Web Analytics Made Easy - StatCounter

Integrated Management System Tenders

Get complete information related to latest Integrated Management System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Integrated Management System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Integrated Management System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :43853095 Due date: 25 Feb, 202625 Feb, 2026 7.57 Lacs
Tender For providing of hiring of agency for iso certification service - ns 1 integrated management system ims certification of latest version of iso 9001 2015 qms iso 14001 2015 ems iso 45001 2018 ohsms iso 50001 2018 enms and 5s of coaching depot ash gkp gtnr and roh depo..,hiring of agency for iso certification service - ns 1 first surveillance audit after 12 months of issued ims and 5s certification of coaching depot ash gkp gtnr and roh depot gd; consultancy services for implementation, training, documentation, inter..,hiring of agency for iso certification service - ns 1 second surveillance audit after 12 months of issued ims and 5s certification of coaching depot ash gkp gtnr and roh depot gd; consultancy services for implementation, training, documentation, inte..,hiring of agency for iso certification service - ns 2 training documentation implementation and audit accreditation and issue of 5s certification of ljn bnz mur gd bst kld and gkp railway stations in ljn division of ner; consultancy services for impl..,hiring of ag

CTN :43800000 Due date: 10 Feb, 202610 Feb, 2026 NA
Tender For providing of custom bid for services - procurement of service for mcu software programming 02 mpc and mcu and mpc 4 repair and software programming as per sotr boq

Central Government/Public Sector

CTN :43760102 Due date: 23 Feb, 202623 Feb, 2026 NA
Tender For certification of integrated management system (ims) on iso 9001:2015, iso 14001:2015, iso 45001:2018 and iso 50001:2018, implementation and certification of "5s" technique, and certification of green company rating system (greenco) at electrical loco shed, bhusawal, for a period of three (03) years.

CTN :43680628 Due date: 12 Feb, 202612 Feb, 2026 86.50 Lacs
Tender For supply of 3 dof drone stability test jig along with proprietary softwares , 2 dof drone stability test jig along with proprietary softwares , bldc motor thrust bench along with proprietary softwares , drone sensor testing equipment , flight controller assembly programming station , battery charging and testing staion , battery repair station , drone service tools , soldering and rework station , esd workbenches , cnc router machine , 5-inch fpv drone kit , 7-inch fpv drone kit , 10inch fpv drone kit , fixed wing ac kit vtol configuration , logistics drone kit , nano drone , fpv googles , remote controller , spares , battery charger , carbon fiber sheets 500mm x 25o mm x 5mm , carbon fiber sheets 500mm x 250 mm x 2mm , installation and training

CTN :43728208 Due date: 21 Feb, 202621 Feb, 2026 NA
Tender For supply of 3 tesla mri conditional dual chamber (dddr) with feature for fluid level in lungs assessment with rate drop response and matching electrodes (atrial lead 52 cms screwing & ventricle lead 58 cms screw/tined) , pli and magnet & fluro cover. weight around 20 gms and volume around 10 cc. device longevity more than 10 yrs. must have atrial & ventricular capture management. must have atrial fibrillation management algorithms overdrive pacing, atrial rate stabalization. must have antitachycardia pacing algorithms for terminating atrial arrhythmia. must have rate drop response - must have algorithm which have been proved by large scale clinical trials to combat in precipitous drop in rate. must have dual zone rate response. must have facility for remote monitoring, active in india. must have feature which monitors the fluid level build up in the lungs such as optivol. lead monitor and polarity switch. dual zone rate response for programming different rates for activities of daily living. must be 3 tesla mri conditional pacemaker for full body scan. the oem must have registered office with service personnel available round the clock. warranty: all pacemakers should be covered by life time warranty (providing pacing therapy for the duration of patient's life time).[ai(2025-26) , item code no.s-62237, sl no.2012. ]

CTN :43723876 Due date: 13 Feb, 202613 Feb, 2026 5.89 Lacs
Tender For triennial contract of consultancy services for is/iso ems (14001-2015) and is/iso ohsms (45001-2018) under integrated management system (ims) for ktps.

State Government

CTN :41524390 Due date: 18 Feb, 202618 Feb, 2026 3.70 Crore
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou
 Loading, Please wait...

Connect us via What's Up