Get complete information related to latest Ice Flaker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ice Flaker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ice Flaker Tenders.
Tender For supply and installation of miscellaneous items - led notice display board height (min)(mm)-609.6, length(min)(mm)-1920, led pitch (max) (mm)-10, led display board type-single,led colour-red,led type-smd,language-english; regional,unicode support-utf-8,number of display lines]-2,type of displayed infornation-static + scrolling both,viewing angle-horizontal 160 deg or higher & vertical 130 deg or higher,viewing distance (meter)-15,automatic brightness control-yes,led brightness(cd/m2)--4001-5000,pixel pitch (mm)-10,minimum pixel density (dots/meter2)-5000,maintenance-rear,duty cycle-16x 7,life span (hours)-50000,construction-display system,it is consisting of led display board + embedded controller,cabinet-steel/alluminium box duly powder coated,type of installation-outdoor,wi fi connectivity-yes, if yes, type of wi fi connectivity,802.11 b/g/n,usb port-1,gsm connectivity-yes, if yes, cellular data support-4g/lte,input voltage (vac)-110-240,maximum power consumption (watt)-300,weight (kg)-50,on site oem warranty (year)-1, pa- audio sound system with trolly :- system type-1 way,built in uhf receiver-no,number of wireless microphones-2,bluetooth connectivity-avalilable,built in memory (gb)-0,number of channels-1,warranty (years)-1, sanitary napkins vending machine :- type of machine-automatic,operating features-coin operated/free,multiple coins accepted-yes,number of selection options-2,accessibility for free vending utility service-na,type of loading-spiral,maximum storage capacity (nos)(nos)-25-50,material of the outer body-mild steel(ms),built-in charger-no,mode of function-stand alone,operating power source-electronic,battery backup time (hrs)-na,thickness of ss/ms sheet (mm)-1.2,thickness of frp/plastic sheet (mm)-1.2, sanitary napkins incinetator machine with smoke control unit :- stand provided-yes, thickness of thermal insulation material (mm)-40 millimeter, thickness of ms/ss sheet of burning chamber (internal) (mm) (min)-3 millimeter, machine weight(kg)-51-250, thickness of door including insulation (mm)-40 millimeter, flexible emission outlet pipe dia (mm)-76 millimeter, material of housing cabinet (external)-mild steel(crca) sheet, material of burning chamber (internal)-stainless steel sheet of ss-304 grade, material of thermal insulation-high density ceramic board, temperature indicator provided-yes, minimum burning temperature (degree c)-800, burning capacity per day (number of napkins)-1000-1250, burning capacity at a time (number of napkins)-26-50, burning time of full capacity napkins/pads (minutes) (max)-35 minutes, automatic digital controller for time-yes, automatic digital controller for temperature-yes, type of scu (smoke control unit)-top mounted, material of housing of smoke control unit (scu)-mild steel(crca) cabinet, both carbon control and foul odour control chambers for filteration of smoke emission-yes, number of filters in carbon control chamber-one, type of filters in carbon control chamber-ceramic blanket as a filter, number of filters in odour control chamber-one, blower rpm-1800, warranty in years (option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue)-1, wall mounted automatic fire extinguisher:- extinguishing media-powder based (as per is 4308), expellant medium-n2 based, extinguishing agent of powder based fire extinguisher-abc map90, discharge mechanism-automatic, additional requirement (hint: select na if not applicable)-na, cylinder/vessel material-mild steel, valve material-stainless steel, internal coating-epoxy powder coating, external coating-epoxy polyester powder, powder based fire extinguisher capacity (in kg) (hint: select na if extinguishing media is not powder based)-6,7,8&9, clean agent based fire extinguisher capacity (in kg) (hint: select na if extinguishing media is not clean agent)-na, fitted with heat sensor quartzoid bulbs with sprinkler heads-2, class of fire for which fire extinguisher is
Tender For procurement of various laboratory testing equipments to meet requirement of laboratory of geri for the year 2023-2024 - air conditioner 2 tonne capacity, compression testing machine-500 kn - digital pace control compliant with is 14858 and is 516 for testing cement mortar cubes and bricks thermo hygrometer with clock air conditioner 2 tonne capacity, low tempereature water bath chamber size - 300 x 250 x 200 mm and chamber volume 20 litres with temperature accuracy- 0.5 c and temperature range-5 c to 50 c
Tender For purchase of (1) iceflakers (2) air oven (3) fume hood (4) air conditioner and (5) carry out small repair works of laboratories for dept. of chemistry, utkal univ.
