Get complete information related to latest Lever Pin Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lever Pin Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lever Pin Tenders.
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c
Tender For supply of vehicle spare parts-- oil filter for bolero bs-vi , fuel filter bolero bs-vi , hub oil seal rear bolero bs-vi , oil filter for m m thar , hub oil seal front, rear for m m thar , air filter for m m thar , fuel filter for bolero camper , air filter for bolero camper , oil filter for bolero camper , rod spring bush metal type for bolero camper , shackle bush balencing rod for bolero camper , front hub oil seal inner for bolero camper , oil filter for tata 407 bs-vi , fuel filter for tata 407 bs-vi , r whell oil seal inner for tata 407 bs-vi , f wheel oil seal inner for tata 407 bs-vi , rod spring shackle pin bush for tata 407 bs-vi , clutuh cly repair kit for tata 407 bs-vi , rear wheel cyl repair kit for tata 407 bs-vi , master cyl r kit for tata 407 bs-vi , check not lock whasher for tata 407 bs-vi , oil filter -t712 bus , fuel filter t-712 bus , sleeve cyl repair kit for tata 1212 bs-vi , fuel filter -water supretor for tata 1212 bs-vi , f wheel oil seal outer, inner for tata 1212 bs- vi , r wheel oil seal outer, inner for tata 1212 bs-vi , clutch cyl repair kit for tata 1212 bs-vi , check not lock whasher for tata 1212 bs-vi , oil filter for tata 1212 bs-vi , oil filter for tata 1212 bs-iv , oil filter -tata-713 bp , insulation tape , lt wire 4-5mm , emery pepper , fog light bulb 12v , bulb 12v21w s-f , bulb 12v5w s-f , fuse 10,15,20,30 and 40 amp , wildign rod , anabond , val pin , omini patch big ) /bid number : gem/2025/b/6980615 * /dated: 11-12-2025 & & / bid document 1 / 34
Tender For corrigendum : supply of procurement of spares for ece make circuit breaker c c > f> f -shunt trip coil assy part no 1650ts or equivalent , heavy duty earth leakage relay wth leakage display, time lag facility and cbct part no ea6641 or equivalent , idmt relay complete with 2 over current and earth fault or high set part no ea6561 or equivalent , carriage asslembly part no bd5550 or equivalent , guide pin small part no pd3597 or equivalent , guide pin big part no pd4043 or equivalent , isolating spout assy with nylon shroud part no bc9977 or equivalent , interlock assembly part no bd4861 or equivalent , high speed tripping relay part no ea6890 or equivalent , under and over voltage relay. part no ea6591 or equivalent , complete wiring set for ocb ece part no bd5988 or equivalent , power pack unit 110v dc part no bd5999 or equivalent , operating mechanism complete set part no bd4911 or equivalent , jaw contact assembly set part no bd4050 or equivalent , partition plate assembly part no bd5255 or equivalent , assorted hardware bd9295 tray 16 part no bd9295 or equivalent , rod holder assembly part no bd4921 or equivalent , push trip assembly part no bd4920 or equivalent , moving contact assembly part no bd5551 or equivalent , fixed contact assembly 400a part no bd4510 or equivalent , earting bar contact part no bd8810 or equivalent , instrument chamber box complete with internal wiring part no bdw7771 or equivalent , ocb rasing and lowering handle part no bd4718 or equivalent , cartridge fuse 2a part no bd5412 or equivalent , lt fuse with base part no bd4443 or equivalent ) /bid number : gem/2025/b/6816822 * /dated: 21-11-2025 & & / bid document 1 / 26
