Get complete information related to latest Isolator Spare Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Isolator Spare Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Isolator Spare Tenders.
Tender For supply of set of rotary switches consisting of two items 1). change over switch in packet design, 300 amp 250- 440v ac/dc 4 pole 4 p osition 90 degree operation, with capstan handle to switch on cat no. hd3049dtr or equivalent in abb or siemens or l&t -01 no. 2). bat tery isolator switch in packet design, 300 amp 250- 440v ac/dc 4 position 90 degree operation, with capstan handle to switch on cat no . hd3035l12td or equivalent in abb or siemens or l&t -01 no. [ warranty period: 30 months after the date of delivery ]
Tender For supply, installation, testing and commissioning of various electric item on annual rate contract - supply of din rail mounting contactor and accessories confirming to iec 61095 with following description and configuration in existing distribution board / sheet including making connections, testing etc. as required.oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr modular contactor 40a - 3no, supply of wiring for sub mains isi marked (is:694) 1100 volts grade pvc insulated flat twin core sheathed solid aluminium conductor as required. for additional technical parameters of product / work refer annexure a attached with this bsr4.0 sq.mm, 6.0 sq.mm, 10.0 sq.mm, supply of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16-20 mperes including making connection, programming conforming to iec 0730-1 and 60730-2-7 etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer exure "a" attached with this bsr.one day & week reserve (analog type ), one day & week reserve (digital type ), supply of 240/415 v ac mcb with positive isolation of 10 ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating including making onnections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr. single pole mcb (with b/c curve tripping characteristics) 0.5 a to 5 a rating, 6 a to 32 a rating, 40 a rating, 63 a rating, providing & fixing of 240/415 v isolator isi marked is:13947- iii/conforming to iec 60947-3, suitable for ac22a utilization category, 4kv impulse withstand voltage, true contact indication, red colour dolly / lever shall have single mould covering overall poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. ip 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr. double pole isolator 30 a / 40 a rating, 63 a rating, triple pole isolator 40 a rating, 63 a rating, sitc of single stage, water cooled, high speed (2880 rpm), horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal - t/c vs t/c, thrust bearing shall be of carbon + s.s.the stator body of single phase pump shall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition (ced) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034-2-1: 2007, iec 60034-30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submit nabl / cpri / erda accrediated lab type test certificate before executio
Tender For procurement of electrical material for day to day maintenance of ei and fans of zonal building under karol bagh zone -, supply of 1.5 sq. mm isi marked, fr pvc insulated, single core copper conductor cable , supply of 2.5 sq. mm isi marked, fr pvc insulated, single core copper conductor cable , supply of 4.0 sq. mm isi marked, fr pvc insulated, single core copper conductor cable , supply of 6.0 sq. mm isi marked, fr pvc insulated, single core copper conductor cable , supply of 10 sq. mm isi marked, fr pvc insulated, single core copper conductor cable , supply of 32/0.20 mm (1.0 sqmm) twin circular, frls pvc sheathed workshop flexible copper cable , supply of modular bell push, isi marked , supply of 3 pole mccb, 100a, 16ka , supply of 25 amp modular spmcb , supply of 6 amps. to 32 amps. ratings , sp mcb, "c" curve, 10 ka breaking capacity , supply of 6 amps. to 32 amps. ratings , spn mcb, "c" curve, 10 ka breaking capacity , procurement of electrical