Tender For corrigendum : tender for supply of equipment design erection tetsing and commissioning for sop to 4g bsnl tower authority by providing single phase lt line at lagga chalga along with augmentation of existing dtr under esd chamba no ii - supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, supply of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. ltdistributionpanel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, erection of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. ltdistributionpanel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, mannual carriage of existing & new transf.(25 & 63 kva) 2.00 km back to store, supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96 /24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint
Tender For maintenance and upgradation of existing automatic starter panel and motorised valves system in different pump houses, repair / replacement of old unserviceable fan and geysers and repair/ maintenance of lightning protection system in different bldgs
Tender For repair/ maint of ltdistributionpanels, lt cables and external street lights incl other mechanical equipments allied works and repair maint of various type diesel generator set at dpl complex, mayur vihar pocket-1 (restricted area) and repair/ maint of lt cables,
Tender For removing, shifting and re-erection the electrical substation equipments from 6th berth s s to proposed location thereof inside cargo jetty area - removing & shifting of the following equipments as per tech spec. no:-1, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit., ltpanel ( way-15), re-erection, testing & commissioning of the following equipments as per tech. spec. no. 2, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit, supply at site 3 core armoured ht aluminium conductor xlpe cable of 11 kv grade, following rating of the as per technical specification no. 3 a). 3c x 150. sq. mm., supply at site 4 core armoured lt aluminium conductor xlpe cable of 1.1 kv grade, following rating of the as per technical specification no. 4 a) 3.5c x 300 sq. mm., supply, installation testing & commissioning at site of following 11-way lt load point panel (as per proven design) as per technical specification no. 511 ways {2 i/c, i changeover (bus coupler), 8 o/g}., laying ht/lt armoured aluminium conductor cable 3.5/4 core up to 35 sq. mm. to 150 sq. mm. as per technical specification no. 6, through hdd, with hdpe heavy duty pipe., in existing rcc trench, hard & soft soil, supply at site following way ltdistributionpanel (as per proven design) as per technical specification no. 715 ways (2 i/c, 1 bus coupler, 12 o/g)., installation, testing & commissioning of ltdistributionpanel as per technical specification no. 8, providing & connecting following type of earth wire from earth station to equipment as per requirement as per tech. spec. no. 9, 25 x 3 mm. copper strip, 25 x 3 mm. hot dip gi strip., 8 swg gi earthing wire, supply & preparation of earthing station, tfc, chemical treated back filled compound earthing system as per technical specification no. 10a) pipe-in-pipe 50-60 mm. dia. gi type 3 mtr. depth, for transformer body earth, maintenance free, supply of 3 phase 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 11, installation, testing & commissioning of 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 12, supply of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 13, fixing of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 14, supply of following type of mcb as per technical specification no. 15, 40a tpn mcb with 10ka breaking capacity, 32a sp mcb with 10ka breaking capacity, fixing of tpn/sp mcbs with 10 ka breaking capacity as per technical specification no. 16, providing & fixing of surface wiring with 2 x 2.5 sq. mm. copper conductor with pvc insulated (single phase and neutral) for single phase sub-circuit from the db/mcbs to the switch board as per technical specification no. 17, providing and fixing surface wiring with 1.5 sq. mm. copper conductor for light /tube point with pvc insulated single core standard copper conductor wire as per technical specification no. 17, providing and fixing surface wiring for 20a & 10a, 240 volt, 50hz power point as per technical specification no. 19, supply & installation of surface mounted 20 watt led tube light luminary complete with batten as per technical specification no. 20, supply at site 300mm sweep exhaust fan as per technical specification no. 21, fixing of 300mm sweep exhaust fan as per technical specification no. 22, supply of heat shrink straight through joint kit for 11kv, 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 23, fixing the heat shrink straight through joint kit for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no.24, supply of heat shrink long sleeve & boat, suitable for rmu end termination kit (indoor type) for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 25, fixing of heat shrink long sleeve & boat, suitable
Tender For ca no ge(u)/chm-56/2024-25 special repair for replacement of ltpanel soft starter flow meter and connected item at water supply installation under ge (u) chandimandir
Tender For supply of installation of ltdistributionpanel - supply and installation of ltpanel in the central block electrical power distribution room , supply and installation of lt distibution panel for production shop machines power supply , supply and installation of ltpanel for training workshop machines distribution power supply , upgradation of existing fan and lighting power suppply distributionpanels of ctr administration building, traiing and production workshop and central block training lab , supply and installation of ltpanel in gen set room for maintenance, ppc, main store including raw material store power hacksaw, welding work shop , supply and installation of lt distibution panel in gen set room for generator and main incoming power supply distribution
Tender For corrigendum : annual maint and repair of pump set, borewell, ltpanel, apfc panel, starter and cleaning of underground sumps and overhead reservoirs at nasirabad mil stn under ge nasirabad
Tender For providing materials for watersupply items of malalakere gp davanagere dist. - mains wire //ana gp, panel board items //ana gp, cable 4mm //ana gp, pump 18 stage //ana gp, pump 16 stage //ana gp, pump 14 stage //ana gp, pump 12 stage //ana gp, moter 10hp //ana gp, moter 7.5hp //ana gp, moter 6hp //ana gp, bar casing up //gp, bar casing //gp, steeg box //gp, panel bourd //gp, nrv 2 g a //gp, puc 63 m m threeded elbow //gp, puc cap 25 m m //gp, puc cap 75 m m //gp, puc cap 63 m m //gp, motor 6 h p 10 stage //gp, motar cail //gp, elbow 1/2 g a //gp, caller 1/2 g a //gp, nipple 1/2 g a 2 feet //gp, nipple 1/2 g a 1 feet //gp, elbow 3/4 g a //gp, caller 3/4 g a //gp, nipple 3/4 g a 2 feet //gp, nipple 3/4 g a1 feet //gp, electrical tape//gp, motor 7.5 15 stage //gp, motor 7.5 12 stage//gp, realy //gp, volto meter //gp, hamse meter //gp, starter //gp, praventer //gp, auto stater //gp, pipe 2 g a //gp, caller 2 g a //gp, nipple 2 g a feet //gp, bend 2 g a //gp, cabel 4 sq //gp, xcet blade //gp, selvent //gp, puc tee 25 mm //gp, puc tee 75 mm //gp, puc tee 63 mm //gp, puc elbow 75 mm //gp, puc elbow 63 mm //gp, puc elbow 25 mm //gp, puc caller 75 mm //gp, puc caller 63 mm //gp, puc caller 25 mm //gp, repair coupler 110 mm //gp, repair coupler 90 mm//gp, repair coupler 75 mm //gp, repair coupler 63 mm //gp, puc ballwall 75 mm //gp, puc ballwall 63 mm //gp, puc ballwall 20 mm //gp, puc ballwall 25 mm //gp, puc pipe 110 mm //gp, puc pipe 90 mm //gp, puc pipe 75 mm //gp, puc pipe 63 mm //gp, puc pipe 50 mm //gp, puc pipe 40 mm //gp, puc pipe 32 mm //gp, puc pipe 25 mm //gp, puc pipe 20 mm //gp