Tender For corrigendum : supply of spares of ge make lt switchgear installed in electrical and chp circle at stps,suratgarh - shunt trip assy.with coil-220vdc for acb m610 type,1000a and m16 type,1600a.cat.no.pga0100874, moving contact block for acb m610 type,1000a and m16 type,1600a. cat.no pga0100040, top fixed contacts for acbm610type,1000aand m16type,1600a.cat.no pga0100271, trip roller with link for acb m610type,1000a and m16type,1600a. cat.nopga0130224, trip prop for acb m-610type,1000a.cat.nopga0100117, lt disconnect moving for acb m-610,1000a & m-16,1600a ,cat.no.pga0100171, lt disconnect fixed for acb m-610,1000a&m-16,1600a ,cat.no.pga0100172, spring limit switch assy. mws for acb m-610,1000a & m- 16,1600a,cat.no.pga0140911, spring limit switch for acb m-610,1000a&m-16,1600a ,cat.no.pga0120373, closing coil accesso. for acb m-610,1000a & m-16,1600a ,cat.no.pga0120676, aux. switch mounting plate for acb m-610,1000a & m-16, 1600a,cat.no.pga1100423, shunt trip coil 220v dc for acb m-610, 1000a & m-16,1600a, cat.no.pga0100039, shunt trip assy. with coil 220v dc for acb m-3032,3200a ,cat.no.pga0100874, spring limit switch for mwspga0140911, model m3032,3200amp., spring release ass.220v dc for acb m-3032,3200a,cat.no.pga0100879, shunt trip coil assy. with coil typea0100874, modelm610, top fixed contacts typepga0100285, modal3032, bottom fix contact pga0100283, model m3032,3200, aux. switch for acb m-610,1000a & m-16,1600a, cat.no.pga8010001, lt disconnector fixed pga0100172, model m3032, 3200amp., cmm-125 switch fuse unit125a, 3pole,415v without fuse, cmm-200 switch fuse unit200a, 3pole, 415v without fuse, cmm-400 switch fuse unit400a, 3pole, 415v without fuse, moving contact carriage for cmm-125,125a, 3pole, moving contact carriage for cmm-200, 200a, 3pole, caliper contact for cmm-125, 200, 250& 400, dowel pin for cmm-125 to 400
Tender For corrigendum : the work of shifting of line full deposite scheem at various place under edd-sadabad hathras. - safe carriage of following material from electricty store center hts to pit site of work through the kacha and pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, t&p, etc. which required for proper completion of work.(distance 00-50 kms.), 8.5/9 mtr. long pcc poles., 9/11 mtr. s.t. poles, acsr weasel conductor, earthing complete, shackle insulator, stay set complete, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, 50/95/120 sqmm. ab cable, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, guarding angle with clamp, g.i wire 6/8/10 swg, neutral cum earth wire, cable jointing kit, 11 kv xlpe cable, 25 kva t/f, 63 kva t/f, 100 kva t/f, errection of following poles including cutting of kharanja/mettalic road/concrete portion while digging pit & complete h.t./l.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t&p and carrier etc. required for proper completion of work., pcc poles 8.5/9 mtr., stp 9.0/11 mtr., errection and grouting of stays as per respo norms and as per direction of supervising engineer. grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost., fixing of earthing rod as per respo norms and as per direction of supervising engineer., safe installation of following new/repaired cousted t/f on newly constructed double pole in proper alignment direction & making all ht/lt connection., 25 kva t/f, 63 kva t/f, 100 kva t/f, laying, sagging and stringing and jumpering / binding etc. of new & old acsr weasal conductor / gi in 11 kv / lt lines as per respo manual and as per direction of supervising engineer., acsr weasal conductor, 50/95/120 sqmm. ab cable, xlpe cable, providing & fixing of following clamps, 11 kv x arms clamps for stp/pcc pole, nut,bolt & washer, 11 kv f clamp for stp/pcc pole, earthwire clamps, lt clamp with nut & bolt, cable jointing kit, cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer, guarding/reguarding of 11 kv line by laying, stringing, sagging and binding of 2 nos. parallel gi wire 6 swg after providing, fabrication and fixing of guarding angle and fabrication and fixing of x-guards (tillis) of gi wire at distance of 3 mtr., installation of extra t on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, t&p etc, required for proper completion of work. the "t" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material., dismentlling and removal of existing line from the various area, dismentlling of pole stp/pcc, back cartage, acsr weasel conductor scrap, iron scrap