Get complete information related to latest Induction Coil Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Induction Coil Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Induction Coil Tenders.
Tender For bid to ras tender for supply of supply of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure ii-a , supply of cassette ac four way capacity 3 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure ii-a , supply of cassette ac four way capacity 4 tr rating inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure ii-a , supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4tr cassette acorsplit ac unit refer annexureii-a , providing flexible pvc duct hose covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte ac units refer anexure ii-a , providingcpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureii-a , providing cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexureii-a , supply of rain proof outdoor duty as per ip-66 electrical control panel with incommer 4 pole mccb 100 amp digital voltmeter digital ammeter indication lamps refer annexureii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 4 sqmm refer annexureii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 6 sqmm refer annexureii-a , supply of following size lt power cable with copper conductor laying of the same in by eic 4core - 25 sqmm refer annexure-ii-a , supply of following size lt power cable with copper conductor as directed by eic 4core - 16 sqmm refer annexure-ii-a , supply of copper cable of size 4core - 2point5 sqmm for communication refer annexure-ii-a , supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness refer annexure-ii-a , supply of perforated hot dipped galvanised iron cable tray of size 300 mm width x 50 mm depth x 1point6 mm thickness refer annexure-ii-a , installation testing and commissioning of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotaryorscroll compressor aircooled refer annexure-ii-b , installationtesting and commissioning of cassette ac four way capacity 3 tr minimum 3 star rating inverter type refer annexure-ii-b , installation testing and commissioning of cassette ac four way capacity 4 tr inverter type rotary or scroll compressor units refer annexure-ii-b , erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4tr cassette acorsplit ac unit refer annexure-ii-b , laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable refer annexure-ii-b , laying of cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexure-ii-b , laying of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-ii-b , erection testing and commissioning of rain proof outdoor duty as per ip-66 electrical control panel annexure-ii-b , laying of following size lt power cable with copper conductor xlpeorpvc insulation pvc inner sheathed armoured extruded pvc oas directed by eic 4 core - 4 sqmm refer annexure-ii-b , laying of following size lt power cable with copper conductor xlpeorpvc insulation as directed by eic 4 core - 6 sqmm refer annexure-ii-b , laying of following size lt power cable with copper conductor as directed by eic 4 core - 25 sqmm refer annexure-ii-b , laying of following size lt power cable with copper conductor xlpeorpvcas directed by eic 4 core - 16 sqmm refer annexure-ii-b , laying of copper cable of size 4 core - 2point5 sqmm for communication refer annexure-ii-b , installing of perforated hot dipped galvanised iron cable tray
Tender For supply of cabin air conditioning spares for hemms equipments - 1600036686_refrigerant r134a 1kg , 1600007847_valve p n vl0101 , 1600036680_ferrule 3 8 o ring flare o ring adtr 3 8 fa0112 fa0115 , 1600036681_ferrule 1 2 o ring flare o ring adtr 1 2 fa0113 fa0116 , 1600036682_ferrule 5 8 o ring flare o ring adtr 5 8 fa0114 fa0117 , 1600036679_compressor fitting assy cpn108 alternate part no cpr105 , 1600010793_dryer reciver w pres sw p n dr0101 , 1600036685_compressor oil sp 10 250ml cp0101 , 1600008723_condenser unit bd355 p n cr4101 , 1600031702_orifice tube drier p n ev0105a , 1600224148_blower motor housing complete ev0103 , 1600224149_blower motor rotor ev0104 , 1600008730_condenser condensor fan 24v p n cr4103 , 1600036678_coupler drier evr115 , 1600036683_blower motor ev010 , 1600007200_switch p n ev0107 , 1600007199_valve p n ev0105 , 1600009340_fuse glass 10a p n ev0110 , 1600009341_fuse glass 15a p n ev0111 , 1600035971_air filter assembly p n ev1003 , 1600011792_thermostat p n ev0106 , 1600036688_evaporator assy complete bd355 ev2001 , 1600019371_ac compressor rd 5 10725 op , 1600035969_motr blowr asembly 24v p n rd 3 14448 1p , 1600224138_switch rotary 3 speed rd 5 10934 0p , 1600224139_knob rotary control rd 5 8812 0p , 1600224140_switch rocker black rd 8967 0p , 1600224141_evaporator assembly rd 2 3413 0p , 1600224142_condenser rd 4 5378 0p , 1600224143_evaporator cooling coil rd 2 1909 0p , 1600224144_evaporator