Tender For supply of 5 kva single phase portable diesel genset, control panel-manual/amf, fuel tank capacity- 15 ltrs., engine model- kd441-gs12, type- direct injection, 4 stroke, bhp- 8.2, air cooled, starting system- 12v dc, 35 ah, alternator make- cropton, voltage- 230 volts, 50 hz.
Tender For corrigendum : repairs/ day to day maint of street lights/solar street light/ pole/ cable junction boxes/ timer switches/ search lights rusted steel poles alongwith repairs/ day to day maint of standby dg set/ amf panel/control panels /cable/dg set earthing at darj
Tender For repair/ maintenance of eot/hot crane , lift , boom barrier, various dg sets , amf panel, control panel maint of etp, motorised door of hangers, and other miscellaneous work etc at different location at tech area 11 brd af stn ojhar
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar