Get complete information related to latest Load Break Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Load Break Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Load Break Switch Tenders.
Tender For corrigendum : instruments - adapter for ultrasound digital fetal doppler, 1 no., 4, adult colonoscope, 1 no., 8, aluminum walker adjustable, 1 no., 12, artery forcep 6" curved, 1 no., 16, autoclave vertical: model : ac123 , lab tech -should be fully automatic vertical autoclave for total destruction of all living microorganisms-pressure adjustable from 10psi to 20psi with an accuracy of +/- 1 to 3 psi, with automatic pressure control switch-outer and inner chamber made up of stainless steel-size of the inner chamber:- 50 x 75 cm (diameter x depth)-should be providing 2 carriers of stainless steel. size of the carriers should be 35-40 x 30-35 cm ( x d)-should be provided with silicon/ rubber/ neoprene gasket-lid should be stainless steel and should be fitted with pressure gauge safety valve manual exhaust valve vacuum breaker ports of calibration check-all the hinges should be of stainless steel-should be provided with stainless steel heated cover stand-drain valve at bottom for draining the water-electrically heated-micro processor controller based system to provide digital display of cycle processes like temperature, pressure-should be provided with low water level alarm and cut off-automatic pressure control switch- to cut off the current from the heating elements, when the desired/ set pressure value level is attained inside the chamber and restarts the mechanism once the pressure inside the chamber falls from the desired level-should be fixed with chart and data recorder-iso/ ce marked -should provide test certificates, calibration certificate and traceability certificates for temperature and pressure gauges-the downtime of the equipment must not be more than 10 days annually and system must be made functional within 48 hours of breakdown and in case of such incident the period of breakdown will not be counted while calculating warranty or cmc period. if the downtime during any year is more than 10 days a penalty at the rate of 0.1percent of the cost of the equipment will be levied for each extra day of downtime.-operation manual with user demonstration video cd (with sop in guajarati), 1 no., 20, b.p. instrument digital, 1 no., 24, binocular microscope, 1 no., 28, bolster size large, 1 no., 32, bp instrument (mercury), 1 no., 36, c p chair (wooden + metal), 1 no., 40, centrifuge machine, 24 tube digital display & 5000 rpm, 1 no., 44, chital forcep 10", 1 no., 48, cold light source cable, 1 no.
Tender For microprocessor based agent release panel. as per following specifications: 1) fas-nap contr ol panel with isolator module and relay trigger unit- control by manual input with breaker switch operated e lectric solenoid valve npt normally closed nc direct action ac 220v for varied fluids (2w160-15 1/2") the direct-acting type diaphragm structure without pressure to open, to extend the using field using the plate d iaphragm structure for opening and closing. operating pressure: 0kg/cm2 to 10kg/cm2. medium: temperat ure: -5c to + 80c; type: normally closed, operates on 220 vac supply battery backup with built in chargin g, 16 x 2 lcd dot matrix display evacuate and key pad enable, disable facility. low battery visual warning with audible tone, relay output for actuators, provision for remote fire with audio / visual indications. com patible to all types of conventional detectors, zone disable (isolation) facility with loop voltage cut off, rese ttable 24 vdc output for 4 wire detectors, three 24v sounder output (fire, after cross zone, after gas relea se), two mode operation facility (auto / manual). programmable solenoid output with on and off timer. pr ogrammable main / standby cylinder output facility, gas inhibit and instant release facility. manual gas rel ease with or without timer. actuator pressure low sensing facility, rs 485 output for repeater. qty - 2 nos/s et. detailed specification and diagram as per annexure attached. make: re-120gr agent release panel or equivalent. [ warranty period: 30 months after the date of delivery ]
Tender For supply of set of rotary switch (04 item & 06 nos): failure mode operation abb doc no hbtb 58580 r1032 spec no clw/es/3/0068 alt c or latest with reference date as tender closing date qty 01 each , bogie cut-out switch abb doc no hbtb58580 r1022 spec no clw/es/3/0068 alt c or latest wit h reference date as tender closing datet= 01 each, vigilance device cut-off switch abb doc no hbt b585580 r0034 spec no. clw/es/3/0068 alt c or latest with reference date as tender closing date, qty 02 each & switch cab heater/fan abb doc no hbtb585580 r5022 or latest with reference date as ten der closing date to specn. no. clw/s/3/0108 or latest with reference date as tender closing date , qty 02 each [ warranty period: 30 months after the date of delivery ]
Tender For supply of oil filter safari storme , rectifier plate tatra , regulator assy tatra , battery cut off switch tatra , selector switch tatra , ignition switch tatra , oil pressure switch tatra , sprinkle motor tatra , sr 40 24 v tatra , control valve tatra , field coil tatra , fuel filter , water seperator , air filter safari storme , pressure plate , clutch plate , clutch bearing , outer handle , door lock , circuit breaker , water pump , fuel hose , hose ptfe 6x 400 , hose 6x 250 , spring tube , line rubber hose , fuel pipe line feed , clutch booster , line pressure pipe , brake fluid pipe , chain sprocket set , head gasket
Tender For tender for supply of tube , part no 130ph0229 , tube , part no 130ph02665 , scrpr belt auto wpr cum dst colctr , 1200m , cabin fan 24v d.c , part no 925pp01026 , cabin fan 12v , part no224250000002 , battery cut off switch , part no vd2689 , air pressure horn 24v r-35 , part no81851313