Web Analytics Made Easy - StatCounter

Level Control Valve Tenders

Get complete information related to latest Level Control Valve Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Level Control Valve Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Level Control Valve Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :44668248 Due date: 01 Apr, 202601 Apr, 2026 NA
Tender For disposal of miscellaneous scrap materials (metallic) metal scrap mild steel(ms) , metal scrap galvanized iron(gi) , metal scrap aluminium , metal scrap powder coated gi , metal scrap copper , metal scrap copper tube/ coil , metal scrap stainless steel (ss) , metal scrap cast iron (ci) , used pipes mild steel (ms) , used pipes stainless steel (ss) , used pipes galvanized iron (gi) , used valves & fittings cast iron (ci) , used valves & fittings mild steel (ms) , used valves & fittings stainless steel (ss) , used valves & fittings brass , used valves & fittings bronze/phospherous bronze , used valves & fittings plastics , used flanges mild steel(ms) , used flanges stainless steel (ss) , used flanges galvanized iron (gi) , used flanges cast iron (ci) , used metal fittings mild steel(ms) , used metal fittings stainless steel(ss) , used metal fittings galvanized iron(gi) , used metal fittings cast iron (ci) , used duct galvanized iron(gi) , used duct aluminium , used panels stainless steel(ss) , used panels powder coated gi , used panels aluminium , used belt rubber , used belt polyurethane (pu) , used bearings , used pump , used sheet galvanized iron(gi) , used sheet aluminium (al) / al powder coated , used sheet miled steel(ms) , used sheet stainless steel(ss) , used trolley wheel stainless steel(ss) , used trolley wheel miledstee(ms) , used trolley wheel galvanized iron(gi) , used trolley wheel polyurethane (pu) , used pneaumatic cylinder , used pneaumatic fittings , used hoses polyurethane (pu) , usedhoses braided , used hoses nylon/cotton (fire hose) , used heat exchanger copper (cu) , used heat exchanger aluminium (al) , used heat exchanger miledstee(ms) , used ac compressor (hermatically sealed) , ss needle scrap , copper wire scraps(99.99% pure)winding operation rejection , used hepa /microwave / pre filter , electrical scrap (industrial socket, plug, switch gears, controllers, , timer, contactors mcb, mccb, elcb, rccb, indicator lamp , switch , board, control switches , meters, capacitor, relay , light fixtures, , starters, solenoid valves, cooling fan, exhaust fan leaf, rosette box) , used tube / light led , instrumentation scrap , used motors motor above 0.5 hp , used motors motor below 0.5 hp , old cctv cameras/ dvr , used cable (copper) , used cable (aluminium) , electrical motor housing (scrap) , old fire extinguisher- 2 kgs , old fire extinguisher- 4 kgs , old fire extinguisher- 6 kgs , modular puf panel , used aluminium door , modular puf panel (ss sheet cladding) , used acp sheet

State Government

CTN :43835240 Due date: 13 Apr, 202613 Apr, 2026 NA
Tender For corrigendum : supply of various sizes of angle needle valves, swing check valves, globe valves and gate valves required for cooling water system, oil supply system and compressed supply system at slbhes, srisailam dam west, nagarkurnool (dist) - 509326, telangana.

Central Government/Public Sector

CTN :44339856 Due date: 10 Apr, 202610 Apr, 2026 NA
Tender For corrigendum : two years annual rate contract for the supply of tube fittings, ball valves, needle valves, manifolds as per tender specification

CTN :42579205 Due date: 17 Apr, 202617 Apr, 2026 NA
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr

State Government

CTN :44051277 Due date: 06 Apr, 202606 Apr, 2026 NA
Tender For corrigendum : supply of needle valves for bfp oil and feed water impulse lines of tm/stage-i/btps

CTN :44512544 Due date: 07 Apr, 202607 Apr, 2026 NA
Tender For supply of ccuc flow control valve fv 5002 , ccuc level control valve lv 5001

Central Government/Public Sector

CTN :44448043 Due date: 03 Apr, 202603 Apr, 2026 NA
Tender For supply of spare parts/consumables for high pressure reactor with gas booster system - reactor head ss316l 350 bar with fittings, vessel ss316l 350bar 142mmx 350mm, vls6020, solid stirrer shaft ss36l, 430mm, sssl008, head gasket pure grafoil 300 bar, hgggd004, stirrer clamp assembly with bolt and bush 350bar, scsl008, serpentine cooling coil ss316l 350 bar, ccs4027, thermowell ss316l 350 bar, thsl031, ring sparger diptube assembly ss316l 350 bar, dtsl028, adapter pressure gauge with cooling jacket ss316l, adsl020, rupture disc assembly ss316l, rysl009, adaptor y type ss316l 1/4in nptm, adsl001, needle valves 400 bar ss316l 1/4in npt, nvs6005, bourdon pressure gauge 400bar ss316, pgb0019, pressure sensor 0-400bar ss316, psnf007, impeller pitch blade turbine ss316l-350bar, ipsl006, body clamp pair 1960dx102idx98mm lng., hsn code 84199090