Get complete information related to latest Led Signal Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Led Signal Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Led Signal Tenders.
Tender For supply of shunt ledsignal lighting unit for subsidiary color light signals for railway signaling as per rdso specification no. rdso/spn/153/2023. rev. 5.0 or latest. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of main ledsignal lighting unit working on 110v ac retrofittable in existing cls housing as per rdso specn. no. rdso/spn /199/2025 rev.1.2 with amendment 1 or latest. (sa23002, s23024/m)yellow aspect. rdso id-3100194, sub item id- 3100194002. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted:max 8 lacs ] ]
Tender For supply of main ledsignal lighting unit working on 110v ac retrofittable in existing cls housing as per rdso specn. no. rdso/spn /199/2025 rev.1.2 with amendment 1 or latest. (sa23002, s23024/m) green aspect. rdso id - 3100194, sub item id-3100194002 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted:max 8 lacs ] ]
Tender For corrigendum : supply of various signaling spares of siemens make - chk fuse 50ma , profibus a2v00001136165 , profibus a2v00001081707 , profibus a2v00001856577 , opg tongue , voltage cut off switch , ecc ps back pcb , interface module 10w , profibus a2v00082018132 , switchover board 12.5khz , cpci simis lan card , olm p11 , melde2 card , point machine motor , olm p12 , relay module rememo 612 , power supply board , loop function control unit , operation and monitor unit for loading pc , olm g12 , olm g11 , point machine non trailable left , cpu 850 extendend , cpci simis power supply pack 250w , signal yellow led module led70 , front cable of vesuv3 card
Tender For supply of relay room opening register with hard board binding. performa as per sample format -"d" (also available in signal store.) specification as per under. i) printing in letter size paper 80 gsm ii) total 100 pages each register and 1 covering page. (xerox of sample format attached) iii) printing sample format available in the office of sse/sig/store/dhn iv) binding style- case bound (hard cover) [ warranty period: 12 months after the date of delivery ] ]
Tender For supply of route ledsignal lighting unit,110vac, retrofittable in existing cls housing and compatiblewith ac led ecr as per rdso specification no. rdso/spn/153/2011,rev.4.1 draft or latest. as per drg.no. na specn: rdso specn no. rdso/spn/153/2011 rev. 4.1 draft (with latest amendment) [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted:max 8 lacs ] ]
Tender For supply of 2.2 kw ac crane drive , 5.5 kw ac crane drive , 11.0 kw ac crane drive , 22.0 kw ac crane drive , 37.0 kw ac crane drive , 55.0 kw ac crane drive , 75.0 kw ac crane drive 3 phase, digital ac crane drive 2.2 kw, ac drive should be suitable for heavy duty operation of 2.2 kw. offered ac drive should be suitable for crane-hoist operation. if, separate software required for crane application, it must be clubbed with supply of material. ac input voltage: 380 to 480v ac 10%, 3 phase, 3 wire, 50 hz; mode of control: bi-directional fully controlled 3-phase ac; speed regulation: 1% of base speed; braking: suitable dynamic braking resistance and chopper unit (external or in-built); acceleration time: 0.1 to 1000s or better; deacceleration time: 0.1 to 1000s or better; overload: 150%-1min, 200%-3.0s; ambient temperature: 0 to 50 c (derating shall not occur below 50 c. in the event that derating occurs below 50 c, the supplier shall provide a higher-rated drive to match the requirement); rated current at 50 c: min. current should be 5.5 amps at 50 c; high starting torque at low speed: 200% starting torque at 0.3 hz; two analog inputs: two nos. analog inputs having signal voltages of 0 to 10 vdc or 4 to 20 ma (configurable); two analog outputs: two nos. analog outputs having signal voltages of 0 to +/-10 vdc or 4 to 20 ma (configurable); six digital inputs: pnp/npn; one relay output: with short-circuit and overload protection; two digital outputs: with short- circuit and overload protection; brake release signals: outputs braking signals based on inverter operating conditions to prevent cargo bed rollback and overrunning; load adaptive control: when the actual load level is lower than the configured load level, the system can be operated at a ratio-multiplied speed (in terms of the configured frequency), resulting in significantly better efficiency; load ) /bid number : gem/2026/b/7563714 * /dated: 20-05-2026 & & / bid document 1 / 29 frequency), resulting in significantly better efficiency; load limiter: maintains the safety and rescuability of suspended loads by stopping when excessive torque is detected and by allowing operation only in the direction opposite to that in which the excessive load was detected; cooling capacity degradation alarm: detects and displays cooling capacity drop due to cooling fin clogging caused by dust and cooling fan airflow reduction; igbt life expectancy forecasting: estimates the power cycle life expectancy of the main circuit s igbt semiconductor device temperature due to frequent acceleration and deceleration stoppages, and displays the estimate before the design life is reached; protection: it must have all standard protections like stall protection, instantaneous power failure, single phasing, over voltage, under voltage, over current, inverter overload, thermal overload etc; display console: it must have alpha numeric display console for programming of drive, fault display and operating condition; dynamic qr code: it must have dynamic qr code for trouble shooting; tuning facility: it must have auto tuning facility. this must enable perfect matching of motor coupled to load with regards to optimum acceleration time, deceleration time, speed regulation etc; drive programming software: suitable drive programming software along with necessary connecting cable and adapter for connection with laptop and drive should be provided to get online with the offered drive (laptop not in scope); automatic voltage regulation: it must have automatic voltage regulation function to maintain high starting torque even at reduced voltage; regenerative option: it must be capable of regenerative operation; communication protocol: modbus (rtu/serial) or ethernet (tcp/ip); make of drives: fuji- electric/yasakawa/schneider/abb only; suitable dynamic breaking resistance unit of 60% wattage rating of drive, however the value of resistance is to be decided by manufacturer as per their technical manual for crane-ho