Get complete information related to latest Hydroacoustic System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hydroacoustic System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hydroacoustic System Tenders.
Tender For corrigendum : supply installation testing and commissioning of 01 no of table top powder xrd at school of physics smvdu kakryal katra - supply and installtion of table top powder xrd with detailed specifications as follows:, x-ray generator: max. continuous rated output: 600 w guidance based software system, voltage: 20- 40 kv with increment of 1kv / current: 2 15ma with increment of 1ma (variable voltage and current). ht stability better than +/-0.01% for mains stability +/- 10 %.x-ray tube:cu target with 1000w and k-beta filter, should be upgradable for cr, co & fe.goniometer:high precision, vertical type, goniometer with theta two theta geometry, range: -3 to +1400 or better, radius: 150mm, scanning speed: 0.01 ~ 100 degree/min, max scanning speed: 500deg/min, sollar slit(incident & receiving): 2.5 deg, incident height limiting slit(dhl): open (10mm), necessary software and hardware for diagnostics capable of checking the equipment parameters/ calibration etc.divergent slit:variable to keep the x-ray illumination of sample same from low angle to high angle of 2 theta. detector:high speed silicon strip detector, it should work in 1d mode. also fluorescence reduction mode should be available. cu efficiency 99% samples holder: glass (0.2mm) qty 20, glass(0.5mm)-qty -20, aluminum (20 mmx20 mm) hole - qty 20, low background si sample holder- qty 02software: guidance based software system software should have a provision for the following: 1) all active operations should be controllable through the software 2)simultaneous data collection and data processing facility. facilities for peak search, peak match, and pattern treatment such as data smoothing, background subtraction, 2 correction, 3d multiple pattern display, k 2 calculation and removal, integrated intensity calculation, relative intensity ratio (rir) quantitative analysis and crystallite size. xrd-rietveld analysis. hybrid search / match algorithms which combines the features of peak based and profile based, phase identification techniques. it offers improves, qualitative analysis performance which makes, identification of crystalline phase with preferred, orientation or a complex lattice deformation.computer systems:latest pc along with latest operating system (latest 8.1 or 10), laser colour printer, necessary software for operation and data acquisition, analysiscod-data base:software is compatible with cod (crystallography open database) which is available on internet. (internal /external ) chiller:suitable compact for smooth running of xrd ups: online 6kva with 30 mts. backup.installation and commissioning: the instrument to be installed tested and commissioned by representative of supplier at our premises to the satisfaction of user free of cost.training: the supplier should provide the training on site free of cost.safety:the system should be housed in a high safety standard radiation enclosure as per international norms.warranty: at least one year from the date of installation(the supplier should provide the certificate of successful installation of benchtop xrd from the head of the department of concerned government labs/ institutes. )
Tender For corrigendum : supply of hard hat mount voltage detector (honeywell make) hv detector is required in the field units of operation circle dehra under chief engineer (op.) kz zone, dharamshala
Tender For corrigendum : supply of bty capacitor tester bct-700a elake , elak automatic 12v 24v charger , acid gravity tester hydormeter , t type wrench set 06mm to 16mm , 20v lithiumine cordless impact drill machine p20s , impact screw driver bit set , acid proof rubber mat 18x5 feet , cutting plier ingco , pros kit 15305b for repair , fluke non contact voltage tester , dc voltage detector for vehs 0.8 to 100 volt , ingo 5 pcs electrical test kit cos23056 , soldering iron 230volt 500 watt heavy duty , cordless screw driver ingco 17 pcs , carry bag for tools size 18 inch ingco stanely , rachet combination spnr set 06mm to 32mm
Tender For corrigendum : tn-23018 supply of fire fighting equipment and spares, kstps, kota. - supply of fire-fighting equipments and spares for kstps, kota, discharge tube for dcp 5kg. fire extinguisher (18" ft. hose length) cartridge type, discharge tube for dcp 10kg. fire extinguisher (24" ft. hose length) cartridge type, hose with horn for co2 extinguisher 22.5 kg (5 mtr. hose length) hose is connected with end connection on both side. co2 gas is discharged through this hose. one end is connected to discharge horn., hose with horn for co2 extinguisher 4.5 kg (1 mtr. hose length) hose is connected with end connection on both side. co2 gas is discharged through this hose. one end is connected to discharge horn., discharge tube for 25 kg dcp wire braided hose (3 meter length), supply of ss304 seat valve assembly with rubber washer for 63mm hydrant valve , as base plate sheet (metallic) with base plate check nut, with neoprene rubber wash- er for spindle., supply of c.i is: 210 hand wheel for 63mm hydrant valve, supply of q.b detector 1/2" size 79deg it operates as a valve by allowing the flow of water contained in a fire qbd system when the heat sensitive element (glass bulb or fusible link) is operated., supply of ss304 63mm female outlet for 63mm hydrant valve, supply of ss304 63mm bonnet for 63mm hydrant valve, supply of ss304 63mm spindle for 63mm hydrant valve, discharge tube with nozzle for foam 9 ltr. fire extinguisher (1.5 mtr. hose length), insulated hand gloves with working voltage of 17000 volts and proof voltage 25000 volts as per is 4770, gumboot with steel toe cap moulded pvc to protect