Get complete information related to latest Ht Breaker Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ht Breaker Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ht Breaker Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :38843176 Due date: 25 Jan, 202525 Jan, 2025 23.70 Lacs
Tender For repair and maintenance to lt cable, external electric power transmission system, security light control panel, cable, high mast and other miscellaneous works and certain em maint works at afs site p,r under ge af thane

CTN :38175404 Due date: 13 Jan, 202513 Jan, 2025 NA
Tender For corrigendum : supply of core switch , distribution switch , 24 port gigabit non poe access switch , 48 port gigabit non poe access switch , 8 port gigabit non poe access switch , 40g qsfp fiber modules of same make as of switches , 10g sfp plus fiber modules same make as of switches , next gen firewall ngfw , network management software nms for 100 nos of device , network access control , endpoint detection response software for 920 users. , cat6 utp cable 305 mtr , 24 port unloaded cat6 jack panel , cat6 io modules , cat6 utp patchcords of 1 mtr length , cat6 utp patchcords of 2 mtr length , dual port faceplate along with 3x3 pvc gangbox , single port faceplate along with 3x3 pvc gangbox , 12 core single mode armored outdoor fiber cable , lc lc patch cord , 24 core fully loaded liu lc lc type , 800 mm x 1200 mm 42 u smart rack with 3.5kw ac unit , 42 u free standing cabinet , 12 ru wall mount cabinet , 9 ru wall mount cabinet , pvc conduit pipe 25 mm dia conduit , pvc conduit pipe 32 mm dia conduit , 50mm high density polyethylene pipe underground , 40mm gi conduit , ofc route markers , rcc road concrete cutting and repair , digging and refilling of hard and soft soil concrete bricks. , nms sever , active directory server , backup server , centralized edr server , 20 tb usual storage scalable , automated data backup tool , 86 inch interactive display , floor stand for 86 inch display , portable thin client , laptops , 3 core 2.5 sqmm armoured power cable , 20 kva ups , 6 kva ups , integration of services and maintenance of it infra

Central Government / Public Sector

CTN :38781938 Due date: 13 Jan, 202513 Jan, 2025 36.83 Lacs
Tender For custom bid for services - maintenance of plant equipments and safety systems at erode lpg bottling plant-part a maintenance of conveyor systems, online equipment, tld- 1 daily:- calibration of all filling machines and check scales, checking the condition of telescopic conveyors, pneumatic hoses, conveyor chains regularly, carrying out all required preventive maintenance checks and to replace the worn out chain or chain links and conveyor wear strips with new one as and when required, to ensure nil breakdown of telescopic conveors and chain cuts and to attend to the chain cuts immediately if required. before starting of shift cleaning of all photo sensors and cameras of vision readers deduction of rs.50/- for every 15 minutes in every instances beyond 15 min stoppage on account of chain cut and telescopic conveyor breakdown, any mechanical failures. 720 shift, daily:- ensuring regular maintenance of sprockets, shafts for all types of gear boxes (planetory, nord,worm type), conveyor counter weights and replacement of the same as when it is worn out in order to ensure nil break down in the shift and to replace the same in case of breakdown during the shift. the item includes regular inspection and greasing for smooth operation, inspecting for looseness if any, and inspecting for alignment of shafts and sprockets. oiling of drive shaft bearing of dus and idler shaft wheel in each shift. deduction of rs.50/- for every 15 minutes in every instances beyond 15 min stoppage on account of each production loss on account of sprocket/shaft breakdown. 720 shift, 3 regular maintenance of filling machines and carousel inline equipment, pre oring leak detectors, pre oring replacement machine, cold repair machines, deshaping machines, purging unit, evacuation unit, degassing unit, vcme, nanocut dosing unit, xtra tej dosing unit, 5kg, 47.5 kg and 425kg filling facilities and also updating history cards for above equipment. deduction of rs.50/- per cumulative hour beyond 15 min shall be made for each production loss on account of any breakdown in these machines or any lpg leakage observed in these machines. updation of maintenance log as per format provided by officer in charge. assistance for carrying out water draining operation under the supervision of iocl in charge need to be done. for this work, the personnel should report exactly at the start hours of the shift of the day at lpg pump house. 720 shift, 4 maintain leak free conveyors: leakages from the running conveyors is to be stopped or it is to be directed into soap solution trays , the soap trays, running trays, idle trays to maintained in leak free condition. ensuring that the necessary tray overflow pipelines provided in the floors are are not choked and excess soap water is collected /drained properly to ensure nil soap solution leakage inside the floor area. there should not be leaks from the conveyors other than from drive sections. (fabrication/modification works if any will be paid separately). if water leakages are appearing because of washing unit or inline bath the proper arrange to be made for arresting the same 720 shift, 5 mechanically & electronically qualified assistance on daily basis for the maintenance & necessary routine repairs of on-line mechatronic equipments installed throughout the conveyor line and carousel (photo sensors, load cells, power/communication cabling, communication bars, electro-pneumatic control panel, relay cards, limit switches, magnetic sensors, solenoid coils, timers, earthing wires etc) and its replacement with new one supplied by iocl whenever required. maintaining necessary records for the calibration of the equipment (measurement systems required to be stamped by the authority of legal metrology) is a part of this job. this also includes the record keeping of stock of these components and the periodicity of its replacement. 6 maintenance of loading/ unloading/filling area stoppers, pushers, diverters, converger assemblies, limit swi