material for day to day maintenance , supply of 6 amps. to 32 amps. ratings , dp mcb, "c" curve, 10 ka breaking capacity , supply of 6 amps. to 32 amps. ratings , tp mcb, "c" curve, 10 ka breaking capacity , supply of 6 amps. to 32 amps. ratings , tpn mcb, "c" curve, 10 ka breaking capacity , supply of 40 amp 2 pole isolator , supply of 63 amp 2 pole isolator , supply of 40 amp 4 pole isolator , supply of 63 amp 4 pole isolator , supply of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cmm/w) minimum 6.85, air delivery minimum 215 cmm, 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan fresh air type complete with shutter blades etc. as required. , supply of led tube type luminaire 20 watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient leds with the following:(a) total system wattage 20 watt +/- 5%(b )luminous efficacy lumens/watt >=95 (c)power factor >=0.95 , sitc of wall mounted fan 400mm sweep rated voltage 220-230 ac rated frequency 50hz speed 1280-1350 rpm with desired color
Tender For repairing of electrical assets in te chhoulas, bts chhoulas, dadri (old), falanda bangar, thora (gr noida). - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed in medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required.a) group a, wiring for ckt wiring with 3 x 1.5 sqmm pvc ins cu cond single core in pvc conduit etc., wiring for with 3 x 4 sqmm pvc ins cu cond single core in pvc conduit etc., wiring ckt/power wiring 6 x 4 sqmm pvc ins cu cond single core in pvc conduit etc., supply & fixing metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front i/c providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps piano type switch connection, painting etc. as required., s/f of switch 5a piano type,connection etc, s/f of socket 3 pin 5a piano type,connection etc, s/f cu wire 2 core 1.5 sqmm etc, sitc of 20 watt 1200 mm led tubelight fitting omplete with all accessories etc. as required. (m/s bajaj/ surya,/ philips or similar superior make)-, sitc of ceiling fans 1200 mm sweep 2star rating complete with all accessories etc. as required. (m/s havells- es-neo/es-plus or similar superior make), s/f of regulator piano type,connection etc, supplying and fixing of dp sheet steel enclosure in recess or surface with 25/32 amp, 240 volt, c curve dp mcb i/c connection etc as reqd. -- for ac, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of upto 35 sq. mm on wall/ surface/ in loop as required., pdg.& fixing 6 swg gi wire on surface or in recess for loop earthing alongwith the existing surface/recessed / cable etc.as required., s/f 4 sqmm frls pvc insulated cu conductor single core cable ( for neutral earthing ), supplying and making end termination with brass compression gland and aluminium lugs for 4x16 sqmm/3.5 x 25 sq.mm /35 sqmm size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required., sitc of switch fuse unit rewireable type 63a 415 volt on wall, connection etc as reqd (make - hpl/ havells- / l&t or similar superior make )-, sitc of 4 pole 63a 415 v on load change over switch with side/front handle operation in sheet steel enclousers on wall, connection etc ( make - hpl/ havells- euro load/ l&t or similar superior make )-, supply & fixing 4 way, single door ,sheet steel, tpn mcb distribution board, 415/240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (but without mcb/ rccb/isolator)., supply & fixing of following rating mcbs in the existing mcb db complete with connection, testing & commissioning etc. as required. (i) 5-32 amp sp mcb c series, (b) 4pole63a 415v isolator, tp mcb 25a-- for power plant, painting of lt panel (outer side) with good quality of paint, removing old paint & dust, cleaning, etc etc, earthing with gi pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/ coke and salt as reqd (for dg neutral -02 nos, body earth -02 nos, for neutral power supply co -01 no total- 05 nos), providing & fixing of 25mm x 5 mm g.i strip on surface or in recess for connections etc. as reqd.
