Get complete information related to latest Invertor Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Invertor Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Invertor Scrap Tenders.
Tender For electrical work in connection with providing 125 nos. 1.5 ton capacity window type ac unit on hiring basis over ahmedabad division and hiring of inverter type split ac unit 1.5 ton capacity for tte rest room-ahmedabad for the period of five years.
Tender For providing of facility management services - lumpsum based - cctv set library almira inverter set zembo cooler supply installation and commissioning of all products; cctv set library almira inverter set zembo cooler supply installation and commissioning of a..
Tender For corrigendum : sitc of ductable and split acs - 3.0 or 3.5 tr single circuit air cooled ductable split ac unit , supply of 1.5 tr single circuit air cooled ductable split ac unit , supply of 2.0 tr single circuit standalone floor standing tower type air cooled split ac unit , supply of 3 star rating 1.5 tr inverter type wall mounting type split air conditioner , supply of 5 star rating 1.5 tr inverter type wall mounting type split air conditioner , itc of 3 or 3.5tr ductable split ac unit , itc of 2 tr tower split ac unit , itc of 1.5 tr capacity split a.c unit , providing fabricating and fixing m s stand a. 40 x 40 x 5 mm ms angle iron , b. 40 x 5 mm ms flat strip , supplying and fixing of powder coated prefabricated ms frame stand , sitc of of following nominal sizes of hard drawn copper refrigerant piping a. 6.4 mm dia od soft drawn with tube thickness 1.2 mm with 19 mm thick insulation , b. 9.5 mm dia od hard drawn with tube thickness 1.2 mm with 19 mm thick insulation , c. 12.7 mm dia. od hard drawn with tube thickness 1.2 mm with 19 mm thick insulation , d. 15.56 mm dia od soft drawn with tube thickness 1.2 mm with 19 mm thick insulation , e. 22.2 mm dia od hard drawn with tube thickness 1.2 mm with 19 mm thick insulation , providing and fixing following size dia frls, hms upvc pipe a. 40mm dia , b. 25 mm dia. , supply and fixing of control cum transmission wiring a. 5c x 4 sq.mm pvc insulated copper conductor cable , b. 4c x 1.5 sq.mm pvc insulated copper conductor cable , sf of pvc insulated pvc sheathed copper conductor armoured cable of 4c x 6 sq.mm , supplying and fixing fp sheet steel enclosure on surface or recess along with 25 or 32 a 415 v c curve fp mcb , supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 230 v c curve dp mcb , sitc of gss sheet metal rectangular ducting a. thickness 0.63mm sheet , b. thickness 0.8mm sheet , providing and fixing supply air grills of powder coated aluminum , supplying and installing following size of galvanised iron cable tray a. 100 mm width x 50 mm depth x 1.6 mm thickness , b. 150 mm width x 50 mm depth x 1.6 mm thickness
Tender For bid to ras tender for supply of supply of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure ii-a , supply of cassette ac four way capacity 3 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure ii-a , supply of cassette ac four way capacity 4 tr rating inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure ii-a , supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4tr cassette acorsplit ac unit refer annexureii-a , providing flexible pvc duct hose covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte ac units refer anexure ii-a , providingcpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureii-a , providing cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexureii-a , supply of rain proof outdoor duty as per ip-66 electrical control panel with incommer 4 pole mccb 100 amp digital voltmeter digital ammeter indication lamps refer annexureii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 4 sqmm refer annexureii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 6 sqmm refer annexureii-a , supply of following size lt power cable with copper conductor laying of the same in by eic 4core - 25 sqmm refer annexure-ii-a , supply of following size lt power cable with copper conductor as directed by eic 4core - 16 sqmm refer annexure-ii-a , supply of copper cable of size 4core - 2point5 sqmm for communication refer annexure-ii-a , supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness refer annexure-ii-a , supply of perforated hot dipped galvanised iron cable tray of size 300 mm width x 50 mm depth x 1point6 mm thickness refer annexure-ii-a , installation testing and commissioning of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotaryorscroll compressor aircooled refer annexure-ii-b , installationtesting and commissioning of cassette ac four way capacity 3 tr minimum 3 star rating inverter type refer annexure-ii-b , installation testing and commissioning of cassette ac four way capacity 4 tr inverter type rotary or scroll compressor units refer annexure-ii-b , erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4tr cassette acorsplit ac unit refer annexure-ii-b , laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable refer annexure-ii-b , laying of cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexure-ii-b , laying of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-ii-b , erection testing and commissioning of rain proof outdoor duty as per ip-66 electrical control panel annexure-ii-b , laying of following size lt power cable with copper conductor xlpeorpvc insulation pvc inner sheathed armoured extruded pvc oas directed by eic 4 core - 4 sqmm refer annexure-ii-b , laying of following size lt power cable with copper conductor xlpeorpvc insulation as directed by eic 4 core - 6 sqmm refer annexure-ii-b , laying of following size lt power cable with copper conductor as directed by eic 4 core - 25 sqmm refer annexure-ii-b , laying of following size lt power cable with copper conductor xlpeorpvcas directed by eic 4 core - 16 sqmm refer annexure-ii-b , laying of copper cable of size 4 core - 2point5 sqmm for communication refer annexure-ii-b , installing of perforated hot dipped galvanised iron cable tray