Get complete information related to latest Indication System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Indication System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Indication System Tenders.
Tender For supply of equipment for electrical and electronics engineering department - supply of equipment for electrical and electronics engineering department:, plc with digital & analog i/o moduleinbuilt power supplyadditional voltage sources 12v,5v8 digital inputs with indication led s6 digital outputs with indication led s2 analog inputs with inbuilt ldr potentiometer2 analog outputs with inbuilt dc motor speed controlpower on/off indication led sinbuilt push button:3 inbuilt latch switch:2inbuilt toggle switch:2inbuilt buzzerusb port for programmingconnecting cableswooden enclosure, interfacing of discrete field devices with plc kitsequence of operation:develop ladder logic in plc to execute the following logical relation between the input and output field devices.y= a+b+c+dy= a.b.c.dy=(a+b).(c+d)y= (a.b)+(c.d)interface specifications:plc input interfacing push button(a)limit switch (b)reed switch (c )3wire inductive proximity sensor (d)plc output interfacing buzzer (y)wooden enclosure, plc based water level control systemsequence of operation:develop and execute ladder logic in plc to fill the empty tank with liquid when the start button is pressed. when liquid reaches the high level, turn off the pump motor and turn on the solenoid valve to drain the liquid from tank. when liquid reaches the low level, turn off the solenoid valve and turn on the pump motor for refilling. interface external pilot lamp with plc to indicate the operation of pump motor and solenoid valve.interface specifications:level sensors as input to the plcwater tap as output from the plcwater pump motor control using outputs of the plcwater tank with sump2levels sensor switchespumps for filling tanksolenoid valve to drain water.12v and 24v power supply unitssteel enclosure, plc based forward and reverse control of induction motor kit. sequence of operation:develop and execute ladder logic in plc to control three phase induction motor in forward and reverse direction of rotation. interface external pilot lamp with plc to indicate the direction of rotation. check the output by interfacing plc with three phase cage induction motor.interface specifications:3 phase main contactors.3 phase input, fusesstop, start forward, start reverseforward, reverse indication lamp.proper terminal for 3 hp cage motorsteel enclosure, plc based conveyor system with prewarning siren kit sequence of operation:develop and execute ladder logic in plc using an on delay timer to delay the start of a conveyor. while press the start button, activate the warning siren for pre-set time. after the pre-set time delay the warning siren turns stop button is pressed turns off the conveyor.interface specifications:conveyor setupplc input interface start, stop push switches.plc output interfacing siren output to give alarm.plc output interfacing conveyor belt with geared dc motor drivessteel enclosure, plc based counting of moving objects on a conveyor kit sequence of operation:develop and execute ladder logic in plc for counting the object moving in the conveyor. interface manual start and stop push button to operate the conveyor motor and proximity sensor detect the object. interface buzzer to give beep sound while sensor is detecting the product. when the pre-set value of count has reached turn off the conveyor automatically.plc based counting of moving objects on two conveyors kit. sequence of operation:a manufacturing plant is arranged with two feeder conveyors for transferring the objects into the plant. develop and execute ladder logic using math instruction in plc to get the total number of objects transferred by two conveyors into the plant. when the total object count has reached pre-set count value, turns on buzzer to give beep sound for 1 second and turns off the conveyors.interface specifications:conveyor setupplc input interfacing proximity sensor with each conveyor to sense the object.plc input interfacing start push switch and stop push switchesplc output buzzer output to give ala
Tender For comprehensive type annual maintenance contract for sli system (safe load indicationsystem) of 140 ton bd crane based at ambala cantt (umb) and bathinda (bti) for the period of three years
Tender For supply, installation & commissioning of ohe high volatge presence, absence detection and indicationsystem as per technical specification attached
Tender For supply of procurement of power contractors - item name off delay timer 0.1sec to 10hr, item name control contactor tca3dn40md, item name power contactor 25a , item name power contactor 9a lcid093-a60, item name power contactor 50a p, item name control relay-24v ac, item name pwr contactor for ec panel, item name indicating lamp(led)-red, item name indicating lamp-led-green, es type hrc fuse 32a, item name es type hrc fuse 63a , item name switch disconnector fuse10-32a, item name off delay timer 0.1sec to 10hr, item name control contactor tca3dn40md, item name power contactor 25a , item name power contactor 9a lcid093-a60, item name power contactor 50a p, item name control relay-24v ac, item name pwr contactor for ec panel, item name indicating lamp(led)-red, item name indicating lamp-led-green, es type hrc fuse 32a, item name es type hrc fuse 63a , item name switch disconnector fuse10-32a
