Tender For supply of vital monitoring medical equipments parts d d - saturation of peripheral oxygen probe , multi para monitor battery , non invasive blood pressure cuff , non invasive blood pressure cable with connector , electrocardiogram lead cable , adult defibrillator electrodes for reanibex 200 bexen cardio
Tender For supply of engineering laboratory equipment and machineries for department of food technology and dairy technology - purchase of engineering laboratoryequipments and machineries, venturimeter test rig1 dia cast iron venturi tube, pressure tappings, manometer, 0.5 hp motor-pump unit, orifice meter test rigorifice plate 20 mm, differential manometer, water circulation setup, reynold s apparatusglass tube, dye injector, constant head tank, flow regulator, pipe friction apparatus1 ss pipe (1.5 m), inlet/outlet pressure tapping, differential manometer, minor loss apparatusbends, elbows, sudden contraction/expansion, differential manometer, u-tube manometeracrylic body, 0 300 mm water column, mercury-free, inclined tube manometertransparent acrylic tube with adjustable scale, 0 200 mm range, piezometer board7-tube setup mounted on frame, for pressure head measurement, rotameter calibration setupflow range 0 2 l/s, with pump and flow control valves, pitot tube apparatusss tube, manometer connection, stand-mounted, reciprocating pump test rigtransparent cylinder, 0.25 hp motor, discharge measuring tank, centrifugal pump test rig1.0 hp motor, pressure gauges, energy meter, closed-loop flow system, gear pump test rigoil-compatible, 0.5 hp motor, discharge measurement unit, emptying time of tank apparatusacrylic tank (50 l), interchangeable orifices, stopwatch, free flow channel apparatusopen flume (1.5 m), v-notch weir, point gauge, recirculating pump, pipe and fittings display unitss, pvc, and ms pipe samples with elbows, tees, reducers, valve display unitgate, globe, butterfly, check, ball valves cut section models, digital tachometernon-contact optical, range 0 9999 rpm, flow measuring tankgraduated (0 25 l), acrylic, stopwatchdigital, accuracy 0.01 s, single phase transformer test bench1 kva, 230/115 v with meters for open circuit & short circuit tests, three phase induction motor (squirrel cage)3 hp, 415 v with dol starter and reversing switch, single phase slip ring induction motor1 hp, 230 v with rotor resistance starter (manual/automatic), dc shunt motor with 3-point starter1 hp, 220 v with field regulator, dc shunt generator coupled set1 hp, 220 v dc motor coupled to 1 kw generator, voltmeter(ac/dc) - 0-150v,0-300v (each 5 nos), clamp meter - 0 600v, 0 200a
Tender For e-tenders for purchase of spectrophotometer, refrigerated centrifuges, analytical balance, ph meter and other laboratoryequipments for college administrative office
Tender For corrigendum : item no 2 for supply of laboratory equipment conical flask capacity 2000 ml - item no.02 :- for supply of laboratoryequipments for trichoderma laboratory khamgaon
Tender For corrigendum : tender for supply of laboratoryequipments andinstruments - machinery & equipment, hplc module pump(quaternary gradient) high precision dual plunger design. system designed to work in micro , semi-micro analytical to semi prep scale high speed double micro plunger in parallel pump with automatic pulsation correction mechanism achieving pulse free solvent delivery forced check valve designed for excellent solvent delivery control flow raterange:0.0001ml to 10.0ml/min each pump flow rate resolution of 3nl/step increment built in self diagnostic, auto purge function flow precision is less than 0.06% rsd flow rate accuracy: 1% concentration accuracy 0.5%washing kitgradient mixer,reservoir trayquaternary gradient unitdgu-20a5r bkl degassing unitmanual injector: rheodyne injector with 20 ul loop & mounting plate 25ul hamilton syringepda detectorwavelength 190 800 nm, channel 512, drift smaller than 0.5x10-3 au/hour, noise smaller than 0.6x10-5 au. wavelength accuracy should be 1 nm, linearity: 2.0au or more. a deuterium lamp [d2] and a tungsten lamp [w] should be available as light source a conventional hplc flow cell [12 l volume, 10 mm cell path length]. lamp replacement: front access, lamp life time : 2000 hours (d2 lamp)controller alite system controller, solvent bottles with cap 5/pkt, chromatographic software
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - laboratory; process heat transfer laboratoryequipments; service provider