Get complete information related to latest Ht Switch Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ht Switch Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ht Switch Repair Tenders.
Tender For tender for supply of integration of video conferencing and audio system - director board room- 85 or 86 inch professional display , director board room- customized floor display mount for sl.no 1 item , director board room- cisco room kit eq , quad cam , make-cisco , model- cs-kit-eq-k9 , director board room- 3years sntc-8x5xnbd sntc-8x5xnbd room ki , make-cisco , model-con-snt-vsxlbmdc , director board room- cisco table microphone with jack plug , make- cisco , model- cs-mic-table-j , director board room- 8 port poe switch , director board room- 4x1 4k60 4 is to 4 is to 4 hdr av switcher , director board room- 1x4 hdmi da , director board room- modular sockets , 2 x hdmi , 2 x usb , 2 x power face plates with back box , director board room- professional hdmi male to male cables , 10 meter , shall support 4k uhd signals , director board room- professional hdmi male to male cables , 1.8 meter , shall support 4k uhd signals , director board room- professional usb active extension cables , 3.0 , 5 meter , director board room- usb 3.0 hub , director board room- professional usb active extension cables , 2.0 , 10 meter , director board room- chipping of floor and concealing with similar tile , 2inch width x 2 meters , installation , configuration , testing and documentation - director board room , 2nd floor old vc room-43 inch well display with anti-glare coating , 2nd floor old vc room-43 inch well display floor mounting kit , 2nd floor old vc room-all-in-one video bar with remote control supporting 4k , 2nd floor old vc room-3 years partner premium support for video bar , 2nd floor old vc room-wired expansion microphone for supporting video bar , 2nd floor old vc room-8 port poe ethernet switch , 2nd floor old vc room-8x8 4k60 4 is to 4 is to 4 hdr av switcher , 2nd floor old vc room-av system control processor with keypad , 2nd floor old vc room-table top kit for av control processor , 2nd floor old vc room-touch display with desktop mount , 2nd floor old vc room-usb 3.0 hub , 2nd floor old vc room-modular sockets , 2 x hdmi , 2 x usb , 2 x power face plates with back box , 2nd floor old vc room-professional hdmi male to male cables , 15 meter , shall support 4k uhd signals , 2nd floor old vc room-professional hdmi male to male cables , 10 meter , shall support 4k uhd signals , 2nd floor old vc room-professional hdmi male to male cables , 5 meter , shall support 4k uhd signals , 2nd floor old vc room-professional hdmi male to male cables , 1.8 meter , shall support 4k uhd signals , 2nd floor old vc room-professional usb active extension cables , 3.0 , 5 meter , 2nd floor old vc room-professional usb active extension cables , 2.0 , 10 meter , 2nd floor old vc room-chipping of floor and conceiling with similar tile , 2inch width x 2 meters , installation , configuration , testing and documentation -2nd floor old vc room , 2nd floor old vc room-acoustics- supply and installation of 9 mm chroma panels , fire resistance - astm e-84 class a euroclass b-s1 , d0 , material -100 percent pet min. 60 percent recycled , backed with 8 mm ply , 2nd floor new vc conference room- acoustics- supply and installation of 9 mm chroma panels , fire resistance - astm e-84 class a euroclass b-s1 , d0 , material -100percent pet min. 60percent recycled , backed with 8 mm ply , 2nd floor 308 mini conference hall12x optical zoom ptz camera with usb support for software based vc integration , 2nd floor 308 mini conference halldigital audio mixer , 2nd floor 308 mini conference hall4x2 hdmi matrix switcher , 2nd floor 308 mini conference hallhand held wireless microphones , 2nd floor 308 mini conference hallheadworn wireless microphones , 2nd floor 308 mini conference hallwall mount speakers , 2nd floor 308 mini conference hallaudio amplifier , 2nd floor 308 mini conference hallcables and connectors as required for interconnecting , installation , configuration , testing and documentation - 2nd floor 308 mini conference hall , gdg ground floor conference hal
Tender For replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the energizer without
Tender For supply of sitc of ip epabx system with 05 years - supply installation testing commissioning sitc of dual server gateway based ip pbx system. , sitc of executive ip phones with 2 way speaker phone , sitc of poe based ip phones , sitc of corded analog phone with cli , sitc of management platform inclusive of management software , sitc of pc based ip operator console , sitc of intermediate distribution frame idf 100 pairs , sitc of intermediate distribution frame idf 20 pairs , sitc of 24 port l2 plus managed poe plus switch with fully loaded sfp module single mode transceiver , sitc of cat-6 cable industrial grade including capping, casing, conduiting fasteners with all materials. , sitc of cat 6 utp patch cord 3 meter each , sitc of power cable , supply and laying of 0.5 mm, 50 pairs telephone cable , supply and laying of 0.5 mm, 100 pairs telephone cable , supply and laying of 0.5 mm, 20 pairs telephone cable , supply and laying of 6 core armoured single mode ofc cable including capping, casing, conduiting fasteners with all materials. , sitc of rack mounted ups 2 kva line interactive, 30 min back up for network switches , sitc of 42u rack for epabx server its accessories with cable manager 2 pdu , sitc of rack mounted ups 5 kva online, 60 min back up for epabx servers and gateways , electrical distribution system as per site requirement , rack mounted load transfer switch , surge protection device spd , earthing system , liu 6 core fully loaded with pig tail , 12u switch rack wall mount , io boxes with dual rj45 ports with gang box and cover , io boxes with dual rj11 ports with gang box and cover , deployment of one experienced and qualified technical personnel at the work site during working hours for 02 months after commissioning of the system. , sitc charges of all the eqpt systems associated with ip epabx mentioned in this bill of material and operational and technical trg charges for 5 personnel for 3 day including all cost components
Tender For supply of delivery of of 3no mccb of acdb at 400kv shujalpur ss - 400 amps mccb 4 pole make cands and motor operator for remote , ampere meter , volt meter , aluminum bus bar 35x5 , tnc switch , selector switch , indicating lamp led ryb , indicating lamp led green , push botton 2no, 2nc red and green , g-make acb arcing fixed contact , g-make acb arcing moving contact
Tender For supply of soil dna isolation , water flow meter , line quantum sensor with data logger , hand held crop greenseeker for ndvi measurement along with charging facility and remote switch kit , fruit juice mixing tank 73 , fruit pulper 27 , canopy analyzer , abney level instrument
Tender For supply of 19 rack mountable managed industrial ethernet switch having number of port along with required sfp , 19 rack mountable 24 port patch panel , stp patch cord, 1 meter length , 19 rack mountable 24 port (12 pair) light interface unit (liu) for 9/125? m(os2) single mode fibre. , din rail mountable 6 port (3 pair) light interface unit (liu) , single mode fibre optic patch cord, 0.5 meter length , single mode fibre optic patch cord, 2 meter length , single mode fibre optic patch cord, 15 meter length
Tender For bid to ras supply of shocker pipe , main switch 32 amp 3 phase , cut out 100 amp , ampere meter , volt meter , starter bentex 3 phase , starter oil , channel 4 inch into 2 oblique 8 , rubber wheel 12 inch , seat repairing kit , battery 90 ah large , back light round , horn 12 v , horn bottom , battery terminal , terminal patti , meter holder with bulb , double point switch , wire 1 and half mm roll of 100 meter , wire 2 mm roll of 100 meter , insulation tape , tank cap swaraj , tank cap , air cleaner glass