Tender For supply, erection , testing & commissioning of outdoor type transformer of capacity 33kv/0.415 kv, 100 kva, copper winding with all safety device , ee level 2, other standard all accessories and specification as per cege/grc's specification no: ser/elec/gs/description/trans/4/rev-0/oct 2023, attached annexure-a, is:1180 part 1 (2014) with latest amendment, submission of type test report of above rating of transformer and gad/gtp along with offer is mandatory.
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical and suture items - anti a blood grouping serum ip(anti a monoclonal serum) [225], anti b blood grouping serum ip(anti b mono clonal serum) [226], anti d(rh) blood grouping serum ip/anti d blood grouping serum ip [227], vdrl antigen (with +ve and -ve control) / rpr slide kit :- specification for rpr _rapid plasma regain) slide test for detection of regain antibodies in syphilis1. rapid plasma reagin test kit having non- treponemal cardiolipin antigen coated carbon particles used in the detection of regain antibodies in serum / plasma of suspected cases of syphilis by the flocculation reaction.2. the kit should be meant for qualitative and semi quantitative detection of regain antiboidies against the non-treponemal cardiolipin antigen.3. sensitivity & specificity should be 95% or more.4. positive & negative control serum should be provided with the kit for at least 10% of the tests in each kit.5. the kit should have shelf life of minimum 12 months or more at the time of delivery of consignment. the kit should be stored at 2 c - 8 c.6. adequate literature detailing the principle, components, methodologies, validity criteria. bio-safety, performance characteristics, storage conditions, limitation of assay, manufacture and expiry dates and methods of disposal should be provided with each kit.7. the test should be free from possible interferences with potentially cross reactive sera.8. all the test kits should be provided with necessary / required disposable accessories in sufficient quantity.9. the imported kit should have approval of the statutory authority in its country of origin . the imported kits should have been registered and licensed in india by the cdsco. (central drugs standard control organization), double blood bags with sagm (350ml)general specifications annexure- xvi and specification in annexure-xxiii, laproscopic knotless pga -pcl bidirectional taper point surgical suture self fixation device with autolock mechanism made up of pga -pcl bidirectional taper point 17 mm & 32cm, curved cutter stapler 40 mm linear cutter simultaneous cutting and stapling, aortic punch 4.5 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, aortic punch 3.6 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue,conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, biopsy gun with compatible co-axial needle 14g x 11cm to 20cm programmable automatic should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved., programmable automatic biopsy gun with compatible co-axial needle size 18gx11cm or above should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved. (size 18gx11cm or above), programmable automatic biopsy gun with compatible co-axial needle size 18gx15cm or above should have 20mm sample notch and thin wall cannula for larger core and
Tender For supply of outdoor type 11kv/0.415kv, 250 kva transformer with energy efficiency level 2 (or above) including all accessories as per type test report of same rating & capacity transformer from oem m andatory along with supply offer of transformer. specifications as per cege/grc's specification no. ser/elec/gs/description/trans/4/rev-0/oct 2023 annexure. all safety device conforming to latest is sp ecification. [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras supply of edge ai device 40 tera operations per second , iot network lpwan based , iot cloud platform , soil moisture temperature and electrical conductivity sensor based on lpwan , soil npk sensor based on lpwan , soil ph sensor based on lpwan , air temperature and humidity sensor based on lpwan , leaf wetness sensor based on lpwan , weather station based on lpwan , pump controller based on lpwan , agricultural iot test bed for lab trainers
Tender For corrigendum : supply of spares parts - zone module card generator new co2 system , manifold check valve size 3 by 4 inch w p 60 bar test pr 90bar generator new co2 system , mater elect or pneumatic valve with solenoid valve pr 60bar generaror new co2 system , pneumatic operated valve slave for generator new co2 system , online weighing device with limit switch model szl wl k 24vdc 1 by 2 inch npt f for generator new co2 system , manifold or piping pressure switch min o by p 5 bar w by p 60bar contact rating 10a 500v ac dc electrical connection 3 by 4 inch et cable gland generartor new co2 system , bleeder valve size 3 by 8 bsp o by p 3kg per square cm seat ptfe valve rod ss steel spring generaror new co2 system , pressure relife device 165 to 170kg per square square cm inlet 3by 8 inch bsp outlet 3 by 8inch bsp dia 25mm length112 point 5mm generator new co2 system , n2 pilot cylinder quick release valve k85 13 to 83 , pressure gauge with switch contact and solenoid valve for quick relaese valve generator new co2 system
Tender For corrigendum : supply of consumabe, regents and diagnostic kits - anti a 1gm, anti b 1gm, anti d 1gm, anti d blend (1gm+1gg), anti d (1gg), anti ab 1gm, anti a 1 lectin, anti h lectin, bovine albumin 22%, ahg (polyspecific), anti k monoclonal (1g m), anti c monoclonal (1g m), anti c monoclonal (1g m), anti e monoclonal (1g m), anti e monoclonal (1g m), blood bags (single) 350 ml, blood bags (single) 100 ml, blood bag double, 350ml, blood bag double, 450ml, blood bag triple, 350ml, blood bag triple, 450ml, transfer bag 300ml without anticoagulant, quadruple blood bags with sagm, 450ml, hiv kit rapid, hcv kit rapid, hbsag kit rapid, rapid tp (treponema pallidum/syphillis) test, malaria test kit rapid, hydrogen peoxide11%, plain tubes, edta tubes (vacutainer), band aid, thermal paper (thermographs) 4", glass slides 75mmx26mmx1.5mm, glass tubes 12mm x 75mm, glass beakers 200ml, glass beakers 500ml, autoclave tape, lancets, copper suphate anhydrous, glycerol 10%, distilled water, normal saline, microtips for micropippetes, disposable pipettes 1ml, disposable pipettes 5ml, low ionic strength salt solution (liss) , wagers for sterile connection device, platelet bag with lab side leucofilter, platelet additive solution, ecoshield, rubber balls, torniquets, disposable glasses for drining water