Get complete information related to latest Lcr Bridge Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lcr Bridge Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lcr Bridge Tenders.
Tender For supply of various items of lab equipments for govt. p g college guna district guna (m.p.) under p m usha pariyojna 4th call - supply of various lab equipments items for govt. p g college guna district guna (m.p.) 4th call, waterand soil testing analysis kit (digital) : range ph 0 to 14.00 resolution ph 0.01 accuracy ph 0.01 1 digit temp. comp. 0 to 100 deg. c., water bath (06holes) : 6 hole8 ltrs., waterbath(12holes) :12 hole 20 ltrs., water distillation apparatus(single distillation unit 2 litre/hour) : single distillation 5 litres, analytical balance : least cosunt 0.0002g, analytical weight box : 1-100g, fractional weight box : 1-500mg, physical balance : 250gm accuracy 0.1g, digital balance : least count 1mg, single pandigital balance : 0.1mg 200g, digital photoelectric colorimeter : 8 filter,1 ml, digital potentiometer : with hot plate and electrodes, digital conductometer : with cell 1cc and 0.1cc, d.o. meter : polarographic do range: typically 0 to 90 mg/l (milligrams per liter) or 0 to 600% saturation.rdo (optical) do range: usually 0 to 50 mg/l or 0 to 500% saturation., digital naphelo/turbidity meter : digital turbidity cum nephelometer range:-, 200,1000 ntu/jtu resolution:- 0.01 ntu/jtu accuracy:- 3% fs, 1digit display:- 3 digit 7-segment led light source:- ir led detector:- photodiode sample system:- 60 x 25mm clear glass test tubes power:- 230 v 10% ac, 50 hz accessories:- test tube set of 2, operation manual, dust cover, polarimeter half shade : the specific rotation ( ) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/l, a temperature (usually 20 c), and a light wavelength (usually sodium d line at 589.3 nm), melting point apparatus :melting-point measurement range: room temperature - 400 c setting rate of the starting temp. : 50 c~400 c 5 min; 400 c~50 c 7 min minimum digital display: 0.1 c size of the capillary: 1.4mm (outside diameter) 1.0mm (inside diameter), 90mm equipped with color camera and color monitor to observe melting point with ease validation program for standard samples 8 operator names can be storedgraphic lcd display to display all test parameters & test instructions, digital melting point apparatus :melting point measurement range : ambient to 300 deg c starting melting point temperature : settable from 50 to 300 deg c heating time : 3 minutes (up to 300deg c) cooling time : 5 minutes (from 300 deg c) accuracy : +/ 0.5 deg up to 200 +/ 0.8 deg from 200 to 300 temperature display resolution : 0.1 deg c rate of heating (deg c per minute), abbe refractometer : safety bs en 60950-1:11/2006 emc en 55024 : 10/2003 en 55020 : 11/2005, tlc kit : outstanding standardization and quality control exceptional adherence, hardness and surface homogeneity. analyzing samples with high matrix- load without sample preparation. multiple samples analyzed in parallel.highly cost-efficient, fast and economical, centrifuge : 6000rpm, corkboring machine :adjustable guide that permits holes to be bored in any part of a stopper, the knurled chuck - 9/16" (14mm) shank of the eight, plated-steel borers included with the unit. the steel borers range from 3/16" to 5/8" (4.8mm to 15.9mm) in 1/16" (1.6mm) increments,, distillation apparatus : single distillation 5 litres, oven hot air : 14" 14" 14 , voltage stabilizer : 2kv, vertex shaker : 6 tube capacity, mixer small : moter capacity 900 watt, water bath(cu) : 4 , heating mantle with energy regulator : 500 w,2litre, single crucible heater : helical wire coil moldatherm insulation platinel ii thermocouple with 10tm compensated lead wire and polarized plug ceramic fiber hearthplate programmable heat-up to setpoint temperature indicates setpoint and process temperatures temperature: 1200 c (2192 f) maximum crucible sizes: 5 (top vestibule id) x 8 (heated depth), water bath rectangularsingle walled : 6 hole 8 ltrs., water bath rectangular :2 hole, kjeldahl distillation unit : unit of 3 tests, microwave oven : 30 ltr co
Tender For supply of aluminium slide tray , slide storage box , slide staining rack or rod , slide staining trough or glass , test tube 5 ml , test tube 10 ml , test tube 15 ml , test tube rack or basket with 24 holes , test tube holder , analytical balance , k2 edta tube , red capped blood collection vials , isopropyl alcohol , urine container sterile 50 ml , pipette stand acrylic , spirit lamp , surgical spirit , tissue paper microscope grade , giemsa stain ready to use , microscopic glass slide , cover slip rectangular , cover slip square , measuring cylinder graduated 100 ml , measuring cylinder graduated 50 ml , distilled water 5 litre capacity , centrifuge tubes conical bottom 15 ml , conical flasks 50 ml , conical flasks 100 ml , conical flasks 250 ml , conical flasks 500 ml , conical flasks 1000 ml , beakers 100 ml , beakers 250 ml , beakers 500 ml , coplin plastic screw cap jars , laboratory forceps , dpx mountant , sodium hypochlorite solution 5 percent , glass marking pencil