against oil acid and alkalie re- sistance confirming to is 15298, 63mm rubber washer for female outlet of hydrant valve, supply of s.s-304 63mm single headed fire hydrant valve as per is: 5290, vtype-a, isi marked. having pvc male blank cap with chain., ceramic wool fire blanket white density: 128 kg/m3, size : 610x7100 mm; thick- ness =25 mm. weight : 3130 gsm thisckness test metod : astm d 1777& weight test metod : astm d 3776 tensile strength in kgs (1 x4 ) = 10 to 16 psi, potassium based aerosol ; first responder produces an exceptionally effective, ultra fine aerosol that provides extremely fast knockdown and rapid sup-pression of fires. aerosol mass 0.5 kg. length 142.9mm with actuator 174.6 mm.;diameter 80.98 mm.; delay time 3.5 seconds &discharge time 20 sec.operating temp. -29 c to +60 c; classification code : 1.4s potassium based aerosol ; first responder produces an exceptionally effective, ultra fine aerosol that provides extremely fast knockdown and rapid sup-pression of fires. aerosol mass 0.5 kg. length 142.9mm with actuator 174.6 mm.;diameter 80.98 mm.; delay time 3.5 seconds &discharge time 20 sec.operating temp. -29 c to +60 c; classification code : 1.4s, high velocity spray nozzles 80 , nicalchorme plated, ul listed, 3/4 bspt, high velocity spray nozzles 90 nicalchorme plated, ul listed, 3/4 bspt, high velocity spray nozzles 120 nicalchorme plated, ul listed, 3/4 bspt, hose reel with horn for co2 length : 15 mtr. hose reel made of ms having unique ball valve shut of devise with breaded hose & nozzle. drum red/ hose pipe black.drum length 15 mtr. , hose pipe length and diaas per requirement. test pressure 10 kg./cm.sq of hose pipe. control nozzle at the end is attached to control flow & direction., discharge tube with nozzle for foam 45 ltr. fire extinguisher ( 4.5 mtr. hose lenght)
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For supply of non-contact high voltage detector (q3) , digital earth resistance meter (q3) , digital light meter (q3) , true rms clamp meter (q3) , digital multimeter (q3)
Tender For supply of chemistry lab equipment - procurement of chemistry lab equipment, uv visible spectrophotometer equipped with integrating sphereapplicable for both solid and liquid sample, powder sample kit, diffuse reflectance standards of 2%, 5%, 10%, 20%, 50%, 100%, neutral density filter to obtain linearity for transmittance, and pc control(configuration: insight software for instrument along with core i7 processor and 512gb ssd), electronic balancestainless steel weighing plate, measuring range resolution: 0.001 g, weighing capacity measuring range 120 g, parameter 0.001 g readability (1 mg), capacity 120 g, outside size 20.5 cm (8 in.) 35 cm (13.75 in.) 9 cm (3.5 in.) weighing pan diam. 115 mm (4.5 in.), ph meterrecorder output 0 to 10 mv/ph, 0 to 10 mv/100mv (adjustable), ph range 0-14 phph resolution 0. 01, ph temperature compensation 0 - 100 c, mv accuracy 1 mv, magnetic stirrercapacity 1 litre,stirring paddle q-19 9 x 25 mm,dimensions 150 x 220 x 150 mm, with hotplate, capacity 5 litres, double distillation unit1.5 lph, material borosilicate glass with double stage distillation setup, pyrogen free dimension 650 x 630 x 520mm, flame photometergeneral range ppm, serum range meq,i,urine range meq,i,resolution 0.1 ppm / 0.1 meq,curve at accuracy 2% of fsdisplay 128 x 64 graphical lcd average time in-built in software,flame system lpg & dry oil free air,detector photodiode,aspiration time 3 ml per minute,gas control adjustable with knob,flame failure auto detection,gas cut off automatic,ignition system auto ignition,automiseraxial flow type,dimensions instrument: 365 x 245 x 220 mm approx. (lxbxh),pc interface usb power supply 230 v ac 10%, 50 hz, chromatography chambersize 26x13x26 height 26inch material teak wood, potentiometerrange: 0 to 199.9 mvresolution: 0.1 mvrepeatability: 1mvaccuracy: 1 mv 1 digit input impedance :> 1010 ohms operating temperature : 10 c to 50 c display : 3.5 digit bright red seven segment led display with auto polarity indication power : 230 10% ac ,50hz dimensions : 76*275*170 mm (approx.) weight : 2 kg. (approx.) standard accessories glass electrode : 01 no. reference electrode : 01 no. silver electrode : 01 no. platinum electrode : 01 no. dust cover : 01 no. electrode stand & clamp : 01 no. instruction manual : 01 no., polarimetrytouch screen, no warmup time required when instrument turned on, measuring multiple scales, conductivity meterresolution 0.1 ppm voltage 220 v,ec resolution 0.1 temperature range 0-100 c probe conductivity cell weight 1.5 kg auto cell constant measurement manually cell constant =1k dimension 32/23/18cm display type 3 1/2 digit seven segment led display measurable conductivity range in ppm number of ranges 5 power 230-volt main type of temperature compensation manual no. of calibration points 1 temperature compensation auto cond. range 0-1000 m in 5 range 200m*,2m,20m,200m,1000m phase single phase usage laboratory frequency 50 hz power source electric, handy ph, tds, and conductivity meterph range (-) 2.00 to 16.00,ph accuracy 1%,ph resolution 0.01 ph, orp range 1000 mv,orp accuracy 1%,orp resolution 1 mv,conductivity range,0 to 100 ms/cm,conductivity accuracy 2%,conductivity resolution 1 s,tds accuracy 2%,tds resolution 1 ppm,salt range 0 to 50 ppt,salt accuracy 2%,salt resolution 1 ppm,temp range 0 to 100 deg c,temp accuracy 0.2,temp resolution 0.1 deg c,atc yes,power aaa (1.5v) x 4 batteries, printerconnectivity technology usb, networkprinting technology laser special feature automatic document feeder, fast printing, scanner, copier colour blackmodel name laserjet pro mfp m128fnprinter output monochromemax print speed monochrome 20item weight 11100 gramsprinter media size maximum a4, b5, a6, dl, envelope, ups3kva online ups with 1 year batteries warranty