Tender For bid to ras bid to ras supply of watch tower , sitc of prefab security post of size 10x12x10ft with control panel and including wpn storage safe for pers wpn , sitc of all-weather proof 24x7 operated vehicle inspection area of size 50 x 50 x25ft having infra red cameras for capturing number plate and video recording of inspection procedure. , sitc of boom barrier self operated remote controlled with span up to 25 ft , sitc of motorised ms gate heavy duty of size 29 ft x 14 ft , full height turnstile single lane , sitc of spike busters 50 tons approved capacity , day and night ptz camera vision sensor base motion detection camera with 180 tilt and span and 50 meter hd zoom alongwith nvr and cables amplifiers, and supporting software , anprc night and day hd camera with software connected through data cable trenches in m20 grade to conceal them ug with ik 10 test load casing , two way camera with storage having 180 degree tilt and span with zoom , visitor management system with software and work station , application supporting software for security related equipment , infra structure for control room , cabling conduits, boosters, amplifier, ups and other security related accessories each , sitc of fire fighting water storage 70 percentage bff and 30 percentage aff for fire fighting with high pressure water gun , plc based controlled ip 65 fixture with range of 200 meters , allied civil work and electric works for installation of security related equipment bid number/ & ( * ) : gem/2025/b/5780778 dated/ + : 10-01-2025 bid document/ 2 2 1 / 20
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For round the clock guarding arrangement by deploying private security guard through agency for safe guard the valuable office materials such as govt. properties etc.