Get complete information related to latest Load Break Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Load Break Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Load Break Switch Tenders.
Tender For design, engineering, manufacture, assembly, testing before dispatch, supply and delivery in well packed condition of 11 kv,800a, sc level 40ka for 1 sec loadbreakswitch panel ,scope also includes dismantling and removal of existing (old) 02nos.lbs panels of ngef make, disconnection of power cables and control cables and erection of new panels, power cable & control cable connection, bus bar connection, panel connection, testing, and commissioning, lbs shall conforms to iec62271- 102:2003 . detailed scope and gad,bom is as per attached annexures-i to iii
Tender For corrigendum : supply of outdoor type rmu11kv 630a 21ka 3sec both side extensible motorised scada compatible 2 nos loadbreakswitch and 1 no vacuum circuit breaker as per specification with metering module with bus pt auxiliary trfr batterycharger/battery ccv met
Tender For corrigendum : supply of 415v, utilization category ac23a, 630a local isolator cabinet in sheet steel enclosure complete with 630a, 3 pole loadbreakswitch. 2. shall be with side operated handle, padlocking facility, prebreak micro switch having 1no+1nc contact. 3. micro switch contacts shall be wired to 4 sq mm tb for external termination. 4. provision of padlock system having sufficient space to lock the isolator at off position by minimum two agencies at a time. 5. complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. detachable bottom gland plate for entry of cables from bottom. 7. front door shall be hinged and inter-locked with the isolator in 'on' position. the front door should have a minimum 3 mm thickness perspex/triplex window for observation of position of contacts. 8. isolator should confirm to iec 60364 standard. 9. the dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. isolator cabinet should be provided with rain canopy. 11. any isolator parts should not be made of aluminium/aluminium alloy. 12. isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as ip-55. 13. provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. all hardware used in isolator cabinet shall be corrosion resistant. 15. minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. cabinet should be painted with alkaline resistant epoxy paint. 17. isolator cabinet shall have provision for earthing at two separate and distinct points. 18. each isolator cabinet should be supplied with panel keys., push button station specification: 1. pbs made of 2mm sheet steel enclosure with rain canopy, protection: ip-65. 2. 01 no. of green colour start pb with 1no+1nc contacts, 01 no. of red colour stop pb with 1no+1nc contacts, 01 no.of increase pb with 1no+1nc contacts <(>&<)> 01 no.of decrease pb with 1no+1nc contacts. one emergency stop push button with 1no+1nc contacts (push to lock type) shall be provided. size of each push button is of 22.5mm diameter. inscription plate for all push buttons. 3. pb shall be wired with 2.5 sq.mm. copper wire to 40 nos. serially numbered terminal blocks (tb) of elmex make having tb-5-6, 7-8, 11-12, 13-14 <(>&<)> 17-18 shorting link. 4. two nos. of cut out of size 72x72 mm for ammeter and rpm meter shall be provided. 5. 'on','off' <(>&<)> 'trip' indication led lamps in red, green <(>&<)> amber colour respectively with inscription plate to be provided. 6. all push buttons, elements, led lamps <(>&<)> cutout for ammeter <(>&<)> rpm meter shall be on the hinged door of the pb station. 7. pb station shall be weather proof, neoprene rubber gasket suitable for outdoor application. 8. 2nos. of earthing studs to be provided. 9. left side hinged door shall be provided with flexible braided copper earthing. 10. pbs shall have 04 nos. of corrosion free bracket suitable to fix on vertical surface. 11. detachable gland plate to be provided. 12. the push button shall be painted with one coat of red oxide primer <(>&<)> two coats of zinc chromate primer and finally finished with stoving enamel grey paint. 13. the push button station shall be generally in line of enclosed drawing (fig-2). 14. party to submit the drawing along with the offer for technical scrutiny.
Tender For supply, delivery, commissioning and testing of 3 phase, 11kv/0.433 kv, 50hz, 160kva copper wound, oil colled outdoor distribution transformer, 11kv, 95sqmm, 3 phase, 4 core aliminium armoured, lt supply distribution control panel, 11kv, 630 amps, 3 phase lbs (loadbreakswitch), remoured power cables, ci earthing necessary accessories for improvement of 3 phase incoming voltage supply to the inline booster, tanker filling stations at kondapur, white field in white field section of kondapur sub division-i under operation and maintenance division xv, durgamcheruvu.