CTN :38758814 Due date: 13 Jan, 202513 Jan, 2025 NA
Tender For repair / maintenance of outgoing 1000 amp lt control panel unit 3 and unit no 5 and repair servicing to vacuum circuit breaker of 2.5mva power transformer unit no 01 and unit no 02 and ht control panel 01 and 02 installed at lift irrigation station r

Central Government/Public Sector

CTN :38587466 Due date: 04 Jan, 202504 Jan, 2025 19.66 Lacs
Tender For repair, maintenance, and installation of plant/ systems/equipments (version 2) - 285 instrument erection contract for revamping of flow lab at instrument workshop at rcf trombay unit; as per sow; as per sow- 1 fabrication, erection & installation of cable tray 50 mm width with necessary support m s angle 50 mm. this job includes two coat of primer and two coat of anticorrasiveepoxy coats. supply of primer and paint to be included and fabrication, erection and installation of cable tray. 50 mtr, 2 supply and installation side mounted glass tube level indicator approx 2.5 mtr length with high and low level switch adjustable over the full length. 1 no, 3 supply and installation and commissioning of centrifugal pump flow capacity of 30 m3/hr head 45 meter suitable for vfd drive 1 no, 4 magnetic flow meter 0 to 50 m3 /hr, 4" size flanged 150# rf, accuracy 0.1% with calibration certificate 1 no, 5 4" size ss material, 150#, flanged on/off valves with actuator, limit switch indication dome, solenoid valve 4 no, 6 vfd with panel and start /stop pb, and speed control 1 no, 7 pressure gauges 1 no, 8 supply, installation of piping suitable for the flow skid in sizes 4" and as per requirement 1 lot, 9 flow totalizer with contacts and set rest function 1 no, 10 panel for skid operation with pb, lamps, selector switch 1 no, 11 supply, installation of pvc coated cu tubing with necessary fittings for 4 valves 80 mtr, 12 supply, installation of air distribution header 6 points stainless steel 1 no, 13 supply, installation of 50 mm wide x 30 mm x 2 mm thick gi cable tray 100 mtr., 14 supply, installation of 100 mm wide x 30 mm x 2 mm thick gi cable tray 100 mtr., 15 supply, installation of layingof signal and power cables 300 mtr., 16 1 pair x 1.5 mm2 signal cable 300 mtr., 17 power cable for motor existing cable to be reused as per requirement 500 mtr, 18 spool pieces with one end flanged connection and other end with triclover coupling in ss304 of various sizes as below with 10d and 5d lengths. set of spool pieces shall iclude following sizes: 6", 4", 3", 2.5", 2", 1.5", 1", 3/4", 1/2" each in quantity 2 numbers 1 lot removal jobs 1 structural steel which includes ms ladder tray, stantion, alluminium cable trays 300 kg, 2 cable- signal , power cable removal 100 mtr., 3 level indicator 2 no, 4 existing piping and fittings 1 lot, 5 removal of existing pipe and fittings 1 lot

CTN :38718235 Due date: 16 Jan, 202516 Jan, 2025 NA
Tender For repair of power supply card fcbc - repair of power supply card fcbc , repair of ac dc control card fcbc , repair of display card fcbc , repair of ac voltmeter fcbc , repair of dc voltmeter fcbc , repair of dc relay fcbc , repair of bridge rectifier fcbc , repair of transformer fcbc , repair of lc filter fcbc , repair of bty control panel fcbc

Central Government/Public Sector

CTN :38157116 Due date: 10 Jan, 202510 Jan, 2025 1.30 Crore
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous