Tender For supply of standard tongue rail of sej test piece for sensitivity setting of ultrasonic equipment for 60 kg rail. [ warranty period: 12 months after the date of delivery ] ]
Tender For supply of permanent magnetic yoke (rope type) to carryout magnetic particle testing (wet and dry method) as per. is: 3703/2004.the technical specification is given below; 1) lifting power : 20kg or more with pole spacing 100mm.2)magnetic field: constant level.3)poles adjustment : 0-300mm. 4)tangential field strength :minimum value of 30g.5)equipment weighs not more than 400grams.. note: item to be supplied along with calibration, test certificate and warranty certificate and equipment manual. as per specification is: 3703/2004(copy enclosed) or latest make: orion/ferflux/ecci/magnaflux/pic /sims or equivalent [ warranty period: 30 months after the date of delivery ] ]
Tender For providing of testing service for on-board /commissioned equipment/ instrument related to plant - wt 5176g work of carry out corrosive test of various ms structure of coal handling plant of ukai tps chpm; as per schedule b and scope of work mentioned in atc; as p..
Tender For supply of ngc_iads_main equipment , ngc_iads_cables , ngc_iads_installation materials , ngc_iads_lifting gear and driling jig , ngc_iads_on board spares , ngc_iads_special tools and test equipmnt , ngc_iads_t and t spares , ngc_iads_instl and commisng spare , ngc_iads_documentation hard copy , ngc_iads_documentation soft copy in cd , ngc_iads_ietm in portable media , ngc_iads_binding data , ngc_iads_qap , ngc_iads_design review , ngc_iads_technical assitance-training as per sotr- mom of tnc , ngc_iads_simulator , reduction for pre- ponement of delivery per annum basis in percentage , charges for delivery postponement per annum basis in percentage , charges for warranty extension per annum basis in percentage
Tender For supply of ngc_swiss_main equipment , ngc_swiss_cables , ngc_swiss_installation materials , ngc_swiss_on board spares , ngc_swiss_special tools and test equipment , ngc_swiss_testing and tuning_t and t spares , ngc_swiss_external interface simulator , ngc_swiss_swiss simulator , ngc_swiss_documentation hard copy , ngc_swiss_documentation soft copy in cd , ngc_swiss_ietm in portable media , ngc_swiss_binding data , ngc_swiss_qap , ngc_swiss_design review , ngc_swiss_service of engineers-technici , ngc_swiss_training , reduction for pre-ponement of delivery per annum basis in percentage , charges for delivery postponement per annum basis in percentage , charges for warranty extension per annum basis in percentage
Tender For supply of digital insulation resistance tester to check ir of electrical equipment . test voltages 100v/250v/500v/1000v for insulation resistance upto 5 giga ohms. ac voltage 30v-750v. display count 2000. built in lcd display, cat iii 600v safety rating. supply includes batteries, leads & user manual, nablcertified lab calibration report .tester shall be as per stan one model no. -sit 500.accepted make-stan one or fluke or similar. [ warranty period: 30 months after the date of delivery ]
Tender For purchase of equipment for electronics and communication department - 100mhz/2 channel digital storage oscilloscope(dso), sample rate 1gsa/s, record length - 14mpts, wavwform capture rate-400,000 wfm/s, serial decode/trigger functions, advanced math operations-fft, d/dt, integrate, square root 38 parameters automatic measurements, 7 inch tft lcd display, newest generation of spo(super phosphor oscilloscope) technology support usb host, usb device (usb tmc), lan (vxi-11), gpib (optional), pass/fail, trigger out, impts, 500uv/div sensitivity, 2 channel 3mhz function generator with modulation, 3 mhz function generator with sine, square, triangle, ramp, pulse, ttl & dc, frequency range 0.3hz to 3mhz, amplitude and frequency display, internal and external modulation by any signal by am,fm,pwm,pam,fsk,ask, auto ranging 40mhz frequency counter, auxiliary generator with frequency 20hz-20khz, square wave rise time- better than 50ns, dual channel power supply 0-30v continuous variable regulated 30v-2a, 0 to +/- 15v-1a, 5v-5a multiple power supply, dc 0 to 30v/2a, 0 to +/- 15v/1a tracking, 4.5 to 5.5 / 5a digital display for voltage and current protection against overload and short circuit, adjustable current limiter, constant current & constant voltage, multimeter - digiital - dc voltage 1000v, ac voltage 1000v, dc accuracy +/- 1% +3 digit, current dc 10amp, ac 10 amp, dc accuracy +/- 1.5%+3 digit, ac accuracy +/- 1.5% +3 digit, resistance 40 mohm - resistance accuracy +/- 1.5% +3 digit, capacitance :1000uf; capacitance accuracy +/- 5% + 5 digit. cat iii 600v saftey rating, bigger display with bright white backlight. over voltage indicator, frequency and temperature measurements, voltage, resistance, continuity, capacitance measurements, input terminal for ac and dc current measurements upto 10a, diode test, data hold, min/max ammeter and voltmater included.
Tender For corrigendum : repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; tender for the job of obtaining consent to establish for hter scheme at rcf thal unit through nipl route; as per scope of work; a) safety violation by contractor employee at work place: 1) working without wearing safety helmet (per person), 2) working without wearing safety shoes (per person), 3) working without wearing safety goggle &/or hand gloves during handling of hazardous chemicals, acid/alkali etc. (per person), 4) working without wearing safety belt (double lanyard full body harness) for height jobs above 2 meters. (per person), 5) working without wearing face shield during cutting, welding, grinding activity and during maintenance work on process lines and equipment. (per person), 6) not using ppe, tools/tackles as mentioned in safety work permit (per person), 7) working without valid test certificate for lifting tools/tackles (per incidence observation), 8) working without appropriate electric plug-pin, elcb/rccb/rcbo (per incidence observation), 9) working without a valid safety work permit (per incidence/ observation), 10) permit not available at site (per incidence/observation), 11) gas cylinder without flash back arrestor (per incidence observation), 12) gas cutting set with damaged hose pressure gauge without valve key (per incidence/observation), 13) gas cylinder without trolley (filled and empty) (per incidence/ observation), 14) unauthorized personal entering into cordon off area (per incidence/observation), 15) faulty wire/cable laying on ground or using snapped cables (per incidence/observation)., 16) improper hand tool or power tools (per incidence observation), 17) smoking at work place area. (per person), 18) found in intoxicated state (per person), 19) violation of road rules (per incidence observation), 20) b) safety violations by transport contractors, 21) faulty hazchem displayed on tanker (per incidence observation), 22) one pvc/tychem suit set if available (per incidence/ observation), 23) both pvc/tychem suit set are not available (per incidence observation), 24) fire extinguisher without hydro test. (per incidence/ observation), 25) trem card not available (per incidence/observation), 26) hazardous chemicals transportation training of driver by authorized agencies. (training card not available with driver) (per person), 27) lying/resting below the vehicle(per incidence/observation), 28) any other deviation found as per checklist for tankers (per incidence/ observation.