Get complete information related to latest Isolator Pad Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Isolator Pad Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Isolator Pad Tenders.
Tender For supply of expansion type terminal connector to suit 50 dia aluminium tubular bus-bar to terminal pad of 25 kv isolator/ct/cb (ri no. /part no. 11061, 11062, 11063) with fasteners, as per rdso specification ti/ spc/ohe/fitting/0130-10/13-rev-1 & drawing no. eti/psi/p/11060, rev.e or latest. make/brand - core ap proved vendors only. (list attached) [ warranty period: 30 months after the date of delivery ]
Tender For supply of material for various grid stations, line material for various line t and p , hardware items - conductor, power cables, power clamps and connectors for acsr /aaac conductor, al. alloy as per is: 617 of 1975 pg clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) and those stipulated in section-iii of this tender document suitable for acsr zebra conductor having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of zebra conductor. likely makes: rul, zi, honeywell, burma, pee, equivalent etc/ as per departmental sample provided, al. alloy as per is: 617 of 1975 pg clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) and those stipulated in section-iii of this tender document suitable for acsr moose conductor having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of moose conductor. likely makes: rul, zi, honeywell, burma, pee, equivalent etc/ as per departmental sample provided, al. alloy as per is: 617 of 1975 t-clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) and those stipulated in section-iii of this tender document suitable for acsr zebra conductor having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of zebra conductor. likely makes: rul, zi, honeywell, burma, pee, equivalent etc/ as per departmental sample provided, al. alloy as per is: 617 of 1975 t-clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) and those stipulated in section-iii of this tender document suitable for acsr moose conductor having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of moose conductor. likely makes: rul, zi, honeywell, burma, pee, equivalent etc/ as per departmental sample provided, al. alloy as per is: 617 of 1975, bi-mettalic ct clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) and those stipulated in section-iii of this tender document suitable for acsr zebra conductor having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of zebra/moose conductor with ct terminals suitable for 220/132kv/33kv cts of makes/ae mumbai, sct gaziabad, bhel, vidhyut control system andhra, mehru bhiwadi/ laxshmi engg bhopal, jyoti etc / as per departmental sample provided, al. alloy as per is: 617 of 1975, bi-mettalic ct clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) and those stipulated in section-iii of this tender document suitable for acsr moose conductor having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of zebra/moose conductor with ct terminals suitable for 220/132kv/33kv cts of makes/ae mumbai, sct gaziabad, bhel, vidhyut control system andhra, mehru bhiwadi/ laxshmi engg bhopal, jyoti etc / as per departmental sample provided, al. alloy as per is: 617 of 1975, bi-mettalic isolatorpad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) and those stipulated in section-iii of this tender document suitable for acsr zebra conductor having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of zebra/moose conductor with pad terminals suitable for 220/132kv /33kv isolators of east land, elpro, hivelm calcutta, s&s,gr power, skipper, bimco,andhra mech. industries etc likely makes: rul, zi, honeywell, burma, pee, equivalent etc/ as per departmental sample provided, al. alloy as per is: 617 of 1975, bi-mettalic isolatorpad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) and those stipulated in section-iii of this tender document suitable for acsr moose conductor having bolts hot dip galvanized nuts and washers electro galvanized a
Tender For annual preventive / breakdown maintenance of equipments at 220/132/33kv substations under 220kv oandm division rishikesh - 220 kv switchyardtightening of 220 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 160 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 220 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work, overhauling of mechanism of 220 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 220 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 220 kv take-off assembly/ moving head assembly/rotary head devive etc. (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer, topping up of sf-6 gas in 220 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 220 kv switchyard., 132 kv switchyardtightening of 132 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 132 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work., overhauling of mechanism 132 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete., replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 132 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 132 kv take-off assembly/ moving head assembly/rotary head devive etc (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer., topping up of sf-6 gas in 132 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 132 kv switchyard., 33kv switchyard:tightening of 33 kv bay equipments (cb, line isolator, ct including all connectors of droppers/runner/jumpers), cleaning of 40 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 33 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles, assistance in testing work., overhauling of mechanism 33 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/ runner/ dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 33 kv terminal connector/clamp/jaw/blade etc. and tighgtening of related equipment (including replacement of minor con