Tender For tender for supply of a non distructive test on steel members i dpt test , ii ut ultrasonic thickness gauge , iii sagging defection test total station , iv to check verticality of column , 1 b non distructive test on concrete members visual inspection as per specified in specification of documents , site testing charges concrete 2 upv testas per specified in specification of documents , 3 rebound hammer test schmidt s rebound hammer test for determining the concrete compressive test ref is 13311 part 2 , 4 half cell potential accordance in with astm c876 half cell potential to assess the probability of corrosion of reinforcement sac code 998346 , 5 carbonation in accordance with bs 1881 201 1986 clause 2 22 carbonation test to measure extent of carbonation from the concrete surface sac code 998346 , 6 profomete scan test on rcc members to assesss covers spacing of bars including approximate diameter bar , 7 core test core cutting and compression test for rcc structure in accordance with js 516 on rcc members. 70mm core cutting in reinforcement concrete core filling by specialized epoxy material micro concreate with bond coat , 8 preparing detail report per specified in specification of documents
Tender For work of inspection of boiler water wall tubes and corrosion mapping by remote field electromagnetic testing (rfet) during coh of unit- 3 in 210mw, bhusawal tps
Tender For corrigendum : tender for supply of attending ea set located upto 25km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 25km to 50km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 50km to 100km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 100km to 200km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , carry out b check servicing of 7.5kva to 15kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 15kva to 32.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 32.5kva to 62.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool n tackle etc as reqd , carry out b check servicing of above 62.5kva to 125kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 160 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 200 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 250 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , providing and fixing of 12mm dia wire braided pvc pipe for diesel supply and return lines in existing ea set incl. testing , commissioning etc as reqd , providing and fixing of benjo and benjo bolt with washer and scew on pipe clamps at both ends for existing ea set incl. testing , commissioning etc as reqd , providing and topping up of corrosion inhibitor coolant in radiator of existing ea set incl. testing , commissioning etc. as reqd. , providing and topping up of 15w40 grade lubricating oil of recommended make in existing ea set incl. testing , commissioning etc. as reqd. , providing and fixing of 2 no. 50 sqmm copper conductor flexible cable leads each of 1 mtr length incl. lugs and battery terminals at both ends for starting battery of existing ea set as reqd. , providing and fixing of battery terminal socket set for dg starting battery incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve suitable for 7.5 kva to 32.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve with solenoid switch suitable for 45 kva to 125 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 7.5 kva to 62.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 75 kva to 250 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of ignition switch or push button for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of engine start key switch incl. testing , commissioning etc. as reqd. , providing and fixing of oil pressure guage for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of water temperature guage for ea se
Tender For corrigendum : tender for supply of attending ea set located upto 25km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 25km to 50km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 50km to 100km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 100km to 200km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , carry out b check servicing of 7.5kva to 15kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 15kva to 32.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 32.5kva to 62.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool n tackle etc as reqd , carry out b check servicing of above 62.5kva to 125kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 160 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 200 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 250 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , providing and fixing of 12mm dia wire braided pvc pipe for diesel supply and return lines in existing ea set incl. testing , commissioning etc as reqd , providing and fixing of benjo and benjo bolt with washer and scew on pipe clamps at both ends for existing ea set incl. testing , commissioning etc as reqd , providing and topping up of corrosion inhibitor coolant in radiator of existing ea set incl. testing , commissioning etc. as reqd. , providing and topping up of 15w40 grade lubricating oil of recommended make in existing ea set incl. testing , commissioning etc. as reqd. , providing and fixing of 2 no. 50 sqmm copper conductor flexible cable leads each of 1 mtr length incl. lugs and battery terminals at both ends for starting battery of existing ea set as reqd. , providing and fixing of battery terminal socket set for dg starting battery incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve suitable for 7.5 kva to 32.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve with solenoid switch suitable for 45 kva to 125 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 7.5 kva to 62.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 75 kva to 250 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of ignition switch or push button for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of engine start key switch incl. testing , commissioning etc. as reqd. , providing and fixing of oil pressure guage for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of water temperature guage for ea se
Tender For supply, installation, testing & commissioning of celling mounted inverter type 4 way cassette air conditioner of capacity 4 tr of rated cooling capacity 45720 btu(min), r 410 a or latest refrigerant with 100% copper condenser outdoor unit fan motor should be propeller bldc type, bee star rating-5,operating voltage 220 vac, 50hz.high head drain pump should be provided for proper drainage of condensed dew dr ops generated from evaporation. outdoor unit fins should be corrosion resistance heat exchanger protectiv e coat for the saline climate including cord less remote and all allied accessories. make lg or hitachi or mi tsubishi or panasonic or blue star or voltas or carrier or toshiba or similar. [ warranty period: 1 2 months after the date of delivery ]
Tender For non-destruction test on concrete members visual inspection visual inspection and photography performing a visual survey of the shed steel structure as per specified in specification of documents , site testing charges concrete upv test ultra sonic pulse velocity test upv test in accordance with as per specified in specification of documents , rebound hammer test schmidt rebound hammer test for determining the concrete compressive test , half cell potential accordance in with astm c876 half cell potential to assess the probability of corrosion of reinforcement sac code 98346 , carbonation in accordance with bs 1881 201 1986 clause 2 22 carbonation test to measure extent of carbonation from the concrete surface sac code 998346 , profometer scan test on rcc members to assesss covers spacing of bars including approximate diameter bar , core test core cutting and compression test for rcc structure in accordance as per specified in specification of documents , preparing detail report as per specified in specification of documents
Tender For contract for the work of inspection of boiler water wall tubes and corrosion mapping by remote field electromagnetic testing (rfet) and boroscopic/ fibrosocpic inspection of headers and coils in boiler during annual overhaul of unit- 5 in 2 500mw, bhusawal tps.
Tender For tender for supply of non-destruction test on concrete members visual inspection visual inspection and photography performing a visual survey of the shed steel structure as per specified in specification of documents , site testing charges concrete upv test ultra sonic pulse velocity test upv test in accordance with is1331 i part i 1992 by portable ultrasonicas per specified in specification of documents , rebound hammer test schmidt s rebound hammer test for determining the concrete compressive test ref is 133 ii part 2 , core test core cutting and compression test for rcc structure in accordance with js 516 on rcc membeers as per specified in specification of documents , profometer scan test on rcc members to assesss covers spacing of bars including approximate diameter bar , half cell potential in accordance with astm c876 half cell potential to assess the probability of corrosion of reinforcement , carbonation in accordance with bs 1881 2011986 clause 2 22 carbonation test to measure extent of carbonation from the concrete surface sac code 998346 , preparing detail report visual inspection and photographs not test results analysis of not data results preparing of drawings strucrural ananysis conclusion and recommendations