Tender For corrigendum : supply, installation, commissioning, training and documentation of multiparameter testing for process water laboratoryinstruments at bpcl mumbai refi
Tender For empanelment of agencies for supply of different laboratoryinstruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20
Tender For supply of procurement of certified reference material for calibration of laboratoryinstrument : : -8878061353-icp multielement standard , 8890152493- icp silicon or standard for silica , 8878061363-single element aqueous standard iron , 8878061453- phosphorus standard 1000 ppm , 8878061413- sulphur standard isooctane matrix , 8878061423- chloride standard isooctane matrix , 8878061433- nitrogen standard xylene matrix , 8878061443- naphtha standard astm d6730 1.3ml , 8864992393- oxygenate standard astm d7423 1 ml , 8878061463- cation multi element standard , 8878061473-anion multi element standard
Tender For supply of laboratoryinstrument c c - bomb calorimeter , throttling calorimeter , thermocouple calibration equipment , joules apparatus , reciprocating air compressor , single cylinder 4 stroke petrol engine test rig , single cylinder 4 stroke diesel engine test rig , steam power plat working model
Tender For corrigendum : supply of spares for different laboratoryinstruments on rate contract basis for 03 (three) years at head water works - replacement of sensor cap (ldo on line sensor), keypad for 2100p turbidity meter, sample cell /civettes for pocket colorimeter, frc, electrolyte sol for 9184sc chlorine analyser, membranes for 9184sc chlorine analyser, sample cell,1 in round glass,10, ml,w/cap,pk/6 for 2100 portable turbidity, maintenance kit, 1 year, includes tubing, caps,, funnel and fittings for cl17, for on line ph sensor salt bridges for dpdr1, tungsten lamp for spectrophotometer, (dr5000/ dr6000), tungsten (vis) lamp for spectrophotometer, (dr2000), cl17 free chlorine reagent set, lamp for 2100p turbidity meter, lamp assembly for 1720e turbidity meter, do cap for hq40d do meter, key pad for 2100q turbidity meter, keypad for surface scatter, do probe service kits for mm 378 benchtop, meter, lamp assembly for surface scatter 6/7 sc, tubing replacement kit for surface scatter 6/7, sc, filter holder f/wavelength selection for, dr5000, deauterium lamp for spectrophotometer, (dr6000), filter wheel with glasses for spectrophotometer, (dr6000), filter motor for spectrophotometer (dr6000), filling solution, 50 ml for benchtop do meter, replacement membranes for benchtop do meter, free chlorine reagent, 1000 test for pocket, colorimeter, digital extension cable (7 m) for sc1000, digital extension cable (1 m) for sc1000, wiper blades, replacement only, pkg. of 5, ldo10101 sensor cap, sc200 keypad, membranes for hanna hi 9146 do meter, electrolyte sol for hanna hi 9146 do meter, lamp hanna hi 98703-02 turbidity meter, reagent for hanna hi 96734c pocket, colorimeter, 9v battery for hanna hi 96734c pocket, colorimeter, power adaptor for hanna make ph meter, keypad for conductivity meter sension +ec71, power module for turbidity meter 21100q, cl17 lamp, stir bar for cl17, colorimeter assembly, mirror lamp, mirror, gratting, gratting with holder, filter wheel motor, lamp, 15 m cable, sensor cap for do online (wtw), sensor for tw (do) (wtw), conductivity electrode (wtw), keypad for dr1900 spectrophotometer (hach), tep 4 (buffer solution), tep 7 (buffer solution), ac power/usb adapter kit, 230 vac for hq40d, do meter, electrode for hanna hi 2215 ph meter, temp probe for for hanna hi 2215 ph meter, electrode for hanna hi 2300 tds meter, sensor for hanna hi 9146 do meter, sensor for hanna hi 5321-02 tds/conductivity, meter,1m cable,platinum 4 ring, sensor for hanna hi 2002-02 ph meter with, temp sensor, ph probe for online sc 9184 chlorine meter, ph electrode phc3005-8, w/bnc radio meter, ph meter, do probe with 3 mtr .cable for sension series, temperature probe (sensor), for ion450 ph, meter, ph electrode for online ph meter, do probe of online ldo sensor, 1720e turbidity meter, sensor only, intellical lbod probe, standard, with 1.8, m cable, sension 5131- sensor for mm 378 benchtop, meter, 5010 t combination ph electrode for ph31, glp laboratory ph meter, 5070 conductivity probe for ec71 glp, conductivity meter, conductivity probe for +ec5 conductivity meter, sension+ ph gel electrode with ceramic, diaphragm, sc200 controller, 2 channel, digital, sension ph combination gel electrode, conductivity electrode for sension+5, 9184 chlorine sensor, contacting conductivity sensor, hall sensor plate, main board, ph electrode, dissolved oxygen probe by fluorescence with, auto cleaning, turbidity probe, ph on-line electrode, general purpose, conductivity module, conductivity online electrode, k=0.1, turbidity cylinder for low range, replacement electrode for cl2 set, replacement membrane for cl2 electrode echl, refillable electrolyte (125 ml) for cl2 electrode, echl, flow meter with valve for cl2 set (6-60 l/h), el200 board, lcd colour screen (tft), 4-20 ma output module, sensolyt sea (ph electrode), standard 1000 fnu, tecl-kit chlorine 3000, ftcl-kit chlorine 3000, clf-kit 30, sc-fdo 701, controller, power circuit for hq430d conductivity/tds, hach),
Tender For corrigendum : annual maintenance and calibration contract for 3 years for laboratoryinstruments installed at various water works and water distribution stations under surat municipal corporation