Get complete information related to latest Laboratory Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Laboratory Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Laboratory Equipment Tenders.
Tender For supply, installation and commissioning of surveying laboratoryequipment for civil engineering laboratory in government polytechnics for women at hindupur of sri satya sai district in andhra pradesh
Tender For supply, installation and commissioning of electronic circuits laboratoryequipment for ece laboratories in government polytechnic for women, hindupur andhra pradesh
Tender For supply, installation and commissioning of digital electronics laboratoryequipment of electronics and communication engineering section laboratories at government polytechnic for women,hindupur-515201,sri sathya sai district, andhra pradesh
Tender For tender for supply of laboratoryequipments and instruments - machinery & equipment, elico cl223 colorimeter peak wavelength:410,470,490,520,540,580,610,640nmaccessories: matched test tubesphotometric range: %transmission: 0 to 250absorbance: (-)0.31 to 2.0absrepeatability:0.01 absreadability %t 1 abs 0.01light source: led detector :silicon photodiode, weighing balance weighing range: 1mg to 200gm readability: 1mg high quality industrial engineering plastic windshield with sliding doors short stabilization time failure alarm & overload protection function stainless steel pancomes with standard weight for calibration 100gm, one pan heating carousel with magnetic stirring holding capacity: 100 to 250 ml lcd display for temperature and stirring speed heating indication: red led temperature sensor temperature sensor resolution: 0.25 c rpm setting: electronic mode rpm sensor: i.r. sensor speed: upto 1500 rpm feather touch keypad hot plate top bowl type power supply 230v ac/50hzdimensions: 170 (w) 230 (l) 150 (h) mm, high precision weighing balance weighing capacity : up to 220 gm readability: 0.1mg, and repeatability 0.1 mg or less linearity: + /- 0.2mg reproducibility: /= 0.1mg standard deviation : +0.1mg pan : 90mm or more verifiability: capable of ec/oimc certification calibration: use 100gm +/-0.1mg display: touch screen led touch technology draft shields: glass shield weighing cell: monolithic weighing cell technology function: inter counting , percent weighing, weighing read out in most common international units leveling: manual adjustments: internal isocal calibration using fully automated internal temperature and time-controlled calibration and adjustment feature password protection for secure operation protects the balance against unintentional changes option to enable balance to adjust to ambient conditions with one click on the screen stabilization time : 1.5 seconds acrylic cover box with draft (one on each side and one on top) for additional protection from moisture and dust, magnetic stirrer with hot plate and external temperature sensorpower (w): 550max. stirring quantity (water)(liters):5 motor rating input (w):18 motor rating output (w):10 speed range (rpm):150-1500 speed / temperature display: digital lcd speed display resolution (rpm): 1 top plate material: stainless steel heating power (w): 500 temperature range: from room temperature to 340 c control accuracy of heating temperature: 1 c residual heating warning alarm: above 50 c control accuracy of heating temperature: 0.2 c external temperature sensor, electronic balancetop loading with transparent glass/ acrylic case cover weighing range: 0.1 mg to 200 g minimum weighing capacity: 0.1 mg maximum weighing capacity: 200 g readability: 0.1 mg display: electronic (lcd) weighing pan: stainless steel weighing pan size: 90 mm to 120 mm adjustable tare range up to maximum capacity of the balance, level indicator response time: 4 to 5 sec calibration: built in calibration/auto calibration gmp compliance unit: mg, g, ct key sound: yes; class:1; power supply: ac 220v/50-60 hz, ultrasonic processor/ probe sonicator with timer and pulse: microprocessor controlledwatts: 130 min sample size (ml): 0.15 max sample size (ml): 150 processing time from 1 second to 10 hours with timer control and a pulser display: lcd stainless steel probes: (2 mm, 3 mm, 6 mm, and 13 mm) with replaceable tip support stand with converter clamp power (vac): 220 power (hz): 50/60, high precision pen ph meteroperating temperature: 0 - 99 c measurement resolution: 0.01 ph ph range: 0.00-14 ph unit display: lcd/led ph accuracy: 0.05 temperature display fully waterproof moisture, dust, sand and heat resistant material: epoxy shaft other features: auto off function, low battery indicator, units for temperature power supply: battery accessories: calibration solution, variable volume pipette (10 to 100 l) autoclavable :autoclavable number of channels: 1 volume (metric) :10 to 100 l increments 0.2 l
Tender For tender for supply of laboratoryequipments andinstruments - machinery & equipment, hplc module pump(quaternary gradient) high precision dual plunger design. system designed to work in micro , semi-micro analytical to semi prep scale high speed double micro plunger in parallel pump with automatic pulsation correction mechanism achieving pulse free solvent delivery forced check valve designed for excellent solvent delivery control flow raterange:0.0001ml to 10.0ml/min each pump flow rate resolution of 3nl/step increment built in self diagnostic, auto purge function flow precision is less than 0.06% rsd flow rate accuracy: 1% concentration accuracy 0.5%washing kitgradient mixer,reservoir trayquaternary gradient unitdgu-20a5r bkl degassing unitmanual injector: rheodyne injector with 20 ul loop & mounting plate 25ul hamilton syringepda detectorwavelength 190 800 nm, channel 512, drift smaller than 0.5x10-3 au/hour, noise smaller than 0.6x10-5 au. wavelength accuracy should be 1 nm, linearity: 2.0au or more. a deuterium lamp [d2] and a tungsten lamp [w] should be available as light source a conventional hplc flow cell [12 l volume, 10 mm cell path length]. lamp replacement: front access, lamp life time : 2000 hours (d2 lamp)controller alite system controller, solvent bottles with cap 5/pkt, chromatographic software
Tender For supply, installation, testing and commissioning of laboratoryequipments and accessories under pradhan mantri uchchatar shiksha abhiyan pm-usha scheme at karnatak university dharwad - tga/dta thermal analyzer
Tender For m and r to talegaon chakan cwss providing services for operations of water testing laboratory and allied works related to quality of water at wtp for a period of two years and providing erecting and commissioning laboratoryequipment at wtp talegaon
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - laboratory; process heat transfer laboratoryequipments; service provider
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - laboratory; chemistry and petroleum refiningf and petrochemical (prpc) laboratoryequipment; service provider
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - chemical engineering laboraty equipment; chemical engineering laboratories (ffo, mto, ipc, cre and maintenance of laboratoryequipment (chemical engineering laboratories (ffo, mto,..