cooling coil rd 2 2047 0p , 1600224145_90 degrees female o ring connector rd 5 6978 0p , 1600224146_90 degrees male o ring connector rd 5 6944 0p , 1600224147_90 degrees male o ring connector rd 5 6955 0p , 1600007567_o ring p n rd 5 6840 0p , 1600009095_valve expansion p n rd56868op , 1600035965_evaporator coolng coil p n rd 2 1370 0p , 1600035966_condensor coil p n rd 4 3945 0p , 1600007584_o ring p n rd 5 9987 0p , 1600009113_fan motor assy 24v p n rd 5 8703 3p , 1600035967_swich mode off on on p n rd 5 7183 0p , 1600035968_swich rocker fan p n rd 5 7181 0p , 1600017559_filter recirculation p n rd 5 12203 0p , 1600007553_switch p n rd 5 0071 op , 1600010873_resistor p n rd53647op , 1600035970_recirculating filter p n rd 3 6162 1p , 1600006347_switch high pressure p no rd 5 4833 op
Tender For operation and maintenance of e&m services in parliament library building, new delhi (s.h.: replacement of cooling / heating coil of ahus alongwith drain tray & eliminator)
Tender For bid to ras custom bid for services - sludge and insulation removal of tank 120 t 05a-1.1. sludge removal: the approximate sludge / oil inside the tank is to a tune of 2800 cu.m. a) agency needs to assess the quantity of sludge through site visit prior to quoting. b) the quantity provided is the best estimate and may vary. please note that additional payments will not be made for excess sludge removed, and no deductions will occur in the event of lesser sludge quantities with respect to the sludge quantity mentioned above. c) approach path from south main road (i.e., from south of the common dyke of tanks 120-t05a,05b,06,06b) up to south west of tank 120-t-05a shall be provided by hpcl. d) however, approaches / access requirement around the circumference of the tank to facilitate sludge removal and insulation removal, the preparation of the same shall be in within agency scope. e) agency has to collect sludge using sludge bins at outside of clean out door. if required, excavation for placing sludge bins matching the elevation of the clean out door has to be done by agency. sludge bins to be mobilized by the agency. f) disconnecting existing electrical connection, temporary dismantling of platform, ladder or any other structural, fire protection system like cooling water connection, foam connection, removal of existing instruments and any other removable or fixed attachment required for isolating the tank is in agency scope. g) removal of existing instruments, accessories etc. provided in existing tanks and preserve the same in designated area as per instruction of job engineer is in agency scope. h) removal of sludge from tank, transfer of sludge to designated area, unloading / dumping of sludge in designated area (sludge lagoons) inside refinery, complete cleaning of the tank after sludge removal, making the tank hydrocarbon free and suitable for further hot work is in agency s scope. contractor to submit sludge removal procedure to hpcl. i) opening / cutting shell course (coupon cutting) for creating access for entry of excavator / jcb inside the tank for carrying out sludge removal. barricading inside tank in coupon cutting area for hot work preparation for coupon cutting is in agency scope. any other preparatory jobs as per jsa for carrying out hot work for coupon cutting and vehicle entry inside tank is in agency scope. j) existing steam coil: agency shall dismantle existing steam coil including supports from the existing bottom plate. k) sacony & propeller mixers: agency shall dismantle existing sacony mixers & propeller mixers. l) wherever existing internals are removed like sacony mixers / eductors / propeller mixers / jet mixers / heating coils etc., care shall be taken not to damage the bottom plate during removal of supports. m) all necessary work related to isolation of tanks to carry out sludge removal including removal of piping spools including tagging and dumping in the designated yard, blinding of nozzles, proper barricading required shall be in contractor s scope and shall be carried out as per instructions of job engineer. n) transportation and dumping of all scrap materials generated during modification works, after cleaning, in the designated scrap yard as per instruction of the job engineer. o) arranging of all equipment, tools & tackles, machinery, lifting equipment, mobile crane, fork lift, crane, jcb, tipper, trailer, scaffolding etc. is in the scope of the agency.-msme exemption - no | startup exemption - no
Tender For corrigendum : procurement of m/s michell make thrust pad and spares for bearing of cepfor ntpc vindhyachal - set of lower thrust pad (rh) , set of lower thrust pad with rtd hole , set of upper thrust pad lh , cooler (cooling coil)
Tender For corrigendum : supply of cooling coil, for package ac dpw 1322s , cooling coil, for package ac dpw 1322r2 , condenser for 15tr scroll ac unit