Tender For bid to ras providing of hiring of agency for isocertification service - iso 27001 - information security management system (isms), iso 13485 qms for medical devices; consulting, initial audit; workshop on awareness of isocertification for employees, guidance for documenta..,hiring of agency for isocertification service - iso 27001 - information security management system (isms), iso 13485 qms for medical devices; accreditation for certificate; obtaining certificate from nabcb accredited body,hiring of agency for isocertification service - iso 27001 - information security management system (isms), iso 13485 qms for medical devices; surveillance audit; conduct surveillance audit
Tender For request proposal for supplying various equipment, chemicals, standard reference microbial cultures, glasswares/ plasticwares and general items in 9 numbers of district level water testing laboratories of jharkhand a-dumka zone - refrigerator- ( 265 litre approx., double door ),make & model: branded ( is standard), analytical balance-( 4digit), weighing capacity of 220g, externally calibrated by nabl accredited lab/agency with calibration certificate, make & model: branded) ( is standard), ph meter-(measuring range ph0.0-14.0), make & model: branded ( is standard), hot plate with magnetic stirrer-(power: 2000 watt approx., operating volts: 230a15 volts a/c), stirring capacity: 50-1500 rpm, capacity of stirrer: 2 litre, plate size: 18.4x18.4 cm(approx.), make & model: branded, bacteriological incubator-digital construction -double walled construction outer body made of mild steel powder coated & inner body made of stainless steel, insulation : glass woll insulation between two walls. inner size : 18" x 18" x 24", rating watts 750, no. of shelves 3, capacity 120 ltrs, temp range- 5 c - 60 c accuracy +/- 0.5 c, temp controlled by : controlled by pid micro process controller with dual display. selves : with g.i. wire mesh selves, door : 2 door inner acrylic door to view sample & outer metal door with air circulation motor with blower for uniform temperature throughout chamber. heater : special nichrome heater designed for long life & saving of power consuption. thermometer type : electronic with digital display. make & model : branded ( is standard), laminar air flow chamber(biosafety cabinet)-external dimensions (lxwxh) in inches and mm:40 x34.25 x56.7, (1020 x870x 1440) work area dimensions: 34.45 x24 x22.52 (857x610x572) material of construction: galvanised iron sheet with epoxy polyester thermosetting powder coating of 80 microns, 1.5mm thickness/stainless steel grade 304,1.2mm for ss modelsbody finish: glossy off white colour for gi powder coated table top: 1.2mm ss 304 sheet of matt finish pressed on 25mm solid nuwud board side glass: 6mm float glass encased in stainless steel channels front door: frameless gas spring loaded swinging type polycarbonate 6mm thickness wheels and levelling lugs: pu solid wheels with plated brackets and metallic powder coated design: front bottom loading pre-filters or completer work area with stainless steel including hepa grill cleanliness class: iso standard 14644-1- class 5 stages of filtration: a.pre-filters= 10 with an efficiency of 90 % washable hdpe media in frp pu coated frame b.mini pleat hepa filter encased aluminium frame with an efficiency of 99.995% motor blower assembly: variable speed mtor mounted on pu coated frp blowers with aluminium powder coated impellers velocity: 100 fpm at 6 from face of the filter noise level: less than 60db at 1 meter from the face of the equipmenthepa filter grill: stainless steel grills duly perforated and polished electrical specifications: a. switches and speed controller: microprocessor controlled feather touch switch panel b. fluorescent lighting: 18 watt. c. chokes for lighting: 18 watt d. ultraviolet lighting: 1.5 feet length g15t8, 15 watt power consumption: 250 watts lighting: greater than 800 lux power supply: 230v,50hz power supply, single phase 5 amperes power cord accessories: gas burner, gas/vacuum cock ( is standard), autoclave -vertical autoclave size 14" dia x 22" ht, rating in watts 3000, capacity of 52 ltrs complete s.s with foot lifting arrangement used for sterilization under saturated steam pressure at 15psi with double walled units with inner chamber made of thick stainless steel and outer chamber made of s.s.lid is made of thick gauge stainless steel with pressure gauge steam release valve, and safety valves. with foot lifting arrangement. with s.s. basketaccessories:1. digital temperature indicator cum controller with timer -1 no.2. water level cut off-1no.3. pressure cut off switch-1no. ( is stan
Tender For purchase of equipment, configuration design multichannel electrochemical workstation containing a minimum of 2 channels with impedance system should have a minimum of two potentiostat/galvanostat modules in single cabinet to operate independently and simultaneously1. general description chassis: multichannel single chassis a minimum of two channels should have electrochemical impedance spectroscopy (eis) measurements2. specification for channels cell connection: 4 (we, s, ce and re) channels required: a minimum of 2 channels must be equipped with eis facility compliance voltage: 20 v or better per channel applied voltage: 10 v or better per channel maximum output current: 400 ma or better current ranges: 10 na to 100 ma or better resolution of applied/measured potential: 3 v or better voltage accuracy: 0.1 % of full-scale range or 3 v or better measured current resolution: 800 fa on lowest current range or better frequency range: 10 hz to 1 mhz or better impedance accuracy/resolution: 1%& 1 at 1hz or 0.003% gain bandwidth range of amplifier: 1 mhz or better bandwidth of electrometer: 1mhz or better input bias current: 20 pa or better possibility to upgrade to high current up to 10 a or better using booster provision to connect external devices or use optional accessories internal resistance determination acquisition rate: 1000,000 samples/second3. complete software with the following specification software should be capable of supporting a wide variety of electrochemical techniques especially mentioned below.4. electrochemical impedance two channel should have eis measurement facility with frequency range 10 hz to 1 mhz or better5. desktop computer pc i5 (or higher), 8gb ram, 1tb hdd, 22" led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. should be procured from india6. optional accessories7. general terms and conditionswarranty: 3 years manufacturer s warranty certificate. vendor should be an authorized provider of sophisticated high-precision potentiostat/galvanostat systems for past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. please provide cost split up of each accessory. mention the cost of optional accessories separately.