Tender For supply of hot air oven size 18" x 18" x 18". triple walled construction outer body made of m.s.powder coated & inner body made of s.s.304. the gap between the two walls filed with mineral wool with 4" insulat ion. heating coil made from special air heater fitted on left & right side of oven. a forced air circulating with motor fitted on top for uniform temperature through out the chamber. temperature controller by microproc essor pid dual digital display controller fitted on top or as per convenience. working temperature 50 to 300 degree centigrade. accuracy +/- 1 degree centigrade. make: bti, remi, tempo, science tech or equivalent. [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras custom bid for services - comprehensive annual maintenance contract of cs12 eakon cold store located at doddanekundi plant acd for a period of 3 years -summary: comprehensive annual maintenance contract includes maintenance, repair/replacement of all the components of the cold stores as follows: a) compressor, condenser unit, evaporator unit, suitable refrigerant, power supply system, control system, all safety features, operator panel, different type of sensors, interconnecting piping including drainage water pipes, cold room panels, coil and drain heaters, doors, lighting, temperature recording panels, and all other electrical, mechanical as well as electronics components of the systems & eurotherm electronic recorder.b) detailed scope of work:1 vendor should take over the cold stores for camc, in as-is-conditions., 2) preventive maintenance (pm) of the units to be carried out every month in consultation with user / maintenance dept, and detailed pm schedule to be drawn up and a copy of the pm carried out (service report) should be forwarded to purchase department duly endorsed by maintenance dept. for the reference and records. this pm should be carried out apart from periodical servicing and attending the breakdown calls. 3) servicing of the units should be carried out once in every three months, within two weeks of commencement of the quarter. this should be carried out preferably on sundays/ holidays. this servicing involves cleaning of condensers, cooling coils, filters (if any) leakage testing & rectification; and any/all other works required to ensure proper functioning of the units. a copy of the service carried out (service report) should be forwarded to purchase dept. duly endorsed by user/ maintenance dept for the reference and records. 4) the firm should monitor the temperature/ attend breakdown / preventive maintenance or any other request from user/ maintenance /quality dept. & monitor the functioning of all the cold stores. the firm should monitor and record the cold store chamber temperature every hour during shift hours and should take signature on recorded values by user, quality dept /maintenance dept. daily. the camc vendor s scope of work will be active for three shifts per day/round the clock, including sundays & holidays, i.e. all days throughout the camc period. 5) the firm should inform all the three departments user/qa/maint. in the event of malfunctioning of the equipment is noticed. they also should ensure safety of the materials stored in the event of failure of the cold stores. 6) the firm should report any abnormality, breakdown, or any bypass made immediately to all the three dept viz user, maintenance and quality dept. the equipment uptime should be greater than 95% without any interruption. 7) the firm should inform to the maintenance department in the case power failure, so that maintenance dept. can arrange for switching on the dg supply. 8) the firm should able to read the temperature in the electronic temperature recorder. 9) the firm should attend any number of breakdown complaints as and when reported by user/ maintenance dept/ quality dept during the contract period. the breakdown complaints should be attended within 8 hrs from the receipt of oral or written complaints and the system should be rectified within a day, except for the major breakdowns. 10) the firm should bring all the tools and tackles necessary including consumables for the repair / servicing. 11) the firm should hand over the cold stores in good working condition after the completion of camc, failing which necessary remedial actions will be taken to recover loses to acd-hal by deducting equivalent amount from the due amount. c) monthly checks: checking and servicing of cold stores.- (a) compressors- condensing units, solenoid valves and all gauges, drier, globe valves and all gauges, hp/lp switches, oil pressure switches ., expansion valve and mixture., refrigerant level and top-up if requir
Tender For anaerobic culture system-1. capacity: suitable for various volumes, typically ranging from small to large-scale cultures.2.. controlled atmosphere:anaerobic environment: ability to maintain oxygen levelsbelow 0.1% using a combination of gas mixtures (e.g., hydrogen, nitrogen) and catalysts (e.g., palladium).gas monitoring: continuous monitoring and control of gas concentrations (e.g., oxygen, hydrogen) within the chamber.3.temperature range: adjustable temperature control, typically ranging from ambient to 45c or higher.4. temperature uniformity: 0.5c or better throughout the chamber to ensure consistent culture conditions.5.humidity control: adjustable humidity levels to maintain optimal growth conditions for anaerobic organisms.6. chamber material:interior: stainless steel construction for durability, easy cleaning, and resistance to corrosion.exterior: powder-coated steel or equivalent for durability and aesthetics.7. access ports:multiple access ports for introducing samples, adding/removing media, and accessing cultures without disrupting the anaerobic environment.8. monitoring and alarm systems:continuous monitoring of temperature, gas levels, and humidity with alarms for deviations from set parameters.9. sterilization:autoclavable components or built-in sterilization cycle to maintain aseptic conditions.10. safety features:pressure relief valve for controlled release of excess gas.emergency backup power supply to maintain anaerobic conditions during power outages.11. user interface:touchscreen or digital interface for easy operation and monitoring of parameters.programmable settings for different culture protocols.12. data logging:? ability to log and store data related to temperature, gas levels, and other parameters for record-keeping and analysis.13. compliance:ce marked and compliant with international standards such as iso 13485 for medical devices or equivalent standards applicable to laboratory equipment.
Tender For supply of vertical, top loading cylindrical autoclave machine for steam and pressure sterilization, steril izer chamber capacity in l (usable volume) 20 - 25 liter, sterilizer chamber type -circular, sterilizer chamb er material double walled ss 304 or higher grade steel, working temperature 121 degree celsius (with inst allation , demonstration and commencement at consignee location) make- htico/sareen surgical/indo surg ical ]