas in 220 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 220 kv switchyard., 132 kv switchyardtightening of 132 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 132 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work., overhauling of mechanism 132 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete., replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 132 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 132 kv take-off assembly/ moving head assembly/rotary head devive etc (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer., topping up of sf-6 gas in 132 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 132 kv switchyard., 33kv switchyard:tightening of 33 kv bay equipments (cb, line isolator, ct including all connectors of droppers/runner/jumpers), cleaning of 40 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 33 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles, assistance in testing work., overhauling of mechanism 33 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/ runner/ dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 33 kv terminal connector/clamp/jaw/blade etc. and tighgtening of related equipment (including replacement of minor con
Tender For repair and maintenance with spares of hydraulic staffa gear motor,conv. chain drive shaft,main line hydraulic pump,px-160 tyre coupling set, primary drum roll and tail end assemblies of i.r. make feeder breaker (machine no-01) installed at tarmi sdg
Tender For servicing of 220 kv circuit breaker, spreading the required quantity of gravel in switchyard and to carry out other maintenance works at tembhu lift irrigation scheme stage 1a to 5.
Tender For corrigendum : supply of goods, tools & equipmentforan international standard itotin electrician tradeat iti vyara, gujarat, india - electrical machine trainer suitable for demonstrating the construction and functioning of different types of dc machines and ac machines (single phase and three phases). should be fitted with friction brake arrangement, dynamometer, and instrument panel and power supply unit., motor-generator (ac to dc) consisting of: squirrel cage induction motor with star-delta starter and directly coupled to dc shunt generator and switch board mounted with regulator, air breaker, ammeter, voltmeter, knife blade switches and fuses, set complete with case iron and plate, fixing bolts, foundation bolts and flexible coupling. induction motor rating: dc shunt generator rating: induction motor rating: dc shunt generator rating:, motor generator (dc to ac) set consisting of-shunt motor with starting compensator and switch directly coupled to ac generator with exciter and switch board mounted with regulator, breaker, ammeter, voltmeter frequency meter, knife blade switch and fuses etc. set complete with cast iron bed plate, fixing bolts, foundation bolts and flexible coupling. shunt motor rating: ac generator rating:, linear i.c. trainer, digital i.c. trainer, component of typical small hydro power, component of typical water mill, low voltage control and systems. with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, residential and small business systems with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, building control systems and automation with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, industrial control system and automation with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, solar system lab suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, training system predictive maintenance and condition monitoring of electric drives, electric vehicle motors and battery training & test bench, industrial electrical testing facility with circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the testing by the student, ar-vr training set up., portable electric drill machine, pillar electric drill machine, outside micrometer, motorized bench grinder, rawl plug tool & bit, hydrometer, thermometer, soldering iron, copper bit soldering iron, de soldering gun, table vice, ohm meter; series type & shunt type, stock and dies conduit, multi meter (analog), digital multi meter, a.c. voltmeter, milli voltmeter, d.c. milliammeter, ammeter, a.c. ammeter, a.c. ammeter, kilo wattmeter, a.c. energy meter, power factor meter, frequency meter (analog + digital), tachometer with stopwatch, current transformer primary-, potential transformer, growler internal+ external, tong tester / clamp meter, megger, wheat stone bridge with galvanometer & battery 2 nos, earth tester
Tender For providing of required material and maintenance work of 33 kv crompton make c and r pannel (2 no) and breaker (1 no) in the area of edd deoband