Tender For corrigendum : to carry out stage-1 audit, stage-2 audit, issuance /renewal of iso certificate 9001:2015, iso 14001:2015 and iso 45001:2018 and carry out surveillance audit-1 & surveillance audit -2 for gmdcsvarious mines & project in gujarat state
Tender For corrigendum : supply of chemicals and crms - bod standard solution traceable to nist or any other national or international standard. calibration certificate indicating uncertainty should be provided at the time of supply , chromium standard solution traceable to nist or any other national or international standard. calibration certificate indicating uncertainty should be provided at the time of supply , copper ii sulphate 0.1m 0.1n standardized solution traceable to nist , phenol standard solution traceable to nist or any other national or international standard. calibration certificate indicating uncertainty should be provided at the time of supply , potassium chloride solution nominal 0.147 ms per cm certified reference material for the measurement of electrolytic conductivity traceable to ptb and nist , silver sulphate 99.5 percentage ar acs , sodium carbonate volumetric standard traceable to nist or any other national or international standard. calibration certificate indicating uncertainty should be provided at the time of supply , tds standard solution traceable to nist or any other national or international standard. calibration certificate indicating uncertainty should be provided at the time of supply , uv vis standard 1a potassium dichromate solution 600 mg per l for the absorbance at 430 nm , uv vis standard 2 sodium nitrite solution for stray light testing , uv vis standard 3 sodium iodide solution for stray light testing , uv vis standard 4 potassium chloride solution for stray light testing , uv vis standard 5 toluene solution in n-hexane for testing of the resolution power , alkalinity crm should be supplied with certificate traceable to nist , bod crm 200 mg per l should be supplied with certificate traceable to nist , copper ii sulphate crm copper ii sulphate 0.1 m 0.1 n standardized solution traceable to nist , iodide crm traceable to nist , ph 7 crm buffer solution di sodium hydrogen phosphate potassium dihydrogen phosphate traceable to srm from nist and ptb ph 7.00 25 degree c , phenol crm 500 myuv g per ml in methanol should be supplied with certificate traceable to nist , potassium dichromate crm potassium dichromate volumetric standard secondary reference material for redox titration traceable to nist , residual free chlorine crm rfc 0.5 to 3.0 mg per l, trc 0.5 to 3.0 mg per l, crm produced and certified in accordance with iso 17034 and iso iec 17025 , sulfide crm, 1000 500 myuv g per ml, crm produced and certified in accordance with iso 17034 and iso iec 17025 , tds crm, 1000 mg per l, should be supplied with certificate traceable to nist , total suspended solids crm, should be supplied with certificate traceable to nist
Tender For supply of flash back arrestor (dry type) for regulator end of oxygen lines to prevent flash backs in oxy fu el system conforming to en 730/iso 5175-1/is 11006 standards with flame arrestor (fa) and non return valve ( nrv) and thermal cut off valve (tv) working pressure:15 bar. end connections g 3/8 rh to en 560/iso 3253 sta ndards. make: messer (dgn oxy) or esab or gce (fr-34 r oxy) or weldstar or witt only . note:1) offers of oems or their authorized dealers enclosing valid authorized dealership certificate only will be considered. 2) th e suppliers shall send test certificate from govt. authorized test house. in case of international brand, the test c ertificate from reputed institute like bam, germany is mandatory. 3) the suppliers should have equipments for testing of flash back arrestors and calibration.(product catalogue to be attached during quote for reference) [ warranty period: 12 months after the date of delivery ]
Tender For safety chain to be as per is 3076:1984 grade t (8) or latest. the specifications as issued b y rdso are to be adhered to in their entirety except that the nominal size (thickness) of the short link cha in is to be 13 mm (?0.5mm) to 14 mm (?0.5 mm) and long links at ends with ring/suitable locking arrange ment for padlocking is to be of the length of 4.5 meters. further, the length of the short link chains is to b e kept at 50 mm and width at 35 mm. these are electrically welded round steel short link chains, fully he at treated and tested and comply with the general conditions of acceptance of iso 1834 or latest. the siz es range from 5 to 45 mm. (based on user requirement). the steel used shall be produced by the open he arth or electric process, or by an oxygen blow process. it shall be steel alloy. marking shall be done as per is 3076:1984 grade t(8) or latest. supplier shall supply a certificate of test and examination carried out b y the government owned lab or nabl approved labs with every supply of chain. there should be name of the chain maker, grade of material, size of chain, identification marking, proof force applied to the whole chain. no. of test sample taken, breaking force of each sample, total ultimate elongation at fracture, duri ng manufacture the heat treated chain shall be subjected to force of 60% of the minimum breaking force. ]