Tender For repairing of electrical assets in dhoom manikpur, badoki, janpath, bishada, kalonda (gr noida). - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed in medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required.a) group a, wiring for ckt wiring with 3x1.5 sqmm pvc ins cu cond single core in pvc conduit etc., wiring for with 3x4 sqmm pvc ins cu cond single core in pvc conduit etc., wiring ckt/power wiring 6x4 sqmm pvc ins cu cond single core in pvc conduit etc., supply & fixing metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front i/c providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps piano type switch connection, painting etc. as required., s/f of switch 5a piano type,connection etc, s/f of socket 3 pin 5a piano type,connection etc, s/f cu wire 2 core 1.5 sqmm etc, sitc of 20 watt 1200 mm led tubelight fitting omplete with all accessories etc. as required. (m/s bajaj/ surya,/ philips or similar superior make)-, sitc of ceiling fans 1200 mm sweep 2star rating complete with all accessories etc. as required. (m/s havells- es-neo/es-plus or similar superior make), s/f of regulator piano type,connection etc, supplying and fixing of dp sheet steel enclosure in recess or surface with 25/32 amp, 240 volt, c curve dp mcb i/c connection etc as reqd. -- for ac, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of upto 35 sq. mm on wall/ surface/ in loop as required., pdg.& fixing 6 swg gi wire on surface or in recess for loop earthing alongwith the existing surface/recessed / cable etc.as required., s/f 4 sqmm frls pvc insulated cu conductor single core cable ( for neutral earthing ), supplying and making end termination with brass compression gland and aluminium lugs for 4x16 sqmm/3.5 x 25 sq.mm /35 sqmm size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required., sitc of switch fuse unit rewireable type 63a 415 volt on wall, connection etc as reqd( make - hpl/ havells- / l&t or similar superior make )-, sitc of 4 pole 63a 415 v on load change over switch with side/front handle operation in sheet steel enclousers on wall, connection etc ( make - hpl/ havells- euro load/ l&t or similar superior make )-, supply & fixing 4 way, single door ,sheet steel, tpn mcb distribution board, 415/240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (but without mcb/ rccb/isolator)., supply & fixing of following rating mcbs in the existing mcb db complete with connection, testing & commissioning etc. as required. (i) 5-32 amp sp mcb c series, (b) 4pole63a 415v isolator, tp mcb 25a-- for power plant
Tender For annual tender 2025-26 supply of electrical goods in perungulam town panchayat - 4 feet flourescent tube light, 40w copper choke, 40w tube light starter, 36w / 40w tubelight electronic choke, tube light side lock holder, insluation gum tape roll - isi, 1/18 vir copper wire [1/44] [90mtr], 3/20 cts copper wire [3/36] [90mtr], 7/20 cts copper wire [7/34] [90mtr], 7/16 cts copper wire [7/67] [90mtr], 19/16 cts copper wire [19/51] [90mtr], 1.5 sq.mm 3 core copper cable, 2.5 sq.mm 3 core copper cable, 4 sq.mm 3 core copper cable, 6 sq.mm 3 core copper cable, 10 sq.mm 3 core copper cable, 16 sq.mm 3 core copper cable, 36w 4pin lamp holder, 36w lamp clip, 24w t5 holder, led fitting top protection glass - street light, led fitting top protection glass - flood light, 20 / 25 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 32 / 40 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 6amps to 32 amps sp mcb, 40amps 2pole isolator, 63amps 4pole isolator, 32a d.p switch, mcb box, fuse unit 16 amps 240v, fuse unit 32 amps 415v, fuse unit 63 amps 415v, fuse unit 100 amps 415v (heavy duty), fuse unit 200 amps 415v (heavy duty), fuse unit 300 amps 415v (heavy duty), fuse unit 400 amps 415v (heavy duty), fuse unit 500 amps 415v (heavy duty), main switches spn 32 amps, main switches tpn 32 amps, main switches tpn 63 amps, main switches tpn 100 amps, main switches tpn 315 amps, 63a 4pmc changeover switch, 100a 4pmc changeover switch, automatic on/off street light timer switch with 24hrs 7 days programable digital timer clock, 40 amps 4 pole contactor with coil, mcb switch and connector fully wired with all accessories, street light meter/main box with wooden board, main switch, fuse carrier fully wired with all accessories, electronic 7 days 24 hrs programable ditial timer clock, 63 amps 4 pole contact with coil, 220v - 250v contactor coil, power capacitor, 9w led bulb, 15w led bulb, 30w led lamp, 24w t5 power saver lamp, 2x24w t5 power saver choke, 36w 4 pin non retrofit type cfl power saver lamp, 36w 4 pin non retrofit type cfl power saver choke, 20w high bright led 4 feet light, 20w led power saver street light