Get complete information related to latest Intake Gate Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Intake Gate Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Intake Gate Repair Tenders.
Tender For supply of c s rising spindle sluice valve dn 200 , c s rising spindle sluice valve dn100 , gun metal gate valve 1 inch , butterfly valve model 12 80 nb , butterfly valve model 12 size 50 nb , cl body diaphragm valve 150nb , cl body diaphragm valve 100nb , c point s non rising spindal dn 150 6 inch , gun metal gate valve 2 inch , c point i point foot valve swing type nb 200
Tender For corrigendum : supply of foot valves for water works purpose as per is 4038 (latest) (q3) , swing check type reflux valves for water works purposes (single door pattern) (v2) as per is 5312 (part1) (q3) , sluice valve for water works purposes (50 to 1200 mm size) (v2) as per is 14846 (q3) , copper alloy gate valve for waterworks purpose as per is 778 (q3)
Tender For corrigendum : procurement of spares of fly ash system for unit no. 1 to 4 ph i and ii, sgtps, mppgcl, birsinghpur. - diffuser mounting plenum assembly for nuva diffuser feeder 12x10, seat for nuva diffuser feeder 12x10, disc for nuva feeder diffuser feeder 12x10, inside lever for 12x10 nuva diffuser feeder, shaft with key for nuva diffuser feeder 12x10, 25 nb diaphragm operated pressure valve 2 way model no. kpl/25d of eastern pneumatics, 40 nb diaphragm operated pressure valve 2 way model no. kpl/40d of eastern pneumatics, diaphragm assembly set with spring for 25 nb dia diaphragm valve , diaphragm assembly set with spring for 40 nb dia diaphragm valve , pneumatic cylinder size 6" bore x 7" stroke assembly, body fluidizer(fluidizing pad) 4 wide 48 long with imported ss element & ms bolt for nuva diffuser feeder, adjustable compression spring for disc of nuva feeder diffuser feeder 12x10, spares for 18 swing gate v/v of transfer hopper, shaft with key for transfer hopper, seat & disc for 18 transfer hopper valve assembly , pivot ball assembly of transfer hopper, outside lever , inside lever, supporting (reinforcement) disc, gun metal nrv 25 mm, body casing for 18 swing gate v/v, pneumatic cylinder size 4" bore x 6-3/8" stroke assembly, bearing housing (support plate) with oil seal for 18 swing gate v/v of transfer hopper, s.s. stud bolt 12x50 with double nut, s.s. stud bolt 12x75 with double nut, spares for 2.5, 2 way vent valve, two way vent valve complete assembly, valve seat for two way vent valve, valve disc for two way vent valve, shaft with key for 2 way vent valve, 2.5 vent v/v inside lever, roll pin for 2 way vent valve., pneumatic cylinder size 2.5" bore x 4" stroke assembly, body casing, flow regulator (size-1/4) for pneumatic cylinder (2.5x4")
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For supply of 1 inch hp ball valve part no.h080000003 , hose assy f by discharge gate cylinder part no.h060000158 , hpcs ball valve 1.5 inch part no.mah010b12ag1 , accumulator part no.mbh013a142ag , dc valve for fcg fast operation part no.mah46yukonv , dc valve 3 position with special adopter part no.h070000126 , pilot operated check valve part no.h090000017 , uhmw guide bar for discharge gate part no.m010000641 , mill duty hydraulic cylinder for flow co part no.h050000029 , auto pressure release module part no.h030000069 , h.d. pipe clamp 1 inch nb part no.h140000009 , h.d. pipe clamp 1.5 inch nb part no.h140000011 , mill duty hydraulic cylinder for swing c part no.h050000012 , flanged bearing with 4 bolt mounting part no.m040000113 , pressure relief valve part no.h100000020 , plumber block for fcg part no.m040000131 , main hydraulic pump part no.mah008a28c2f , flange brg for flow control gate part no.mam001b3000a , unloading relief valve assy part no.r4v1053310ai , check valve for urv part no.mah025urvcvd , 3 by 4 inch hose 1.2 mtr long with end fitting part no.h060000085 , inch 1 inch inch hp hose 4sh series 2 mtr long with part no.h060000031 , dc valve with d3d01pilot 2position part no.mah021g0dh2a