or diamond pencil , tourniquet , disposable syringe 10 ml , disposable syringe 2 ml , disposable syringe 5 ml , neubauer improved counting chamber , disposable esr tubes , disposable plastic test tubes 5 ml , capillary tubes without heparin , blood lancets , filter paper grade 393, and diameter 125 mm , stop watch , cotton roll - absorbable sterile , microscope immersion oil type a b , wash bottle 500 ml , micro pipette tips non filter 200 ul , micro pipette tips non filter 1000 ul , micro pipette filter tips 200 ul , micro pipette filter tips 1000 ul , eppendorf microcentrifuge tubes , grey capped blood collection vials , blood grouping antisera anti a and anti b and anti d , typhoid igm igg combo rapid test kit , widal test kit slide agglutination - to, th, ah, bh with nc,pc , dengue combo kit , troponin i , troponin t , urine pregnancy test kit , hbsag rapid test kit , hiv 1 2 ab rapid test kit , hiv tridot test kit , hiv comb aid test kit , anti hcv rapid test kit , syphilis rapid test kit , ra factor test kit , crp latex agglutination test , malaria antigen rapid test kit , multistrips for urine test , stool occult blood testing kit , micropipette variable volume 1-10 microlitre , micropipette variable volume 10-100 microlitre , micropipette variable volume 20-200 microlitre , micropipette variable volume 100-1000 microlitre , ph meter digital //bid details 2 / 60
Tender For supply and installation of electrical consumables for day-to- day maintenance for a period of 02 years at goa college of engineering. - supply, installation, testing and commissioning of 18 /20 watt led tubelight luminaire complete with all accessories etc. as required of make: bajaj cat no. bclab 20wledp/make: crompton cat no. ccs- 100-20- 65-hl2-dp-nwh;m ake jaquar cat no. lglz01020xw or equvivalent in wipro/philli ps/great white etc as per instructions of the engineer incharge., supply of 9w led bulb , of make panasonic, ( cat no:pbum36093) or equivalent in bajaj/havell s/panasonic/phi lips /jaquar/le gero/orient/bio con. complete as required. (equivalent to be approved by engineer in-charge ), supply and fixing of 2.5 microfarad fan capacitor of reputed brand complete as required., unarmoured pvc /xlpe1100 v cable 2 core 10 sq.mm aluminium, supplying and fixing brass batten/ angle holder including connections etc as required., re-wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in the existing surface/ recessed steel pvc conduit or casing caping including dismantling as required.; group b, supplying and drawing following sizes of frls pvc insulated copper conductor single core cable in the existing surface/ recessed steel pvc conduit or casing caping including dismantling removing old wires as required.;(11) 2 x 2.5 sq.mm, supplying and fixing following size modular pvc box alongwith modular base and cover plate for modulator switches in recess etc. as required;(i) 3 module cat b, supplying and fixing following size modular pvc box alongwith modular base and cover plate for modulator switches in recess etc. as required;(k) 6 module cat b, wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm fr pvc insulated copper conductor single core cable in pvc casing caping with modular switch modular plates suitable size modular surface box of specified category and earthing the point with 1.5 sq.mm fr pvc insulated copper conductor single core cable etc. as required.;(b) group b -- with cat b modular accessories, supply and erecting of 56 inch (1400mm sweep) ceiling fan double ball bearing type complete with all accessories .; cat b, supplying and fixing 6 a to 32 a c series mcb suitable for lighting and other loads of following poles in the existing mcb db complete with connections testing and commissioning etc as required.;(f) sp cat b, supplying and fixing 40 a c series mcb suitable for lighting and other loads of following poles in the existing mcb db complete with connections testing and commissioning etc as required.;(f) sp cat b, supplying and fixing 63 a c series mcb suitable for lighting and other loads of following poles in the existing mcb db complete with connections testing and commissioning etc as required.;(j) tpn cat b, wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor single core cable in the independent pvc casing capping of appropriate size as required.;(b) 2 x 2.5 sq. mm + 1 x 2.5 sq.mm earthwire (20mm casing ), erection of wall bracket/ ceiling fittings of all sizes and shapes containing upto two gls lamps per fitting complete with all accessories including connections etc as required., din hrc fuses size size 0 200a, supply installation testing and commissioning of electronic type three phase energy meter (kwh) 4 wire isi marked in polycarbonate or sgheet steel body ( base mounting type) with counter display /lcd display with elt in class 1.0 50 hz 240 v. ac duly tested by mrt along with test certificates complete as required of following capacity of make l & t only.;(c) 50 to 100 a, providing and fixing following capacity tpn disconnector fuse switch unit in ss enclosure without hrc fuses including drilling holes in cubicle panel making co