Tender For corrigendum : supply of 2 point 4 per 1 point 7 f pre shaped tip low profile shaft neuromicrocatheter with 0 point 0165 inch inner and 0 point 014 guide wire compatible like excelsior sl 10 , stent neuro self expandable braided for intracranial aneurysm neck remodeling with delivery wire and delivery micro catheter 3 point 5 x 18 mm such as lvis from microventionpoint , stentretriever neuro for mechanical thrombectomy non detachable self expandable nitinol based open , catheter micro dmso compatible with 1 point 5 f distal od 2 point 7f proximal od 165 cm length such as marathon from medtronic , stent carotid self expandable dual layered open cell with outer ptfe mesh such as c guard from inspire md , microcatheter braided two to tip marker steam shapeable tip distal tip of at least 2 point 1 f suitable for neurointervention having inner diameter of at least 0 point 027 inch , 3 d self detachable neuro embolisationloils 5 to 8mm 5 to 20 cm length for framing of neptured aneurysm like target 360 stryker , soft tip intracranial 6f guiding catheter for distal smooth navigation like neuron penumbra , polyvinyl alcohol particles 150 to 250 microns , polyvinyl alcohol particles 250 to 350 microns , polyvinyl alcohol particles 350 to 500 microns , polyvinyl alcohol particles 500 to 750 microns , syringe luer lock polycarbonate construction for use with sclerosants etc 10 ml , percutaneous catheter introducer sheath set 11 cm to assorted sizes , histoacryl glue n butyl cyanoacrylate , hydrophilic coated guide wires suitable for negotiating tortuous vascular anatomy with j curve tip of 0 point 035 diameter and 150 cms length , guidewire amplatz ultra stiff 0 point 035 inch diameter 260 cm or more length available with 1cm coma 3cm and 6 cm floppy tip segment , cobra 1 c1 visceral braided torque control catheter 5 point 0 french 65 cms long permitting 0 point 035 inch guide wirepoint , kampe access catheter 5 f 65 cm length , flow diversion embolisation device for intracranial aneurysm like silk vista per surpass per pipeline per derivo , microguidewire nitinol constrction hydrophilic coating angled tip 0 point 014 inch diameter at least 180 cm length , microcatheter l 110 per 130 cm od distal 2 point 4 per 2 point 7f for peripoheral intervention glide m coating preloaded with 0 point 021 guide wire like progreat , haemostatic sponge gelatin 80 mm long 50mm broad 10 mm thick , semiautomatic core biopsy gun set with 02 throw lengths of 10mm and 20 mm in a single //bid details2 / 26
Tender For corrigendum : neurovascular item for neurosurgery department - super-selective high flow infusion catheters for cerebral/spinal avms (compatible with n-butyl cynoacrylates)- flow guided 150 - 180 cm long graded shaft stiffness should be compatible with 0.007, 0.008, 0.010"micro guide wire should have three segments, 1.2f, 1.5f, 1.8f, one tip marker microcatheter, 167 cmhybrid braided catheter for liquid embolic injection coil reinforced and braid reinforced0.0165/0.013-inch id, 0.014 compatible guidewire dmso compatible2.1f proximal od, 1.3f distal od, super-selective high flow infusion catheters for cerebral/spinal avms (compatible with dmso) with detachable tips 150-180 cm long graded shaft stiffness should be compatible with 0.007, 0.008, 0.009, 0.010" micro guide wire should have multi-segmented construction specify hydrophilic coating specify detachment mechanism, 1.2f, 1.5f, 1.8 f, 1.2 f with combined packing of catheter and compatible wire, 1.5 f with combined packing of catheter and compatible wire, super-selective high flow infusion catheters for cerebral/spinal avms (compatible with dmso) without detachable tips150-180 cm long graded shaft stiffnessshould be compatible with 0.007,0.008, 0.009-inch micro guide wirespecify hydrophilic coating, 1.2f, 1.3f, 1.5f, 1.8f, selective infusion micro catheters (compatible with particulate embolic agents e.g., pva particles) selective infusion micro catheters (compatible with particulate embolic agents e.g., pva particles relatively wide inner id 140-150cm long, distal tips-2f, distal tips-2.2f, distal tips-3f, distal tips-4f, delivery microcatheterproximal od 2.95 for distal od 2.6fr 0.025 id with 160cm long compatible with reperfusion catheters, two tipped micro-catheters compatible with dmso/glue, dmso compatible & 156 cmlong two tip marker coils reinforced microcatheter 0.021-inch id & steam shapeable7 segments along the shaft length 2.5f proximal od, 2.0f distal od, dmso compatible & 156 cm two tip marker coils reinforced microcatheter0.027-inch id & steam shapeable-7 segments along the shaft length- 3.1f proximal od, 2.6f distal od, dmso compatible two tip marker microcatheter 156 cm length, 0.0165-inch idhybrid braided catheter for aneurysm coiling and liquid embolic injection- coil reinforced and braid reinforced-0.014 compatible guidewire-steam shapeable- 2.1f proximal od, 1.6f distal od, two tipped microcatheter compatible with dmso/glueproximal od 2.5 for distal od 2.2fr length 160cm, dmso compatible single tip marker microcatheter, 167 cm length, 0.0165/0.013s inch id- hybrid braided catheter for liquid embolic injection- coil reinforced and braid reinforced--one tip marker microcatheter, 167 cm-, 0.014 compatible guidewire-steam shapeable-dmso compatible- 2.1f proximal od, 1.3f distal od, dmso compatible two tip marker coils reinforced microcatheter-0.017 inch id, 150 cm length-steam re-shapeable with 0.41cc dead space-7 segments along the shaft length, flow dependent micro catheter with distal tip of 1.2 f; non dmso compatiblefor access through distal, tortuous vasculature. for regional infusion of therapeutic agents or embolic materials like glue, pva etc., flow dependent micro catheter with distal tip of 1.5f non dmso compatible.for access through distal, tortuous vasculature. for regional infusion of therapeutic agents or embolic materials like glue, pva etc., atraumatic micro guide wires with torque device for use with micro catheter: sizes: 0.007 & 0.008 lengths: 150-180cms should have soft platinum floppy tip coating with hydrophilic polymer should have wires with varying degree of shaft support, sizes: 0.007 straight, sizes: 0.007 pre shaped, sizes: 0.008 straight, sizes: 0.008 pre shaped, atraumatic micro guide wires with torque device for use with micro catheter: sizes: 0.007 & 0.008 lengths: 150-180cms should have soft platinum floppy tip coating with hydrophilic polymer should have wires with varying degree of shaft suuse with mic