fitting, 25w led power saver street light fitting, 30w led power saver street light fitting, 36w led power saver street light fitting, 50w led power saver street light fitting, 60w led power saver street light fitting, 80w led power saver street light fitting, 120w led power saver street light fitting, 150w led power saver street light fitting, 100w led power saver flood light fittings, 150w led power saver flood light fittings, 200w led power saver flood light fittings, 40w all-in-one solar led street light fittings, 60w all-in-one solar led street light fittings, 80w all-in-one solar led street light fittings, 18w to 25w led chip board, 30w to 36w led chip board, 45w to 60w led chip board, 72w to 90w led chip board, 120w to 200w led chip board, 18w to 25w led heavy duty electronic driver, 30w to 36w led heavy duty electronic driver, 45w to 60w led heavy duty electronic driver, 72w to 90w led heavy duty electronic driver, 120w to 200w led heavy duty electronic driver, 10 kv surge protector, 48` ceiling fan with all accessories, d.o.l motor starter up-to 10 hp, 10metre hot dip galvanised octogonal pole with round ring arm and 4nos of strong 5feet anchor bolts, templates, and nuts etc.. complete set, 1 hp to 10hp single phase control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 5 hp to 7.5hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 10 hp to 25hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., service charges automatic on/off street light
Tender For corrigendum : supply of 415v, utilization category ac23a, 630a local isolator cabinet in sheet steel enclosure complete with 630a, 3 pole load break switch. 2. shall be with side operated handle, padlocking facility, prebreak micro switch having 1no+1nc contact. 3. micro switch contacts shall be wired to 4 sq mm tb for external termination. 4. provision of padlock system having sufficient space to lock the isolator at off position by minimum two agencies at a time. 5. complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. detachable bottom gland plate for entry of cables from bottom. 7. front door shall be hinged and inter-locked with the isolator in 'on' position. the front door should have a minimum 3 mm thickness perspex/triplex window for observation of position of contacts. 8. isolator should confirm to iec 60364 standard. 9. the dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. isolator cabinet should be provided with rain canopy. 11. any isolator parts should not be made of aluminium/aluminium alloy. 12. isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as ip-55. 13. provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. all hardware used in isolator cabinet shall be corrosion resistant. 15. minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. cabinet should be painted with alkaline resistant epoxy paint. 17. isolator cabinet shall have provision for earthing at two separate and distinct points. 18. each isolator cabinet should be supplied with panel keys., push button station specification: 1. pbs made of 2mm sheet steel enclosure with rain canopy, protection: ip-65. 2. 01 no. of green colour start pb with 1no+1nc contacts, 01 no. of red colour stop pb with 1no+1nc contacts, 01 no.of increase pb with 1no+1nc contacts <(>&<)> 01 no.of decrease pb with 1no+1nc contacts. one emergency stop push button with 1no+1nc contacts (push to lock type) shall be provided. size of each push button is of 22.5mm diameter. inscription plate for all push buttons. 3. pb shall be wired with 2.5 sq.mm. copper wire to 40 nos. serially numbered terminal blocks (tb) of elmex make having tb-5-6, 7-8, 11-12, 13-14 <(>&<)> 17-18 shorting link. 4. two nos. of cut out of size 72x72 mm for ammeter and rpm meter shall be provided. 5. 'on','off' <(>&<)> 'trip' indication led lamps in red, green <(>&<)> amber colour respectively with inscription plate to be provided. 6. all push buttons, elements, led lamps <(>&<)> cutout for ammeter <(>&<)> rpm meter shall be on the hinged door of the pb station. 7. pb station shall be weather proof, neoprene rubber gasket suitable for outdoor application. 8. 2nos. of earthing studs to be provided. 9. left side hinged door shall be provided with flexible braided copper earthing. 10. pbs shall have 04 nos. of corrosion free bracket suitable to fix on vertical surface. 11. detachable gland plate to be provided. 12. the push button shall be painted with one coat of red oxide primer <(>&<)> two coats of zinc chromate primer and finally finished with stoving enamel grey paint. 13. the push button station shall be generally in line of enclosed drawing (fig-2). 14. party to submit the drawing along with the offer for technical scrutiny.