Tender For corrigendum : short term e-bid for rate contract cum supply and empanelment of surgical items - "syphilisantibody (rapid) detection kits1. the assay should be based on rapid chromatographic immunoassay for qualitative detection of antibodies (lgg, lga & lgm) to tp in serum, plasma & whole blood.2. the assay should utilize recombinant treponemal antigens i.e. tp15, tpl7, tp47 against syphilis.3. the assay should be in card format.4. adequate documents detailing the principle components, bio- safety methodologies, validity criteria, interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry dates should be provides with each kit.5. the kit should have approval of the statutory authority in its country of origin.6. in case of imported kits it should be registered and licensed under the provisions of drugs & cosmetics act and rules and/or medical devices rules 2017 in india.7. in case of indigenous manufacturers should be licensed under the provisions of drugs & cosmetics act and rules and or medical devices rules 2017 issued by the competent authority defined under drugs and cosmetics act, 1940.8. the kit should have minimum shelf- life of 5/6th or 12 months (whichever is more) at the port of discharge of consignees.9. read result time should not be more than 20 minutes.10. assay should have sensitivity 100% & specificity 99 %or more with documentary evidence.11. the storage & transport temperature of the kit should be 2-30 c.12. the pack size should not be more than 50 tests wherein each test is individually", bed side leucodepletion filters for blood transfusion (for 2 unit of red cell) [ne32b] 1. filters should be able to leucodepletered cells form leukocytecontamination separately for 1 unitof red cells and for 2 units of redcells each.2. filters should be having thecapacity of log 4 reduction(99.99%)3. filters should not carry anycharges it should be neutrallycharged.4. filters material should bepolyester woven / non- woven.5. leukocytes should beconsistently averaging less than0.5x105 residual leucocytes forone unit of red cell and 0.2*106for two units of red cell. rbcrecovery should be averaging morethan 90%.6. filters should have hard / softhousing for optical monitoring.7. filtration loss should not bemore than 35 ml for one unit redcell.8. should have integrated 40 m,micro aggregate filter.9. should be us fda/ europeance certified., hepatitis b surface antigen (elisa) testing kits iv generation/high sensitiveshould have microplate elisa coated with either polyclonal or monoclonal antibodies to hbsag and either polyclonal or monoclonal antibodies in conjugate. the assay should be able to detect all the 11 subtypes (ad & ay subtype) including mutant strains. the assay should be able to detect surface antigen to hepatitis b virus., hbsag (rapid test)
Tender For supply of ir viewer with nd filter , ir cards , thermal camera , kinematic mount for large circular optics dia 100mm , kinematic mount for circular optics dia 50mm , kinematic mount for circular optics dia 25mm , v type adjustable lens mount: dia 100mm , beam dump , optical post type-1 , optical post type-2 , optical post type-3 , switchable magnetic post bases , manual lab jack , optical rail: length 500mm , carrier for optical rail , five axis positioner , xy post base , table clamps , x-y liner stages , round apertures type 1 , round apertures type 2 , round apertures type 3 , absorptive nd filter kit , interference filter , optical power head & compatible analog power meter , shearing interferometer
Tender For bid to ras supply of l2 switch 24 port poe , 14u racks , 1 kva ups isolation , utp patch cord 3 mtr , ofc 12 core , utp cable cat6 1 roll , io ports , ip 68 optical patch cord , fdms , display screen 65 inch , management console , hmdi switcher 8x8 , ups 60 kva system with battery back-up , 340 ka 3 phase block move based surge protector , 125 amp 280 ka 3 phase multi stage series power filter , 40 amp 280 ka 3 phase multi stage series power filter , 480 ka 3 phase 7 mode digital grounding system , 80ka dc digital grounding system , power management and monitoring system with centralised display and software , deep driven chemically charged copper earthing , transient earth bonding system in ip 68 enclosure
Tender For supply of set of spares required for maintenance of the optical emission spectrometer, make: metal-power, model: 10008x, metal analysis: (1) mini sample adapter= 01 nos, part no. 50113010990019 (2) exhaust filter bottle=01 nos, part no. 50111414020004(3) cleaning brush for pointed rod of cb= 01set, part no. 50113010990001(4) o-ring set for m1008i cube-cb= 01 set, part no. 50113010990008(5) fanfilter= 01 set, part no. 50111610990011 (6) duv entwin m1008i cube= 01 nos.,part no. 50113410050002(7) vis entwin m1008i cube= 01 nos,part no. 50113410050003 (8) 5 bar ra regulator= 01 nos.part no. 501133109900045 [ warranty period: 30 months after the date of delivery ]