Tender For providing and fitting fixing of electrical accessories, spare of panel board of different water supply schemes at different locations under dws sub-division, belonia during the year 2025-26. - providing and fitting fixing of spare contact kits without coil (l & t make) for auto star delta starter., b) ml-2 type., c) ml-1.5 type., providing and fitting fixing of standard operating coil (l & t make) for auto star delta starter., b) ml-2 type., c) ml-1.5 type., supplying and fitting fixing of 4 pole ac control contactor (nhd series) suitable for bch made starter (standard coil voltages are 24, 110, 220/240 & 380/415 v, ac hz)., supplying and fitting fixing of 3 pole power contractor (type-mnx) suitable for 10 hp to 25 hp motor.mnx-25 (for l&t made starter), supplying and fitting fixing of pneumatic timer pn type delay relay-electro pneumatic) suitable for delay of time upto 30 sec. (bch made)., supplying and fitting fixing electronic timer type st-100 (l & t make) suitable for 240/300/415v, 50 hz having ranges for 3-30 secs/12-120 secs., supplying and fitting fixing of single phase preventer on delay 2 sec off delay 7 sec 65 vac asymmetry., providing & supplying of kit-kat rewireable porcelain fuse (cut-out) carrier & base of havells made (delux quality)., a) 63 amps/415 volt, b) 100 amps/415 volt, supplying and fitting fixing of 3 pole power contractor (type-ml) suitable for 10 hp to 25 hp motor.type ml-2 (for l&t make starter), supplying and fitting fixing of thermal timer type gt-200 (l & t make) suitable for 230/250v, 360v, 400/440v, 50 hz for 5-18 secs., supplying and fitting fixing of thermal overload relays mn2 type (directly operated& direct mounting on mnx 9-40 contactor) of l & t made. (suitable for ml/mnx type)., a) for relay range 9-15 a., b) for relay range 14-23 a., c) for relay range 20-33 a., supplying and fitting fixing of thermal overload relays (directly operated& direct mounting on ml-2/3 contactor) having relay range 9-14a/13-21a of l & t made. (suitable for ml-2/ml-3 type)., supplying and fitting fixing of citation-m overload relays (direct mounting with built in single phase protection) having relay range of bch made., a) for relay range 8.9-13.5 a., b) for relay range 13.2-30.00 a/17.4-24.00 a., c) for relay range 22.00-30.00 a., providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) gamair wood/ plywood pannel board for fitting fixing of electrical items, in/c 2 nos ms angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the engineer-in-charge., providing and fitting fixing 3 phase indicating lamp fiited with panel board with three different colour lamps with batten holder complete as per specification and direction of the engineer-in-charge., providing and fitting fixing heavy duty box type (resin filled) power factor correction capacitor l & t make etc. complete as per specification and direction of the engineer-in-charge.i) 5-15 kvar 440 v, supplying isi marked/ taparia make tools for water supply scheme., i) sly wrench, ii) screw driver, iii. pipe wrench, iv. plier, v. hexo frame with blade, providing and fitting fixing of moving iron type, range 0-500 v, 96 mm x 96 mm size ac volt meter ( l & t / ae make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the engineer-in-charge., providing and fitting fixing of moving iron type, range 0-100/0-200 amp, 96 mm x 96 mm size ac amps meter direct reading type ( l & t / ae make) with selector switch and ct coil as a electrical instrument of the pannel board as per specification and direction of the engineerin-charge., providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for din fuses), tripl
Tender For supply of for breaker 400 11 02 06b , fixed contact breaker 300a 11 06 04a , fixed contact breaker 400a 11 06 04b , fixed contact for isolator 200a 05 01 03 , glass fuse with holder bogf , ct for ol lat1005 , current transformer for ol lat3005 , current transformer for ol lat4005 , isolator micro switch assembly 05 05 00 , earth leakage relay 50 750ma with time lag with cbct elm7lat s 80m , glass fuse with holder bogfh , cover bolts 000110a , cover bolts 000110h , indicating lamps lab9acb , overload assembly breaker 30a 100 a 11 01 00a , incoiming gland g1 , shunt trip coils 11 09 03 , push button actuator for el test boes2 , core balance transformer cbt80m , power cable for 400 a for breaker chamber ic and og set iccb4 , fault imposing relay without base booen3r , power cable for 300 a for breaker chamber ic and og set iccb3 , core balance transformer cbt70m , terminal bushing with insulator dmc incoiming 8 mm x 25 mm t5 , no volt coil assly under voltage assly with moulding 11 04 00a , current transformer for ammeter 120 300 5 5 , thermal overload relay 12 00 21 , potential transformer ds1 , on delay timer 135 30 on , aux. contactor 220v ac boca2dn1229 , indiciating lamp with pcb mouting lab9 geb , on off rev isolator 300a k4r , resistance 139 geb , current trasfoemr for o l 15va 120 200 5 15 , on off isolator 400 a k4s , on off rev isolator 200a k3r , isolator 3 p on off k3 , vcb aux rotary switch boarc , vcb shunt trip coil 50 05 00 , potential tranformer 3 point 3 kv htptl1 , earth leakage 50 750ma and 750ma 2a dual setting with time lag with cbct elm7dlat s 80m , control relay 110v 135 110 , indicating lamp lab9 tsu ht , vcb closing coil 50 10 00 , neutral monitoring relay with resitance nrmr , voltmeter 600 for tsu -lt 130 v 0 600 so tlt , core balance transformer cbt90m , hrc ht pt fuse boabwna , aux contactor mcra022a7 , vacuum interrupter bevoo53 , ht bushing htta 3 point 3 , reset push button contact element no nc boes1 , earth leakage 50 750ma and 750ma 2a dual setting with time lag elm7dlat s , hv bushing httc , multicore bushing mcb9 , current trasformer bo400 5ctr , test off run selector switch bosrp137b , aux transformer single phase ptfx , auxiliary contactor with coil boca2dn1229 , current transfomer 60 5 15va 120 60 5 15 , current transfomer 120 100 5 15 , ht bushing with stud 3 point 3 kv htta 3 3 , ht hrc pt fuse bossabwna , indicator panel lab9 3 3kv , miniature circuit breaker bosp6 , overload relay magnatic olr3 , resistance 06 05 08 , vacuum contactor 3 3 kv bevoo61 3 3 , current transfomer coil 110 v dc indigenous bevoo49 , copper terminals with dmc bushing t5 , no actuator boes2 , nc actuator boes3 , isolator handle h9 , hrc fuse 16 amp 138 16 , hrc fuse 63 amp 138 63 , earth leakage 50 750ma with time lag elm7lat s
Tender For supply, installation & commissioning of ohe high volatge presence, absence detection and indicationsystem as per technical specification attached