Get complete information related to latest Hsc Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hsc Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hsc Pump Tenders.
Tender For major repairs and replacement of civil and mechanical items, laboratory items in waddepally filter bed in gwmc limits - ls amount for new rates after receiving quotations for motor, vfd and pump , support & installation charges installation & programing for vfd at required site , supply and delivery of fuji electric make vfd, capacity: 369hp/275kw, 400v drive design and rated specifications for 50'c, no derating required, multi- rating capacities with heavy duty and normal duty applications for 50'c and for 40c site ambient conditions suitable for load type of 3-phase induction motor and pmsm/synchronous motor drive module with environmental resistance 3c2 coated pcbs and copper bars with plating for longer life in indian environment, drive component design life is 10-years, dual channel rs-485 port, vfd dimensions: 536.4(w) 1000 (h)*366(d). , support & installation & commissioning charges of hscpumpset of cf8m stainless steel impeller along with casing at requested site in alignment wih existing motor and other related necessary mechanical accessories: 1) pair of coupling with bolts,2) bed plate, 3) foundation bolts & 4) coupling and guard , etc as per site requirement , supply and delivery of wilo mather & platt scp (300-380)or (300-400) ha make horizontal splitcasing pumpset of cf8m stainless steel impeller along with casing duty : 300/39 discharge -947 m3/hr @36-45m head suitable for 240 hp/180 kw kirloskar motor
Tender For repair / maint / replacement of existing star delta starter / contactor, lowering, lifting of submersible pump set, repair to irp and miscellaneous water supply item at 3 afsr, nkp, kahikuchi area under ge (af) borjhar
Tender For supply erection, testing and commissioning of 227 m3/ hr. (50000 gph uk) or higher capacit y hscf pump set with 75hp (or higher capacity) motor 4p/tefc/ie3 horizontal foot mounted type with ratin g 415v, 50hz, 3 phase along with soft starter panel, pump set specifications shall conform to pcee/grc's l atest specification and as per site requirement annexure by consignee. the cost is inclusive of dismantling, making concrete foundation work, supply of suitable size foundation bolts and all requisite materials. [ war ranty period: 30 months after the date of delivery ]
Tender For supply erection, testing and commissioning of 545 m3/ hr. (120000 gph uk) or higher capaci ty hscf pump set with 270hp (or higher capacity) motor 4p/tefc/ie3 horizontal foot mounted type with rat ing 415v, 50hz, 3 phase along with soft starter panel, pump set specifications shall conform to pcee/grc's latest specification and as per site requirement annexure by consignee. the cost is inclusive of dismantling , making concrete foundation work, supply of suitable size foundation bolts and all requisite materials. [ w arranty period: 30 months after the date of delivery ]
Tender For supply erection, testing and commissioning of 227 m3/ hr. (50000 gph uk) or higher capacit y hscf pump set with 120hp (or higher capacity) motor 4p/tefc/ie3 horizontal foot mounted type with rati ng 415v, 50hz, 3 phase along with soft starter panel, pump set specifications shall conform to pcee/grc's latest specification and as per site requirement annexure by consignee. the cost is inclusive of dismantling , making concrete foundation work, supply of suitable size foundation bolts and all requisite materials. [ w arranty period: 30 months after the date of delivery ]
Tender For work contract for refurbishment of colony potable pump flowmore-make hscpump model m590 bd 125x100, four stage, by adopting reclamation and replacement technique installed at 2x600 mw, sstpp, mppgcl, dongalia
Tender For comprehensive operation-maintenance and security of hscf pump sets with coordinated electro-mechanical accessories and equipments etc. complete at khodu, raigadh and karangadh hw of s2:s3 rwss, dist. surendrnagar for 12 months
Tender For tender for shifting and installation of scf pump and accessories , supply, installation, testing and commissioning of hscf pumping machinery , o & m of pumping machinery
Tender For supply and delivery of safty arrangements for north east mansoon in virudhunagar municipality - supply and delivery of suction pipe including cost of all charges etc.,complete, supply and delivery of suction foot valve including cost of all charges etc.,complete, supply and delivery of nylon rope including cost of all charges etc.,complete, supply and delivery of torch light including cost of all charges etc.,complete, supply and delivery of power saw including cost of all charges etc.,complete, supply and delivery of crow bar including cost of all charges etc.,complete, supply and delivery of spader including cost of all charges etc.,complete, supply and delivery of iron tasla including cost of all charges etc.,complete, hsn:84137010 model no: eterna 1800bw kirloskar make 1.8kw/2.5hp 1 ph 230v waste disposer pump , size :65mm, removal of centrifugal pumpset/ jet pumps/ submersible pumpsets and its accessories from borewell/ open well for attending repairs 50% of the rates mentioned under item 17 (a), (b) and (c) may be allowed for the respective horse power twad sor 22-23 pg.no:308, supply and delivery of submersible centrifugal sewage non-clog pumps, vertical spindle type pump , wear resistance with submersible motor for the various duty conditions. pump shall be capable of handling min 100 mm solid size with sewage specific gravity of up to 1.05. pump shall be of robust construction, liquid passages shall be finished smooth and designed as to allow free passage to solids. pump impeller should be of non-clog semi open type , single vane /multi vane preferably contra bloc or vortex impeller design. double mechanical seal with silicon carbide faces should beprovided to protect the motor from ingress of sewage along the shaft. the critical speed of the rotor shall be at least 30% above the operating speed. pumps should have double bearings between the pump & motor. the bearings life shall be minimum 100,000 hrs of operation with greased for life. pump should be provided with automatic coupling device including pedestal, duck foot bend, stainless steel guide pipe or related accessories of suitable size to facilitate lifting and lowering into guide rails for easy maintenance. pump shall be provided with a stainless steel lifting chain conforming to bs 970 gr 304. pump speed shall be of 9600 rpm for high duty pumps and 960/1450 rpm for low duty pumpsets. casing and impeller should be of ci gr. fg 260 :is210 more preferably with hardened impeller.shaft shouldbe of stainless steel aisi 410. all the fasteners and bolts shall be of aisi 410.the submersible motor shall be operated with 3ph, 415 v(+or 10%), 50hz(+or-5 %) dry induction type. motor shall be capable of giving rated output without reduction in the expected life span when operated continuously. the rotating assembly shall be dynamically balancedas per standards. the starting current of the motor shall not exceed 200% of rated full load current for star / delta or ats starting under any circumstances .the motor shall be suitable for full voltage star delta / ats starting. the locked rotor current of the motor shall not exceed 600% of full load current unless otherwise specified. motor shall bedesigned to withstand 120% of rated speed for two minutes without any mechanical damage, in either direction ofrotation. the motor vibration shall be within the limit specified in applicable standards . motor should be of ie2,explosion proof compatible for vfd operation together with star-delta /ats starter, protection against increase instator winding temperature (15 deg celsius), bearing temperature, leakage in the stator housing and terminal box shallbe provided and to be suitably interlocked with the control panel for tripping the pump in case of increase intemperature beyond set limit.insulation class shall be of class h and degree of protection shall be of ip 68 as per is 4691. motor shall be suitablefor continuous operation in fully submerged or partially submerged condition.t