Tender For instruments equipments ( part-3 of 3 ) - micro suture tying forceps with platform cvd. 15cm / 6" (0.3mm) ce four digit with notified body / usfda (registered). iso 9001:2015, iso 13485:2016 and iso 7153-1-2016, iso 14001-2015, iso 7376-2020 and whogmp certified company. surgical instrument made by steel grade aisi 410 and 420, (nabl accredited certified laboratory) test report from should be submitted with tender document/at the time of sample.laser marking along with catalogue code should be on the instruments, 1 unit, 1604, mikulicz (liver retractor) retractor for deep surgery 26cm x 10 1/4" (90 x 35mm) ce four digit with notified body / usfda (registered). iso 9001:2015, iso 13485:2016 and iso 7153-1-2016, iso 14001-2015, iso 7376-2020 and whogmp certified company. surgical instrument made by steel grade aisi 410 and 420, (nabl accredited certified laboratory) test report from should be submitted with tender document/at the time of sample.laser marking along with catalogue code should be on the instruments, 1 unit, 1608, miniature forceps, curved upwards to left, with 1 mm cupped jaws, sheath conically reinforced from distal to proximal end, with cleaning connector, working length 23 cm, usfda and ce approved, 1 unit, 1612, miniature straight forward telescope 0, diameter 1.1 mm, working length 10 cm, niti, semiflexible, with scale, autoclavable, working channel diameter 0.45 mm, irrigation channel diameter 0.25 mm, length 140 cm, remote eyepiece, fiber optic light transmission incorporated for use with: stone extractor , micro burr for salivary stones , guide wire 7, laser probe, usfda and ce approved, 1 unit, 1616, mollison (4:4 teeth sharp) self retaining retractor 15cm / 6" ce four digit with notified body / usfda (registered). iso 9001:2015, iso 13485:2016 and iso 7153-1-2016, iso 14001-2015, iso 7376-2020 and whogmp certified company. surgical instrument made by steel grade aisi 410 and 420, (nabl accredited certified laboratory) test report from should be submitted with tender document/at the time of sample.laser marking along with catalogue code should be on the instruments, 1 unit, 1620, morris (with ring handle) retractor 22cm / 8 1/2" (3 1/2") ce four digit with notified body / usfda (registered). iso 9001:2015, iso 13485:2016 and iso 7153-1-2016, iso 14001-2015, iso 7376-2020 and whogmp certified company. surgical instrument made by steel grade aisi 410 and 420, (nabl accredited certified laboratory) test report from should be submitted with tender document/at the time of sample.laser marking along with catalogue code should be on the instruments, 1 unit, 1624, mosquito artery 5" straig ce four digit with notified body / usfda (registered)/ iso 13485 (registered with nabcb under medical devices quality management system.)manufacturer should have cdsco accredited notified body certificate should be necessarily provided with the tender. manufacturer should have pollution certificate ( necessarily provided with the tender.) all instruments should be manufacture by iso 9001:2015, whogmp certified company. surgical instrument made by steel grade aisi 410 and 420, (nabl accredited certified laboratory) test report from should be submitted with tender document/at the time of sample. laser marking along with catalogue code should be on the instruments instruments and sterilization containers should be of same parent companyinstruments should be reflection free for better vision and long lasting due to high surface hardness, light weight and user friendly., 1 unit, 1628, mustoid retractor 2*2 , ce four digit with notified body / usfda (registered)/ iso 13485 (registered with nabcb under medical devices quality management system.)manufacturer should have cdsco accredited notified body certificate should be necessarily provided with the tender. manufacturer should have pollution certificate ( necessarily provided with the tender.) all instruments should be manufacture by iso 9001:2015, whogmp certified company. surgical in
Tender For providing of hiring of agency for isocertification service - iso 3834; initial audit, re-certification audit, surveillance audit, issue of certificate; recertification audit issue of certificate surveillance audits